ARRT MRI REGISTRY EXAM Complete Questions and Correct Answers (2024/2025) FINAL EXAM Already Graded Which of the following parameter adjustments will LENGTHEN scan time in an MR pulse sequence? I. Decrease TR II. Increase TR III. Increase ETL IV. Decrease ETL V. Decrease NEX VI. Increase NEX VII. Enable Half-fourier VIII. Increase parallel imaging factor IX. Decrease parallel imaging factor X. Enable anti-aliasing - ANSWER II, IV, VI and IX Which of the following parameter adjustments help to improve SNR in an MR image? I. Increase TR II.Reduce Phase Matrix III. Reduce Pixel Size IV. Increase FOV V. Reduce rBW VI. Increase rBW VII. Increase NSA VIII. Decrease NSA IX. Increase ETL X. Decrease ETL - ANSWER I, II, IV, V, VII and X In a fast spin echo sequence with a 25 cm FOV, 224 x 320 matrix, TR 2500, 100 TE, 3mm slice thickness, 12 ETL and 4 NEX, the scan time would be: A. 2 minutes 6 seconds B. 3 minutes 7 seconds C. 3 minutes 11 seconds D. 4 minutes 27 seconds E. 4 minutes 44 seconds - ANSWER 3 minutes 7 seconds The phase encoding step is performed: A. During frequency encoding B. In place of frequency encoding C. Prior to frequency encoding D. Following frequency encoding - ANSWER Prior to frequency encoding Permanent magnets with a vertical magnetic field use surface coils that are: A. Phased array B. Linear C. Quadrature D. Solenoids - ANSWER Solenoids Gradient echo sequences can yield either T1 or T2* characteristics, with influences caused by all of the following EXCEPT: A. Chemical shift B. Inhomogeneity C. Susceptibility D. Inversion time - ANSWER Inversion time In what orientation would a tear of the collateral ligaments of the knee be best visualized? A. Sagittal B. Axial C. Transverse D. Coronal E. None of the above - ANSWER Coronal RF energy used in MRI is classified as: A. Low energy, nonionizing radiation B. Low energy, ionizing radiation C. High energy, nonionizing radiation D. High energy, ionizing radiation - ANSWER Low energy, nonionizing radiation On T1 weighted images of the spine, the CSF (cerebrospinal fluid) appears: A. Isointense to the spinal cord B. Hypointense to the spinal cord C. Hyperintense to the spinal cord D. None of the above - ANSWER Hypointense to the spinal cord Single order gradient moment nulling does not compensate for: A. Constant velocity flow B. Accelerated flow C. Reverse flow D. B and C - ANSWER B and C The gradient rise time is defined as the: A. Time it takes longitudinal magnetization to regrow B. Time between TI and initial RF pulse C. Speed rate of ascent or descent of a gradient from zero to its maximum amplitude D. Time it takes for the gradient to reach its full amplitude - ANSWER Time it takes for the gradient to reach its full amplitude In an MRA sequence, the removal of signal from vessels is accomplished by: A. Spectral presaturation B. Spatial presaturation C. Gradient moment nulling D. B and C E. None of the above - ANSWER Spatial prostration CSF suppression is performed with which type of technique? A. FLAIR B. STIR C. SPGR D. FISP - ANSWER FLAIR Magnetic field inhomogeneity is expressed in: A. Watts per kilogram B. Gauss per centimeter C. Parts per million D. Tesla per meter - ANSWER Parts per million

Montrer plus Lire moins
Établissement
ARRT MRI REGISTRY
Cours
ARRT MRI REGISTRY











Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
ARRT MRI REGISTRY
Cours
ARRT MRI REGISTRY

Infos sur le Document

Publié le
17 novembre 2024
Nombre de pages
31
Écrit en
2024/2025
Type
Examen
Contenu
Questions et réponses

Sujets

Aperçu du contenu

ARRT MRI REGISTRY EXAM
Complete Questions and Correct Answers
(2024/2025) FINAL EXAM
Already Graded
Which of the following parameter adjustments will LENGTHEN scan time in an
MR pulse sequence?
I. Decrease TR
II. Increase TR
III. Increase ETL
IV. Decrease ETL
V. Decrease NEX
VI. Increase NEX
VII. Enable Half-fourier
VIII. Increase parallel imaging factor
IX. Decrease parallel imaging factor
X. Enable anti-aliasing - ANSWER ✔ II, IV, VI and IX

Which of the following parameter adjustments help to improve SNR in an MR
image?
I. Increase TR
II.Reduce Phase Matrix
III. Reduce Pixel Size
IV. Increase FOV
V. Reduce rBW
VI. Increase rBW
VII. Increase NSA
VIII. Decrease NSA
IX. Increase ETL
X. Decrease ETL - ANSWER ✔ I, II, IV, V, VII and X

In a fast spin echo sequence with a 25 cm FOV, 224 x 320 matrix, TR 2500, 100
TE, 3mm slice thickness, 12 ETL and 4 NEX, the scan time would be:
A. 2 minutes 6 seconds
B. 3 minutes 7 seconds
C. 3 minutes 11 seconds
D. 4 minutes 27 seconds

,E. 4 minutes 44 seconds - ANSWER ✔ 3 minutes 7 seconds

The phase encoding step is performed:
A. During frequency encoding
B. In place of frequency encoding
C. Prior to frequency encoding
D. Following frequency encoding - ANSWER ✔ Prior to frequency encoding

Permanent magnets with a vertical magnetic field use surface coils that are:
A. Phased array
B. Linear
C. Quadrature
D. Solenoids - ANSWER ✔ Solenoids

Gradient echo sequences can yield either T1 or T2* characteristics, with
influences caused by all of the following EXCEPT:
A. Chemical shift
B. Inhomogeneity
C. Susceptibility
D. Inversion time - ANSWER ✔ Inversion time

In what orientation would a tear of the collateral ligaments of the knee be best
visualized?
A. Sagittal
B. Axial
C. Transverse
D. Coronal
E. None of the above - ANSWER ✔ Coronal

RF energy used in MRI is classified as:
A. Low energy, nonionizing radiation
B. Low energy, ionizing radiation
C. High energy, nonionizing radiation
D. High energy, ionizing radiation - ANSWER ✔ Low energy, nonionizing
radiation

On T1 weighted images of the spine, the CSF (cerebrospinal fluid) appears:
A. Isointense to the spinal cord
B. Hypointense to the spinal cord

,C. Hyperintense to the spinal cord
D. None of the above - ANSWER ✔ Hypointense to the spinal cord

Single order gradient moment nulling does not compensate for:
A. Constant velocity flow
B. Accelerated flow
C. Reverse flow
D. B and C - ANSWER ✔ B and C

The gradient rise time is defined as the:
A. Time it takes longitudinal magnetization to regrow
B. Time between TI and initial RF pulse
C. Speed rate of ascent or descent of a gradient from zero to its maximum
amplitude
D. Time it takes for the gradient to reach its full amplitude - ANSWER ✔ Time it
takes for the gradient to reach its full amplitude

In an MRA sequence, the removal of signal from vessels is accomplished by:
A. Spectral presaturation
B. Spatial presaturation
C. Gradient moment nulling
D. B and C
E. None of the above - ANSWER ✔ Spatial presaturation

CSF suppression is performed with which type of technique?
A. FLAIR
B. STIR
C. SPGR
D. FISP - ANSWER ✔ FLAIR

Magnetic field inhomogeneity is expressed in:
A. Watts per kilogram
B. Gauss per centimeter
C. Parts per million
D. Tesla per meter - ANSWER ✔ Parts per million

During dynamic enhanced imaging for vasculature or visceral structures, contrast
is administered and k-space is filled with __________ to ensure that the contrast
enhancement is well visualized.

, A. Centric
B. Linear
C. Reverse centric
D. Reverse linear - ANSWER ✔ Centric

To produce a high quality reformatted image, the:
A. Acquisition voxel should be anisotropic
B. Acquisition voxel should be isotropic
C. NEX >4 should be utilized
D. Acquisition voxel should be rectangular - ANSWER ✔ Acquisition voxel
should be isotropic

When imaging a hemorrhagic infarct in the brain, which pulse sequence would
demonstrate the magnetic susceptibility effects better?
A. Spin echo
B. Fast spin echo
C. Inversion recovery
D. Gradient echo
E. Multi echo spin echo
F. FLAIR - ANSWER ✔ Gradient echo

Due to the lack of 180° RF refocusing pulse, the gradient echo sequence is more
susceptible to magnetic field inhomogeneities, such as hemosiderin from blood
products. The hemosiderin is highly magnetic because it is principally iron.

Which of the following sequences is the most insensitive to magnetic field
inhomogeneity?
A. RF spoiled gradient echo
B. Spin echo
C. Steady state rephased gradient echo
D. Echo planar - ANSWER ✔ Spin echo

The MRI system component that provides the ability to perform spatial encoding
is the:
A. Shim system
B. Main magnet
C. Gradient system
D. Radiofrequency system - ANSWER ✔ Gradient system
11,49 €
Accéder à l'intégralité du document:

Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
SmartscoreAaron Chicago State University
S'abonner Vous devez être connecté afin de pouvoir suivre les étudiants ou les formations
Vendu
36
Membre depuis
1 année
Nombre de followers
3
Documents
3090
Dernière vente
2 semaines de cela
SMARTSCORES LIBRARY

Get top-tier academic support for Psychology, Nursing, Business, Engineering, HRM, Math, and more. Our team of professional tutors delivers high-quality homework, quiz, and exam assistance—ensuring scholarly excellence and grade-boosting results. Trust our collaborative expertise to help you succeed in any course at U.S.A Institutions.

3,8

4 revues

5
2
4
1
3
0
2
0
1
1

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions