CDC 3E151 - HVAC/R JOURNEYMAN VOLUME 3 EXAM QUESTIONS AND VERIFIED ANSWERS LATEST UPDATE 
 
(401) What relationship between magnetic field and conductors is required to generate voltage mechanically? 
Relative motion between the two 
(401) Nickel and chromium alloys are used in heater elements because they 
make it possible to operate the elements at high temperatures without melting 
(401) What effect does the length of a wire have on the amount of pressure needed to force the electrons to the ...
- Examen
- • 11 páginas's •
-
HVAC•HVAC
Vista previa 2 fuera de 11 páginas
Preparando tu documento...
CDC 3E151 - HVAC/R JOURNEYMAN VOLUME 3 EXAM QUESTIONS AND VERIFIED ANSWERS LATEST UPDATE 
 
(401) What relationship between magnetic field and conductors is required to generate voltage mechanically? 
Relative motion between the two 
(401) Nickel and chromium alloys are used in heater elements because they 
make it possible to operate the elements at high temperatures without melting 
(401) What effect does the length of a wire have on the amount of pressure needed to force the electrons to the ...
CDC 3E151 - HVAC/R JOURNEYMAN VOLUME 4 EXAM QUESTIONS WITH COMPLETE SOLUTIONS VERIFIED GRADED A+ 
 
 
(601) How is static electricity best controlled? 
Grounding, bonding, humidifying 
(601) Grounded wires carrying off static charges 
neutralizes the difference in electrical potential 
(601) A fuel spill should be reported when how many gallons or more is leaked or spilled? 
25 
(601) A leak of 35 gallons should be reported to the state regulator within 
24 hours 
(602) When the viscosity of an ...
- Examen
- • 8 páginas's •
-
HVAC•HVAC
Vista previa 2 fuera de 8 páginas
Preparando tu documento...
CDC 3E151 - HVAC/R JOURNEYMAN VOLUME 4 EXAM QUESTIONS WITH COMPLETE SOLUTIONS VERIFIED GRADED A+ 
 
 
(601) How is static electricity best controlled? 
Grounding, bonding, humidifying 
(601) Grounded wires carrying off static charges 
neutralizes the difference in electrical potential 
(601) A fuel spill should be reported when how many gallons or more is leaked or spilled? 
25 
(601) A leak of 35 gallons should be reported to the state regulator within 
24 hours 
(602) When the viscosity of an ...
HVAC KY598 JOURNEYMAN EXAM PREP QUESTIONS AND VERIFIED CORRECT ANSWERS GRADED A+ 
 
Soldering on a metal portion of a hydronic piping system shall be performed a minimum of ________ inches from any plastic to metal adapter in the same water line. 
18 
Where gas piping is required to be installed in conduit and one end terminates outdoors, the conduit must extend not less than ________ inches outside the building. 
4 
Domestic clothes dryer exhaust ducts shall be constructed of metal not less tha...
- Examen
- • 17 páginas's •
-
HVAC•HVAC
Vista previa 3 fuera de 17 páginas
Preparando tu documento...
HVAC KY598 JOURNEYMAN EXAM PREP QUESTIONS AND VERIFIED CORRECT ANSWERS GRADED A+ 
 
Soldering on a metal portion of a hydronic piping system shall be performed a minimum of ________ inches from any plastic to metal adapter in the same water line. 
18 
Where gas piping is required to be installed in conduit and one end terminates outdoors, the conduit must extend not less than ________ inches outside the building. 
4 
Domestic clothes dryer exhaust ducts shall be constructed of metal not less tha...
OK HVAC JOURNEYMAN TEST EXAM QUESTIONS AND ANSWERS WITH COMPLETE SOLUTIONS VERIFIED GRADED A+ 
 
 
C- leaky suction valve 
A deep vacuum is an evacuation method in which a technician uses a vacuum pump (or the systems compressor) to pull a vacuum until no moisture or other vapor remains in the system. If the compressor is used for this procedure, but CANNOT produce a deep vacuum, which of the following would be the problem? 
A- bad TXV 
B- low refrigerant 
C- leaky suction valve 
D- leaky exhaus...
- Examen
- • 53 páginas's •
-
HVAC•HVAC
Vista previa 4 fuera de 53 páginas
Preparando tu documento...
OK HVAC JOURNEYMAN TEST EXAM QUESTIONS AND ANSWERS WITH COMPLETE SOLUTIONS VERIFIED GRADED A+ 
 
 
C- leaky suction valve 
A deep vacuum is an evacuation method in which a technician uses a vacuum pump (or the systems compressor) to pull a vacuum until no moisture or other vapor remains in the system. If the compressor is used for this procedure, but CANNOT produce a deep vacuum, which of the following would be the problem? 
A- bad TXV 
B- low refrigerant 
C- leaky suction valve 
D- leaky exhaus...
OK HVAC JOURNEYMAN TEST EXAM QUESTIONS WITH COMPLETE SOLUTIONS VERIFIED GRADED A+ 
 
A deep vacuum is an evacuation method in which a technician uses a vacuum pump (or the systems compressor) to pull a vacuum until no moisture or other vapor remains in the system. If the compressor is used for this procedure, but CANNOT produce a deep vacuum, which of the following would be the problem? 
A- bad TXV 
B- low refrigerant 
C- leaky suction valve 
D- leaky exhaust valve 
C- leaky suction valve 
What ...
- Examen
- • 54 páginas's •
-
HVAC•HVAC
Vista previa 4 fuera de 54 páginas
Preparando tu documento...
OK HVAC JOURNEYMAN TEST EXAM QUESTIONS WITH COMPLETE SOLUTIONS VERIFIED GRADED A+ 
 
A deep vacuum is an evacuation method in which a technician uses a vacuum pump (or the systems compressor) to pull a vacuum until no moisture or other vapor remains in the system. If the compressor is used for this procedure, but CANNOT produce a deep vacuum, which of the following would be the problem? 
A- bad TXV 
B- low refrigerant 
C- leaky suction valve 
D- leaky exhaust valve 
C- leaky suction valve 
What ...
HVAC JOURNEYMAN PREP TEST EXAM QUESTIONS AND ANSWERS WITH COMPLETE SOLUTIONS VERIFIED LATEST UPDATE 
 
 
A listed smoke damper designed to resist the passage of smoke shall be provided at each point in a duct or air transfer opening penetrates a: (A)smoke barrier wall (B)fire rated wall (C)interior wall (D)corridor wall 
Corridor wall (IMC 607.5.4) 
Flexible air duct may be what length? (A)10' (B)2' (C)14' (D)6' 
14' (IMC 603.6.1.1) 
The maximum vertical distance between the front lower lip...
- Examen
- • 17 páginas's •
-
HVAC•HVAC
Vista previa 3 fuera de 17 páginas
Preparando tu documento...
HVAC JOURNEYMAN PREP TEST EXAM QUESTIONS AND ANSWERS WITH COMPLETE SOLUTIONS VERIFIED LATEST UPDATE 
 
 
A listed smoke damper designed to resist the passage of smoke shall be provided at each point in a duct or air transfer opening penetrates a: (A)smoke barrier wall (B)fire rated wall (C)interior wall (D)corridor wall 
Corridor wall (IMC 607.5.4) 
Flexible air duct may be what length? (A)10' (B)2' (C)14' (D)6' 
14' (IMC 603.6.1.1) 
The maximum vertical distance between the front lower lip...
HVAC JOURNEYMAN TEST EXAMS QUESTIONS WITH COMPLETE SOLUTIONS VERIFIED 2024 
Which type of air-conditioning system is most likely to leak refrigerant into a structure? A.direct B.indirect C.evaporative D.split. 
A.direct 
When mechanical equipment is located on a flat roof that is 8 foot above grade, how far from the roof edge must the equipment be located before a guard rail is not needed? A. Less than 6' B. 9' C. 4' D. More than 10' 
D. More than 10' 
A room that measures 10 x 20 x 8 conta...
- Examen
- • 6 páginas's •
-
HVAC•HVAC
Vista previa 2 fuera de 6 páginas
Preparando tu documento...
HVAC JOURNEYMAN TEST EXAMS QUESTIONS WITH COMPLETE SOLUTIONS VERIFIED 2024 
Which type of air-conditioning system is most likely to leak refrigerant into a structure? A.direct B.indirect C.evaporative D.split. 
A.direct 
When mechanical equipment is located on a flat roof that is 8 foot above grade, how far from the roof edge must the equipment be located before a guard rail is not needed? A. Less than 6' B. 9' C. 4' D. More than 10' 
D. More than 10' 
A room that measures 10 x 20 x 8 conta...
KY HVAC JOURNEYMAN EXAM QUESTIONS WITH COMPLETE VERIFIED SOLUTIONS GRADED A+ 
Liquid adhesive coatings used on air filters for air conditioning or heating systems shall have a flash point not lower than _______ : 
a: 200°F 
b: 250°F 
c: 350°F 
d: 325°F 
d: 325°F 
Refer: IMC Code 605.1 
Connectors shall connect to a chimney flue at a point not less than ______ above the lowest portion of the interior of the chimney flue: 
a: 10 inches 
b: 12 inches 
c: 16 inches 
d: 14 inches 
b: 12 inches 
...
- Examen
- • 29 páginas's •
-
HVAC•HVAC
Vista previa 3 fuera de 29 páginas
Preparando tu documento...
KY HVAC JOURNEYMAN EXAM QUESTIONS WITH COMPLETE VERIFIED SOLUTIONS GRADED A+ 
Liquid adhesive coatings used on air filters for air conditioning or heating systems shall have a flash point not lower than _______ : 
a: 200°F 
b: 250°F 
c: 350°F 
d: 325°F 
d: 325°F 
Refer: IMC Code 605.1 
Connectors shall connect to a chimney flue at a point not less than ______ above the lowest portion of the interior of the chimney flue: 
a: 10 inches 
b: 12 inches 
c: 16 inches 
d: 14 inches 
b: 12 inches 
...
HVAC JOURNEYMAN TEST EXAM QUESTIONS WITH COMPLETE SOLUTIONS VERIFIED 100% GUARANTEED PASS 
 
Sensible Heat 
Heat that can be Measured 
Specific Heat 
The Amount of Heat Required to Raise 1 LB of a Substance 1*F 
Latent Heat 
Heat used to cause change of state. 
BTU 
amount of heat required to raise 1LB of water 1*F 
One Ton of Refrigeration 
2000 x 144 x 24,288,000 Btu/24hours, and 12,000 Btu/hr 
A Room Thermostat Should be Mounted 
5 feet from the floor 
To Provide Proper Oil Return to the Comp...
- Examen
- • 2 páginas's •
-
HVAC•HVAC
Vista previa 1 fuera de 2 páginas
Preparando tu documento...
HVAC JOURNEYMAN TEST EXAM QUESTIONS WITH COMPLETE SOLUTIONS VERIFIED 100% GUARANTEED PASS 
 
Sensible Heat 
Heat that can be Measured 
Specific Heat 
The Amount of Heat Required to Raise 1 LB of a Substance 1*F 
Latent Heat 
Heat used to cause change of state. 
BTU 
amount of heat required to raise 1LB of water 1*F 
One Ton of Refrigeration 
2000 x 144 x 24,288,000 Btu/24hours, and 12,000 Btu/hr 
A Room Thermostat Should be Mounted 
5 feet from the floor 
To Provide Proper Oil Return to the Comp...
HVAC JOURNEYMAN TEST EXAM QUESTIONS WITH COMPLETE SOLUTIONS VERIFIED GRADED A+ 
 
Which type of air-conditioning system is most likely to leak refrigerant into a structure? A.direct B.indirect C.evaporative D.split. 
A.direct 
When mechanical equipment is located on a flat roof that is 8 foot above grade, how far from the roof edge must the equipment be located before a guard rail is not needed? A. Less than 6' B. 9' C. 4' D. More than 10' 
D. More than 10' 
A room that measures 10 x 20 x 8...
- Examen
- • 6 páginas's •
-
HVAC•HVAC
Vista previa 2 fuera de 6 páginas
Preparando tu documento...
HVAC JOURNEYMAN TEST EXAM QUESTIONS WITH COMPLETE SOLUTIONS VERIFIED GRADED A+ 
 
Which type of air-conditioning system is most likely to leak refrigerant into a structure? A.direct B.indirect C.evaporative D.split. 
A.direct 
When mechanical equipment is located on a flat roof that is 8 foot above grade, how far from the roof edge must the equipment be located before a guard rail is not needed? A. Less than 6' B. 9' C. 4' D. More than 10' 
D. More than 10' 