Fluoroscopy Exam Questions Complete Verified Solutions 2025 Update Total filtration permanently required in the useful fluoroscopic beam should not be less than - Answers - 2.5mm Aluminum If X-ray source is below the table, useful beam exposure must be measured at what distance above the table top - Answers - 30 cm Table top exposure rates for units without auto exposure control must be measured every - Answers - 3 years Dark adaptation for the eye takes how long - Answers - 30 minutes Target-to-tabletop distance must be greater than and should be greater than... - Answers - 12 and 18 inches Integration time for brain to recognize an object - Answers - 0.2 seconds Most scatter occurs at which direction from the primary beam - Answers - 135 degrees mA setting for spot filming where a spot film camera is not used - Answers - 150 mA Greatest dose to the patient comes from spot filming cameras using this film size - Answers - 105 mm SI unit analogous to the rad is - Answers - Gray _________ is a variation in density resulting from the random spatial distribution of quanta. - Answers - Quantum sink SI unit analogous to the rem - Answers - Sievert (unit) Exposure reduction of .25 mm lead - Answers - 97% Scattered radiation received is proportional to - Answers - Dose received by the patient Most effective medium for static viewing in terms of reducing patient dose - Answers - Video disc recorder Contrast of the image intensifying tube is measured by - Answers - conversion factor maximum magnification for cinefluorography is done via which method - Answers - total over framing Ratio of photons that leave the output phosphor to the number of Xray photons that strike the input phosphor - Answers - Flux gain Half value layer determines which characteristic of the Xray - Answers - Xray quality Ability to distinguish separate objects in line pairs per mm - Answers - Resolving power The portion of the image intensifier responsible for magnification - Answers - electrostatic lenses resolution of a 9 inch image intensifier tube - Answers - 3.5 line pairs per millimeter light photons intercepting when electrons strike a fluorescent screen forms a... - Answers - Real image Fluoro with a grid in place affects exposure rates how - Answers - 1.5-2 x higher Greatest radiosensitivity of fetus occurs when - Answers - 2-8 weeks gestation The quantity of the beam is controlled by which unit of measurement - Answers - miliamperage Which fluoroscopic method gives patient dose reduction of up to to 95%? - Answers - video disc recorder 100erg/gram is equivalent to? - Answers - 1 rad Fluoro units with AECs or CINE cameras must have physicist calibration how often - Answers - every year Which imaging modality has the best resolution - Answers - Radiograph Compared to the input phosphor, the image output phosphor is... - Answers - Smaller and brighter As spot film size increases, what happens to the patient dose? - Answers - Patient dose increases Unit used to specify the quality of an X-ray beam - Answers - HVL cycles per time unit in a TV camera is known as... - Answers - bandwidth types of pick-up tubes - Answers - plumicon, vidicon, orthicon TV camera element which converts light to an electric signal - Answers - Pickup Output intensity is measured in... - Answers - mR or R Brightness ratio of the periphery to the center of the output screen is termed: - Answers - Contrast How is resolving power measured? - Answers - Line pairs per milimeter Which factors produce a brighter image at the output phosphor? - Answers - Flux gain and minification What type of TV system has all its signals carried through cables? - Answers - Closed circuit TV Output intensity of a tube is measured in... - Answers - Miliroentgens Electronic intensification occurs when... - Answers - Electrons are moved at high speed from photocathode to output phosphor

Montrer plus Lire moins
Établissement
Fluoroscopy
Cours
Fluoroscopy









Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
Fluoroscopy
Cours
Fluoroscopy

Infos sur le Document

Publié le
25 mars 2025
Nombre de pages
11
Écrit en
2024/2025
Type
Examen
Contenu
Questions et réponses

Sujets

Aperçu du contenu

Fluoroscopy Exam Questions Complete
Verified Solutions 2025 Update
Total filtration permanently required in the useful fluoroscopic beam should not be less
than - Answers -✔✔ 2.5mm Aluminum

If X-ray source is below the table, useful beam exposure must be measured at what
distance above the table top - Answers -✔✔ 30 cm

Table top exposure rates for units without auto exposure control must be measured
every - Answers -✔✔ 3 years

Dark adaptation for the eye takes how long - Answers -✔✔ 30 minutes

Target-to-tabletop distance must be greater than and should be greater than... -
Answers -✔✔ 12 and 18 inches

Integration time for brain to recognize an object - Answers -✔✔ 0.2 seconds

Most scatter occurs at which direction from the primary beam - Answers -✔✔ 135
degrees

mA setting for spot filming where a spot film camera is not used - Answers -✔✔ 150 mA

Greatest dose to the patient comes from spot filming cameras using this film size -
Answers -✔✔ 105 mm

SI unit analogous to the rad is - Answers -✔✔ Gray

_________ is a variation in density resulting from the random spatial distribution of
quanta. - Answers -✔✔ Quantum sink

SI unit analogous to the rem - Answers -✔✔ Sievert (unit)

Exposure reduction of .25 mm lead - Answers -✔✔ 97%

Scattered radiation received is proportional to - Answers -✔✔ Dose received by the
patient

Most effective medium for static viewing in terms of reducing patient dose - Answers -
✔✔ Video disc recorder

, Contrast of the image intensifying tube is measured by - Answers -✔✔ conversion factor

maximum magnification for cinefluorography is done via which method - Answers -✔✔
total over framing

Ratio of photons that leave the output phosphor to the number of Xray photons that
strike the input phosphor - Answers -✔✔ Flux gain

Half value layer determines which characteristic of the Xray - Answers -✔✔ Xray quality

Ability to distinguish separate objects in line pairs per mm - Answers -✔✔ Resolving
power

The portion of the image intensifier responsible for magnification - Answers -✔✔
electrostatic lenses

resolution of a 9 inch image intensifier tube - Answers -✔✔ 3.5 line pairs per millimeter

light photons intercepting when electrons strike a fluorescent screen forms a... -
Answers -✔✔ Real image

Fluoro with a grid in place affects exposure rates how - Answers -✔✔ 1.5-2 x higher

Greatest radiosensitivity of fetus occurs when - Answers -✔✔ 2-8 weeks gestation

The quantity of the beam is controlled by which unit of measurement - Answers -✔✔
miliamperage

Which fluoroscopic method gives patient dose reduction of up to to 95%? - Answers -
✔✔ video disc recorder

100erg/gram is equivalent to? - Answers -✔✔ 1 rad

Fluoro units with AECs or CINE cameras must have physicist calibration how often -
Answers -✔✔ every year

Which imaging modality has the best resolution - Answers -✔✔ Radiograph

Compared to the input phosphor, the image output phosphor is... - Answers -✔✔
Smaller and brighter

As spot film size increases, what happens to the patient dose? - Answers -✔✔ Patient
dose increases
12,85 €
Accéder à l'intégralité du document:

Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien


Document également disponible en groupe

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
Stuviaascorers University of Washington
S'abonner Vous devez être connecté afin de pouvoir suivre les étudiants ou les formations
Vendu
345
Membre depuis
2 année
Nombre de followers
185
Documents
10034
Dernière vente
3 jours de cela
StuviaAscorers | Top Study Notes & Exam Solutions

Stuviaascorers – Your #1 Source for Top-Quality Study Materials! Struggling with exams? Stuviaascorers has got you covered! I provide expertly crafted study notes, summaries, past papers, and exam-ready answers to help you pass with flying colors. My materials are designed for clarity, accuracy, and success—so you can study smarter, not harder! Why Choose My Study Materials? Well-structured & easy to understand – No fluff, just what you need! Exam-focused & high-scoring content – Get straight to the point! Accurate answers & clear explanations – Learn with confidence! Save time & boost your grades – Study efficiently! Don’t leave your success to chance! Browse my documents and start acing your exams today!

Lire la suite Lire moins
3,8

64 revues

5
30
4
11
3
11
2
2
1
10

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions