Rédigé par des étudiants ayant réussi Disponible immédiatement après paiement Lire en ligne ou en PDF Mauvais document ? Échangez-le gratuitement 4,6 TrustPilot
logo-home
Examen

BACKFLOW PRACTICE EXAM QUESTIONS & SOLUTIONS(RATED A+)

Note
-
Vendu
-
Pages
7
Qualité
A+
Publié le
12-02-2026
Écrit en
2025/2026

1) Backflow is the undesirable reversal of flow of water or other substances through a cross connection into the public water system or consumer's: - ANSWERC. Public water system or consumer's portable water system 2) An approved airgap (AG) is a physical separation between the free-flowing end of a: - ANSWERD. Potable water supply pipe line in the overflow rim of an open or non-pressurized receiving vessel 3) And indirect cross-connection is one that is subject

Montrer plus Lire moins
Établissement
Backflow Certification
Cours
Backflow certification

Aperçu du contenu

BACKFLOW PRACTICE EXAM
QUESTIONS & SOLUTIONS(RATED
A+)
1) Backflow is the undesirable reversal of flow of water or other substances through a
cross connection into the public water system or consumer's: - ANSWERC. Public water
system or consumer's portable water system

2) An approved airgap (AG) is a physical separation between the free-flowing end of a: -
ANSWERD. Potable water supply pipe line in the overflow rim of an open or non-
pressurized receiving vessel

3) And indirect cross-connection is one that is subject to what type of backflow? -
ANSWERA. Only backsiphonage

4 )Cross-connections with between the portable water piping in any piping or containers
containing substances not approved as potable water must be either eliminated or
controlled by the installation of an: - ANSWERD. Approved air gap or an approved
backflow prevention assembly

5) While testing CV #2 of a DCVA if CV #2 leaks the BAT would observe that the water
flow: - ANSWERD. Stops from the site tube at TC#4 and no differential shows on the
gauge

6) Service protection is a way to protect a public water system from contamination due
to back flow from the customer's water system by the installing an approved backflow
preventer at the: - ANSWERA. Service connection which is considered to be at or near
the water meter

7) A Washington state certified Backflow Assembly Tester is certified to: - ANSWERD.
Inspect, test and monitor backflow prevention assemblies

8) The RPBA is designed so that if the check valve leaks, the relief with valve may: -
ANSWERB. Open to discharge through the relief valve vent

9) An AG installed in lieu of an approved backflow prevention assembly must be
inspected for compliance with the definition of an improved air gap by: - ANSWERC.
Either a CCS or a BAT

10) After testing an approved backflow prevention assembly the BAT shall complete a
test report that is acceptable to the: - ANSWERC. Purveyor

11) The gauge on a differential pressure test kit indicates: - ANSWERC. psid

, 12) Loading a check valve with springs or weights: - ANSWERC. Reduces pressure
down stream of the check valve

13) If there is flow across CV#1 and through an RPBA the relief valve will not discharge
unless: - ANSWERC. The relief valve is defective

14) Microbiological contaminates entering the portible water system are always a: -
ANSWERA. High-health standard

15) All approved backflow prevention assemblies must be tested with a: - ANSWERD.
Differential pressure test kit

16) An approved backflow prevention assembly is an: - ANSWERC. RPBA, RPDA,
DCVA, DCDA, PVBA, or SVBA of make, model, and size that is approved by the DOH

17) Permanent support blocks are required under all approved backflow assemblies that
are: - ANSWERD. A large size assembly

18) A backflow assembly test report must be: - ANSWERC. Complete, accurate and
legible

19) SOV #1 of a properly installed PVBA
is reported as leaking while testing the air inlet valve if water continues to flow from: -
ANSWERC. The high-bleed valve and the differential gauge does not drop to the
opening point of the Air Inlet Valve

20) The differential pressure relief valve must discharge water to the atmosphere when
the pressure in the zone between the check valves is with in: - ANSWERB. 2 psi of the
pressure upstream of CV #1

21) The Undesirable reversal of flow of water or other substances through a cross
connection into the public water system or consumers potible water system is: -
ANSWERD. Backflow

22) While testing CV#2 of an RPBA the BAT must determine if CV#2 closes tight: -
ANSWERD. In the reverse direction of flow

23) A DCDA should not be installed: - ANSWERB. Where pressure in the water system
is greater than the assembly's maximum working water pressure

24) The contents of the backflow assembly test report completed after testing a
backflow prevention assembly installed at the water meter must meet the requirements
of the: - ANSWERD. Water purveyor

École, étude et sujet

Établissement
Backflow certification
Cours
Backflow certification

Infos sur le Document

Publié le
12 février 2026
Nombre de pages
7
Écrit en
2025/2026
Type
Examen
Contenu
Questions et réponses

Sujets

11,59 €
Accéder à l'intégralité du document:

Mauvais document ? Échangez-le gratuitement Dans les 14 jours suivant votre achat et avant le téléchargement, vous pouvez choisir un autre document. Vous pouvez simplement dépenser le montant à nouveau.
Rédigé par des étudiants ayant réussi
Disponible immédiatement après paiement
Lire en ligne ou en PDF


Document également disponible en groupe

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
shantelleG West Virgina University
S'abonner Vous devez être connecté afin de pouvoir suivre les étudiants ou les formations
Vendu
625
Membre depuis
3 année
Nombre de followers
369
Documents
18116
Dernière vente
2 semaines de cela
GOLD PREMIUM

HELLO? welcome to my store thanks for visiting this page here you are guaranteed of well revised and assured EXAMS ALL GRADED A+ thus making your education journey easy and seamless . DO NOT HESITATE TO CONTACT ME IF YOU ARE IN NEED OF ANY EXAM .I AM READY 24/7 TO ASSIST YOU ALSO REFER YOUR FRIENDS.

4,0

118 revues

5
69
4
11
3
24
2
2
1
12

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions