Rédigé par des étudiants ayant réussi Disponible immédiatement après paiement Lire en ligne ou en PDF Mauvais document ? Échangez-le gratuitement 4,6 TrustPilot
logo-home
Examen

BACKFLOW / CROSS CONNECTION TEST PRACTICE || 2026 LATEST UPDATE!!!

Note
-
Vendu
-
Pages
5
Qualité
A+
Publié le
12-02-2026
Écrit en
2025/2026

14.71 Pounds per square inch - ANSWERwhat is the means value of atmospheric pressure at sea level Backsiphonage - ANSWERA backflow condition in which the pressure in the distribution system is less than atmospheric pressure (subatmospheric) Cross Connection - ANSWERA byass arrangement or jumper connection around a backflow prevention device is considered a....

Montrer plus Lire moins
Établissement
Backflow Certification
Cours
Backflow certification

Aperçu du contenu

BACKFLOW / CROSS CONNECTION
TEST PRACTICE || 2026 LATEST
UPDATE!!!
14.71 Pounds per square inch - ANSWERwhat is the means value of atmospheric
pressure at sea level

Backsiphonage - ANSWERA backflow condition in which the pressure in the distribution
system is less than atmospheric pressure (subatmospheric)

Cross Connection - ANSWERA byass arrangement or jumper connection around a
backflow prevention device is considered a....

Both Backsiphonage and BackPressure - ANSWERA direct cross-connection is a cross
connection that is subject to ...

Pressure Vacuum Breaker - ANSWERA device designed to prevent backsiphonge,
consisting of one independently operating spring-loaded check valve and an
independently operating spring loaded air-inlet valve.

Double Check Valve Assembly - ANSWERAssembly composed of two independently
acting, approved check valves , including tightly closing resilient seated shut off valves
attached at each end of the assembly and fitted with properly located resilient seated
test cocks

False - ANSWERBackflow from a submerged inlet to a plating solution tank is
prevented only through installation of a double check valve

air gap - ANSWERThe highest possible backflow protection is provided by....

Dynamic Pressure - ANSWERthe pressure associated with the movement of a fluid

Twice the diameter of the pipe and no less than 1 inch - ANSWERAn approved air gap
shall be at what vertical distance above the overflow rim and no less than what
distance?

Absolute Pressure - ANSWERPressure measured on a scale where a perfect vacuum is
zero. th sume of gauge pressure and atmospheric pressure.

spill resistant vacuum breaker assembly - ANSWERequipped with a properly located
resilient test cock, a properly located bleed/ vent port and a tightly closing resilient
seated shot off valves attached to each end of the assembly

, Water Purveyor - ANSWERWho has the primary responsibility in cross connection
control to protect the public water supply ( containment)

True - ANSWERA reduced pressure principal is a device that can be used to protect
against pollution, contamination, back pressure and back siphonage.

Isolation - ANSWERA method of back flow prevention at the point of use of the
customer's water supply

Barometric Loop - ANSWERA vertical loop of pipe, rising to a height sufficient to
prevent back-siphonage from occurring in the potable water supply pipe. (Approximately
35 feet, depending on the weight of the atmosphere.)

15 working days - ANSWERIn Orange Cunty, a certified tester is required to submit
their test report from with in how many days of testing a backflow device?

Health and Safety Code - ANSWERWho gives the authority to LOCAL HEALTH
agencies to administer the cross connection program and tester certification program

The flood level rim of the plumbing fixture - ANSWERAn Air Gap is measured from the
exit of the piping to what?

33.9 ft - ANSWERA perfect vacuum at sea level can pull a water column approximately
how many feet?

Isolation - ANSWERBack flow prevention at the point of use is define as?

Reduced Pressure Principle Backflow Assembly - ANSWERFor Containment protection
in a high hazard situation, the minimum backflow prevention device required is

Differential Pressure - ANSWERThe difference in pressure between two locations in a
piping system

Differenteial pressure gauge - ANSWERType of equipment used to test backflow
assemblies such as RP, DC, PVB, SVB


Containment - ANSWERMethod of backflow prevention at the point of connection
(meter) of the consumers water supply

Nevada Administrative Code (NAC) 445-A - ANSWERWhat is the Legal Document in
Nevada that governs Cross Connection control and backflow prevention

The Safe Drinking Water Act ;amended 1996 - ANSWERThe Federal Guidelines that
regulate the safety of drinking water are contained in.

École, étude et sujet

Établissement
Backflow certification
Cours
Backflow certification

Infos sur le Document

Publié le
12 février 2026
Nombre de pages
5
Écrit en
2025/2026
Type
Examen
Contenu
Questions et réponses

Sujets

11,14 €
Accéder à l'intégralité du document:

Mauvais document ? Échangez-le gratuitement Dans les 14 jours suivant votre achat et avant le téléchargement, vous pouvez choisir un autre document. Vous pouvez simplement dépenser le montant à nouveau.
Rédigé par des étudiants ayant réussi
Disponible immédiatement après paiement
Lire en ligne ou en PDF


Document également disponible en groupe

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
shantelleG West Virgina University
S'abonner Vous devez être connecté afin de pouvoir suivre les étudiants ou les formations
Vendu
625
Membre depuis
3 année
Nombre de followers
369
Documents
18116
Dernière vente
2 semaines de cela
GOLD PREMIUM

HELLO? welcome to my store thanks for visiting this page here you are guaranteed of well revised and assured EXAMS ALL GRADED A+ thus making your education journey easy and seamless . DO NOT HESITATE TO CONTACT ME IF YOU ARE IN NEED OF ANY EXAM .I AM READY 24/7 TO ASSIST YOU ALSO REFER YOUR FRIENDS.

4,0

118 revues

5
69
4
11
3
24
2
2
1
12

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions