Rédigé par des étudiants ayant réussi Disponible immédiatement après paiement Lire en ligne ou en PDF Mauvais document ? Échangez-le gratuitement 4,6 TrustPilot
logo-home
Examen

ALASKA

Note
-
Vendu
-
Pages
8
Qualité
A+
Publié le
18-01-2026
Écrit en
2025/2026

Exam of 8 pages for the course ALASKA Mechanical Administrator Unlimited Com at ALASKA Mechanical Administrator Unlimited Com (ALASKA)

Établissement
ALASKA Mechanical Administrator Unlimited Com
Cours
ALASKA Mechanical Administrator Unlimited Com

Aperçu du contenu

ALASKA (AK) Mechanical Administrator Unlimited Commercial and Industrial
Plumbing Exam LATEST QUESTIONS AND CORRECT ANSWERS GRADE A



What is the minimum required size for the drain outlet for a commercial garbage disposal
unit with a 1-1/2 horsepower motor, according to the Uniform Plumbing Code (UPC)?

A) 1-1/2 inches

B) 2 inches

C) 3 inches

D) 4 inches

**Answer: B**

**Explanation:** UPC 802.2.1 requires a drain outlet of not less than 2 inches for
commercial food waste grinders with motors of 1 horsepower or greater.



When sizing the water heater for a commercial laundry facility, what is the primary factor
that must be determined first?

A) The floor area of the laundry room

B) The peak hourly demand in gallons of hot water at the required temperature

C) The voltage available at the service panel

D) The number of washing machines

**Answer: B**

**Explanation:** Sizing is based on the **peak hourly demand**, calculated using fixture
counts and demand factors from the UPC (or manufacturer specs for specific appliances),
not just the number of fixtures.



According to UPC requirements, what is the minimum slope for a 4-inch diameter
horizontal drain pipe installed inside a building?

A) 1/16 inch per foot

B) 1/8 inch per foot

, C) 1/4 inch per foot

D) 1/2 inch per foot

**Answer: B**

**Explanation:** UPC Table 704.1 specifies the minimum slope for a 4-inch diameter drain
pipe is **1/8 inch per foot (1%)**.



In a multi-story commercial building, what device must be installed to prevent excessive
static pressure on the lower floors in the domestic water supply system?

A) A check valve

B) A pressure-reducing valve (PRV)

C) An expansion tank

D) A vacuum breaker

**Answer: B**

**Explanation:** **Pressure-reducing valves (PRVs)** are required on individual floor
branches or zones where the static pressure from the height of the water column exceeds
80 psi (UPC 604.8) to prevent fixture damage and water hammer.



What is the minimum required number of water closets for a commercial office building
with 125 male employees and 125 female employees, according to the 2018 UPC?

A) 2 for men, 2 for women

B) 3 for men, 3 for women

C) 2 for men, 3 for women

D) 3 for men, 4 for women

**Answer: D**

**Explanation:** Using UPC Table 422.1: For 1-150 occupants, men require 1-3 water
closets (125 requires 3). Women require 1-4 water closets (125 requires 4). This is based on
the calculation for "Assembly" or "Office" occupancy.

École, étude et sujet

Établissement
ALASKA Mechanical Administrator Unlimited Com
Cours
ALASKA Mechanical Administrator Unlimited Com

Infos sur le Document

Publié le
18 janvier 2026
Nombre de pages
8
Écrit en
2025/2026
Type
Examen
Contenu
Questions et réponses

Sujets

12,84 €
Accéder à l'intégralité du document:

Mauvais document ? Échangez-le gratuitement Dans les 14 jours suivant votre achat et avant le téléchargement, vous pouvez choisir un autre document. Vous pouvez simplement dépenser le montant à nouveau.
Rédigé par des étudiants ayant réussi
Disponible immédiatement après paiement
Lire en ligne ou en PDF

Faites connaissance avec le vendeur
Seller avatar
GerryBlair

Faites connaissance avec le vendeur

Seller avatar
GerryBlair University Of Texas - Arlington
S'abonner Vous devez être connecté afin de pouvoir suivre les étudiants ou les formations
Vendu
1
Membre depuis
2 mois
Nombre de followers
0
Documents
60
Dernière vente
1 semaine de cela

0,0

0 revues

5
0
4
0
3
0
2
0
1
0

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions