TFM02 TEXAS FIRE EXTINGUISHER LICENSING TEST TYPE B EXAM QUESTIONS AND CORRECT DETAILED SOLUTIONS LATEST UPDATED VERSION JUST RELEASED

Institución
TFM02 TEXAS FIRE EXTINGUISHER LICENSING
Grado
TFM02 TEXAS FIRE EXTINGUISHER LICENSING











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
TFM02 TEXAS FIRE EXTINGUISHER LICENSING
Grado
TFM02 TEXAS FIRE EXTINGUISHER LICENSING

Información del documento

Subido en
7 de diciembre de 2025
Número de páginas
52
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Page 1 of 52




TFM02 TEXAS FIRE EXTINGUISHER LICENSING TEST
TYPE B EXAM QUESTIONS AND CORRECT DETAILED
SOLUTIONS LATEST UPDATED VERSION JUST
RELEASED

Question: 5 ft above the ground - ANSWER✔✔extinguishers weighing 40 lbs or less must be
installed so top of canister is no more than _____




Question: K - ANSWER✔✔class ___ extinguishers are for fires involving cooking media




Question: 75 ft - ANSWER✔✔OSHA specified max travel distance for Class A is ______




Question: C - ANSWER✔✔proper UL rating to use on electrically energized equipped




Question: Class K - ANSWER✔✔work on the principle of saponification




Question: Obstacle Type Fires - ANSWER✔✔involve flammable liquid on a horizontal surface
w/ the presence of a solid object creating a barrier

, Page 2 of 52


Question: 4 inches - ANSWER✔✔extinguishers must be installed at least _____ from the
ground




Question: Obstacle Type Fires - ANSWER✔✔may take place in flammable liquid storage
caninets, dip tank process areas, etc.




Question: Must Be Weighed - ANSWER✔✔To make sure the pressure gauges of CO2
extinguisher are showing adequate pressure, what must you do?




Question: 5 yrs - ANSWER✔✔Wetting agent portable extinguishers must be hydrostatic tested
every _____




Question: After recharge - ANSWER✔✔leak tests on stored pressure extinguishers must be
performed




Question: cannot - ANSWER✔✔how do u convert fire extinguishers from 1 type to another?




Question: any remaining dry chemical in a discharged extinguisher - ANSWER✔✔may be
reused only if checked for proper type, contamination, and condition. closed recovery system
needs to be used!

, Page 3 of 52


Question: New extinguishers needing charge in the field - ANSWER✔✔do not need to have any
verification of service collar installed




Question: you cannot - ANSWER✔✔how do u have an extinguisher converted to use a different
type of extinguishing agent




Q:A three dimensional fire often involves static flammable liquid. true or false -
ANSWER✔✔false. 3D firess unvolve flammable liquid in motion as well as both horizontal and
vertical surfaces.




Question: Class A fire extinguisher - ANSWER✔✔are ok for wood, paper, some plastics and
textiles. They offer the coating effects of dry chemicals.




Question: Dry chemical stored pressure fire extinguishers: - ANSWER✔✔should be removed or
replaced at their next 6 year maintenance or hydrostatic test interval.




Question: B:C - ANSWER✔✔Talking about UL rating, the _____ rating refers to the amount of
sq footage an extinguisher covers




Question: Class B fire extinguishers cannot handle flammable liquid - ANSWER✔✔False

, Page 4 of 52


Question: employees must be trained in proper use of all portable fire extinguishers according
to - ANSWER✔✔CRF29




Question: monthly - ANSWER✔✔you need to have portable fire extinguishers VISUALLY
inspected at least _____ according to 29 CFR 1910.157 (e) (2)




Question: Class A/B fire extinguishers - ANSWER✔✔should NOT be used forfire that involves
live electrical equipment




Question: annually - ANSWER✔✔Water or steam fire extinguishers need to be discharged,
dissassembled and inspected at least:




Question: 3.5 ft - ANSWER✔✔An extinguisher weighing over 40 lbs should be installed so the
top is no more than __ from the ground




Question: 50 ft. - ANSWER✔✔OSHA specified maximum travel distance to an extinguisher for
Class B




Question: 6 yrs - ANSWER✔✔dry chem extinguishers requiring 12 yr hydrostatic test must be
emptied for maintenance procedures every
$17.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Ressy JOHN HOPKINS
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
146
Miembro desde
2 año
Número de seguidores
31
Documentos
2548
Última venta
8 horas hace

3.5

30 reseñas

5
11
4
7
3
5
2
0
1
7

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes