Containing a plumbing system from the public water supply requires backflow protection at the _______? A. Appliance or fixture B. Building foundation C. Irrigation system D. Service Connection E. Sprinkler riser - ANSWERService Connection Backflow preventer manufacturers recommend that assemblies be field-tested annually and when_____? A. Installed B. Moved C. Repaired or Installed D. Shut down E. Water suppliers provide notice - ANSWERRepaired

Montrer plus Lire moins
Établissement
Backflow Certification
Cours
Backflow certification

Aperçu du contenu

BACKFLOW PREVENTION PRACTICE
EXAM CORRECT 100%
Containing a plumbing system from the public water supply requires backflow protection
at the _______?
A. Appliance or fixture
B. Building foundation
C. Irrigation system
D. Service Connection
E. Sprinkler riser - ANSWERService Connection

Backflow preventer manufacturers recommend that assemblies be field-tested annually
and when_____?
A. Installed
B. Moved
C. Repaired or Installed
D. Shut down
E. Water suppliers provide notice - ANSWERRepaired or Installed

A differential pressure gauge reading of 0.2 psid is represented on water column sight
tube by _____?
A. 1/16 in. (0.16 cm)
B. 1/2 in. (1.3 cm)
C. 2 in. (5.1 cm)
D. 3.5 in. (8.9 cm)
E. 5.5 in. (14 cm) - ANSWER5.5 in. (14 cm)

Pollution of a public water supply suggests the substance in the water is ____?
A. Aesthetically bad
B. Biological with virus only
C. Lowering the pH below 1.4
D. Radiological
E. Toxic - ANSWERAesthetically bad

Backsiphonage may occur when the pressure inside copper tubing is ____?
A. Greater than atmospheric pressure
B. Greater than barometric pressure
C. Greater than 0 gauge pressure
D. Less than absolute pressure
E. Less than atmospheric pressure - ANSWERLess than atmospheric pressure

A cross-connection may be a permanent piping arrangement or a(n) ____?
A. Backflow preventer
B. Church symbol

,C. OSHA hazardous area designation
D. Railroad and highway intersection sign
E. Temporary hose bibb connection - ANSWERTemporary hose bibb connection

The isolation of a plumbing water system hazard requires____?
A. Appliance protection
B. Building quarantine
C. High-hazard protection
D. Meter protection
E. Toxin monitoring - ANSWERAppliance protection

A direct cross-connection suggests the piping system may be subjected to ____?
A. Backpressure or backsiphonage
B. Backsiphonage only
C. Periodic inspection
D. Sustained pressure
E. Toxic materials - ANSWERBackpressure or backsiphonage

A pipe restriction's flow velocity increase may allow ____?
A. Aspiration
B. Backpressure
C. Low turbulence
D. Pressure head
E. Pressure surges - ANSWERAspiration

Water supply contamination from backflow may result in ____?
A. A bad taste
B. Coloration
C. Death
D. Odor or smell
E. Pipe wall mineral deposit flaking - ANSWERDeath

To prevent backflow, an atmospheric vacuum breaker is primarily designed to ____?
A. Allow air into the outlet piping system
B. Create an elevation loop above ground
C. Introduce head loss
D. Prevent backpressure
E. Restrict velocity - ANSWERAllow air into the outlet piping system

Atmospheric vacuum breakers will typically be located on ____?
A. Commercial irrigation systems
B. Fire-suppression systems
C. Plumbing fixtures or appliances
D. Utility storage tanks
E. Water service connections - ANSWERPlumbing fixtures or appliances

, The mechanical component of an atmospheric vacuum breaker serves as an air-inlet
valve and a ____?
A. Check valve
B. Regulating valve
C. Relief valve
D. Shut-off valve
E. Test port - ANSWERCheck valve

A deck-mounted atmospheric vacuum breaker's critical installation level is above the
outlet usage by ___?
A. 1 in. (2.5 cm)
B. 3 in. (7.6 cm)
C. 6 in. (15 cm)
D. 12 in. (30 cm)
E. 18 in. (46 cm) - ANSWER1 in. (2.5 cm)

A hose-bibb connection is required to have a permanently installed ____?
A. Atmospheric vacuum breaker
B. Backflow preventer
C. Pressure vacuum breaker
D. Shut-off valve
E. Spill-resistant vacuum breaker - ANSWERAtmospheric vacuum breaker

Atmospheric vacuum breakers must not be subject to continuous water pressure for
more than ___ hr.
A. 3
B. 6
C. 12
D. 18
E. 24 - ANSWER12

A submerged atmospheric vacuum breaker may be considered a(n) _____?
A. Backflow preventer
B. Cross-connection
C. Expensive elbow
D. Typical installation
E. Useful training photo - ANSWER. Cross-connection

Flow from the outlet of an atmospheric vacuum breaker must not reach a _____?
A. Closed tank
B. Section of straight tubing
C. Submerged inlet
D. Toxic substance
E. Valve - ANSWERValve

An atmospheric vacuum breaker is not required to have a(n) _____?

École, étude et sujet

Établissement
Backflow certification
Cours
Backflow certification

Infos sur le Document

Publié le
12 février 2026
Nombre de pages
18
Écrit en
2025/2026
Type
Examen
Contenu
Questions et réponses

Sujets

14,71 €
Accéder à l'intégralité du document:

Mauvais document ? Échangez-le gratuitement Dans les 14 jours suivant votre achat et avant le téléchargement, vous pouvez choisir un autre document. Vous pouvez simplement dépenser le montant à nouveau.
Rédigé par des étudiants ayant réussi
Disponible immédiatement après paiement
Lire en ligne ou en PDF


Document également disponible en groupe

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
shantelleG West Virgina University
S'abonner Vous devez être connecté afin de pouvoir suivre les étudiants ou les formations
Vendu
625
Membre depuis
3 année
Nombre de followers
369
Documents
18116
Dernière vente
2 semaines de cela
GOLD PREMIUM

HELLO? welcome to my store thanks for visiting this page here you are guaranteed of well revised and assured EXAMS ALL GRADED A+ thus making your education journey easy and seamless . DO NOT HESITATE TO CONTACT ME IF YOU ARE IN NEED OF ANY EXAM .I AM READY 24/7 TO ASSIST YOU ALSO REFER YOUR FRIENDS.

4,0

118 revues

5
69
4
11
3
24
2
2
1
12

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions