An _____ CASREP identifies the status of the casualty parts and
assistance requirements - ANSWERS-Initial
A _____ is submitted when changes to a previously filed CASREP are
required - ANSWERS-Update
A _____ is submitted when equipment identified on the CASREP is
repaired and back in operational status - ANSWERS-Correct
A _____ is submitted when equipment identified on teh CASREP is
scheduled to be repaired - ANSWERS-CASCAN
Utilizing MWT, boiler water is maintained within set parameters. These
parameters are _____ - ANSWERS--Alkalinity testing (pH) 8-11.5
-Total dissolved solids (TDS) below 1000 ppm
-Chloride less than 10 ppm
Vacuum/Gravity two-stage OWS has 3 indicator lights - ANSWERS-
Red Light-Control panel is on
Amber Light-Oil is being discharged from the system
Green Light-When water is being discharged from the system
END OF
PAGE
1
, MK1 SWE EXAM LATEST
This is done when 50% or more of the original text or when the
signature page is changed - ANSWERS-Revise
Cutter Engineering Report sections III, IV and V - ANSWERS-III-
Machiner/electrical
IV-Administrative
V-Cutter Engineering summary
CASREPS must include AIG 6842 or AIG 6843 as _____ addresses so
that CASREP data can be electronicallt entered into the Navy and Naval
Inventory Control Point (NAVICP) databases - ANSWERS-Info
To establish if there is an air leak in the OWS - ANSWERS-Perform
hydro static test on suction piping and vertical cylinder vessel
Permission to start BECCES shall be gained from - ANSWERS-CO or
OOD
Where would past training team evaluations be found? - ANSWERS-
The ships training record
END OF
PAGE
2
, MK1 SWE EXAM LATEST
Heat shall not exceed what temperature during drills - ANSWERS-100F
Units shall submit a CASREP as soon as possible, but not later than 24
hours after the occurrence of a significant casualty which cannot be
corrected within _____ - ANSWERS-48 hours
Casualty categories - ANSWERS-2-Minor degredation to primary or
major degradation/total loss of any secondary mission.
3-Major degradation but not loss of primary mission
4-Worse than 3, causes loss of at least 1 mission
Which manual publishes the complete list of CG directives and their
required distribution - ANSWERS-Directives, publications and reports
index
What chapter/section of the DPRI listing identifies the order from to use
to request updates, replacements or new directives - ANSWERS-Chapter
1, section C
END OF
PAGE
3
, MK1 SWE EXAM LATEST
What type of brush is used for cleaning the plates in a plate type heat
exchanger? - ANSWERS-Fiber brush
Which manual publishes the complete list of CG units and their
distribution symbols - ANSWERS-Standard distribution list
_____ is installed on the tank to prevent the pump motor and solenoid
valve from becoming energized in the event the condensate tank water
level is low. - ANSWERS-Float switch
On Auxiliary boilers, permanent magnets project a strong magnetic
field. The field acts as a stator and the feed pump provides the energy to
move the liquid _____ - ANSWERS-Armature
3 main types of hydraulic accumulators are spring and weight loaded
and _____ - ANSWERS-Gas charged
The internal engine overhaul documentation shall be maintained on
board the cutter until _____ - ANSWERS-
END OF
PAGE
4