Worn motor bearings are most to result in a(n)___. continuous overload A high-level short circuit current may exceed ___. 50,000A` Accidental contact between an electrical conductor and a grounded enclosure is called a(n)___. ground fault Most arcing faults begin as ___. ground faults A plug fuse with a hexagonal cap has a maximum amperage rating of ___. 15A Under normal operation and at currents near its ampere rating, a fuse operates as a ___. conductor UL classifies low-voltage fuses as those operating at ___. 600v or less A standard circuit breaker frame size is ___. 100A The interrupting capacity of a circuit breaker is based on its rated ___. voltage A feeder circuit with no motor load has a continuous load of 10A and a noncontinuous load of 5A. The feeder overcurrent protective device should be sized at ___. 17.5A 10A(1.25)+5A=17.5A The full-load current rating of a 300kVA, three-phase transformer operating at 480v is ___. 361A 300kVA(1000) 480v(1.73) = 361 If a circuit breaker has tripped and stays on for a limited time before tripping again after being reset, the problem is least likely to be a(n) ___. ground fault Which of the following is true with regard to fuses? Fuseholder clips that have lost their spring cannot be repaired with pliers; they must be replaced. Which of the following best describes the maximum short circuit current that a fuse or circuit breaker will safely interrupt? AIC A plug fuse is typically used in a ____. branch circuit A 600v fuse can be used in ___. A 240v circuit A type of fuse with a grooved ring in one ferrule is a Type ___. R Each of the following is a basic factor to consider when applying any fuse, except ___. manufacture's brand name For proper coordination, the total clearing time of any downstream protective device must be below a curve representing which percentage of the minimum melting curve of the fuse being applied? 75% The minimum interrupting rating of branch circuit listed fuses is ___. 10,000A The minimum voltage rating of branch circuit fuses is ___. 125v All of the following are classifications of medium-voltage fuses, except____. proportion fuses An explosion fuse is best described as a ___. vented fuse in which the explosion effect of gases produced by the arc and lining of the fuseholder, either alone or aided by a spring, extinguishes the arc The maximum fuse size for a single-element, non-time-delay fuse serving a 10hp, three-phase motor is ____. 100A One characteristic of a dual-element, time-delay fuse is that it ___. provides backup protection if the other protective device fail to operate When a common circuit breaker trips, the handle is in the ___. middle position A 60A circuit breaker has a frame size of __. 100A When circuit breakers are classified as a 100A through 2,000A frames, these numbers are normally referred to as the ___. frame size A feeder circuit with no motor load has a continuous load of 15A and a noncontinuous load of 10A. The feeder overcurrent device should be sized at ___. 28.75A 15(1.25)+10A=28.75A The full-load current rating of a 225kVA, three-phase transformer operating at 240v is ____. 542A 225kVA(1000) 240v(1.73) = 542A The full-load current rating of a 150kVA, three-phase transformer operating at 240v is ___. 362 150kVA(1000) 240v(1.73) = 362 The let-through short circuit current of a 500kVA, 120/208v three-phase transformer is ___. 69,444A A circuit breaker that trips instantly or fails to reset is most likely the result of ___. a short circuit A short circuit current is one that flows outside the normal conducting paths and may be either line-to-line or ____. line-to-ground The AIC rating of a circuit breaker or fuse is the _____. maximum fault current that the breaker will safely interrupt If a fault current exceeds the interrupting rating, what can happen? The protective device can be damaged or destroyed; such current can also cause severe damage to equipment and injure personnel. Name the factors that must be considered when calculating the required interrupting capacity of an overcurrent protective device . overcurrent protective device, total impendence, equipment short circuit current ratings The two most common voltage ratings for low-voltage power distribution fuses are ___. 250v or 600v True or False? The voltage rating of a fuse can be greater than the circuit voltage. True: For example, a 600v fuse can be used in a 240 circuit. True or False? The rating that defines the capacity of a protective device to maintain its integrity when reacting to fault currents is termed its voltage rating. False: its is termed "Interrupting rating" Why is the coordination of protective devices important? They prevent system power outages and/or blackouts caused by overcurrent conditions Class H fuses have an interrupting rating of ____. 10,000A The basic factors that must be considered when applying any fuse include the _____. voltage, continuous current-carrying capacity, Interrupting rating True or False: Current-limiting fuses produce arc voltages that exceed the system voltage. True Circuit breakers are grouped for identification according to given current ranges. Name them. 15A-100A

Montrer plus Lire moins
Établissement
Cours









Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
Cours

Infos sur le Document

Publié le
25 septembre 2023
Nombre de pages
6
Écrit en
2023/2024
Type
Examen
Contenu
Questions et réponses

Sujets

13,11 €
Accéder à l'intégralité du document:

Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien


Document également disponible en groupe

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
BRAINBOOSTERS Chamberlain College Of Nursing
S'abonner Vous devez être connecté afin de pouvoir suivre les étudiants ou les formations
Vendu
654
Membre depuis
2 année
Nombre de followers
250
Documents
22740
Dernière vente
12 heures de cela

In this page you will find all documents , flashcards and package deals offered by seller BRAINBOOSTERS

4,5

339 revues

5
264
4
30
3
21
2
5
1
19

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions