Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 2 fuera de 11 páginas
Examen

EPA 608 (TYPE II) Exam Questions and Answers Graded A+

Document preview thumbnail
Vista previa 2 fuera de 11 páginas

EPA 608 (TYPE II) Exam Questions and Answers Graded A+

Vista previa del contenido

EPA 608 (TYPE II) Exam Questions and
Answers Graded A+

When a new system has been assembled, the first thing to do is? - Correct answer-

Pressurize the system with an inert gas & leak check.

After installation of a field-piped R-410A split heat pulp, the unit should first be? -

Correct answer-Pressurized with nitrogen then leak checked.

The EPA regulations require that any appliances containing more than 50 pounds

of refrigerant (except for commercial & industrial process refrigeration) must be

repaired when the leak rate exceeds _________ of the charge per year? - Correct

answer-15%

R-410A requires recovery tanks rated for at least? - Correct answer-400 psig

After refrigerant liquid has been recovered from a system, any remaining vapor is?

- Correct answer-Condensed by the recovery system.

Your recovery/recycling machine has R-502 refrigerant in it. You now have to

recover refrigerant from a unit with R-22. What must be done before the R-22



©COPYRIGHT 2025, ALL RIGHTS RESERVED 1

, refrigerant can be recovered/recycled? - Correct answer-Recover as much R-502

from the recovery unit as possible, change filter, & evacuate.

In a refrigeration system with a TXV (or other type of throttling device), the

component directly following the condenser is the? - Correct answer-Receiver

When charging an R-410A system that uses a water-cooled condenser, you must

first charge with vapor to a pressure of at least________, before switching to liquid

charging. - Correct answer-120 psig

Recovered refrigerant may contain what? - Correct answer-1.) Acids




2.) Moisture




3.) Oils

Your recovery/recycling machine has R-22 refrigerant in it. You now have to

recover refrigerant from a unit with R-410A. What must be done before your

recovery unit can be used to recover R-410A? - Correct answer-1.) The recovery

unit must be EPA certified for use with R-410A.




©COPYRIGHT 2025, ALL RIGHTS RESERVED 2

Información del documento

Subido en
2 de diciembre de 2025
Número de páginas
11
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$12.09

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
0
Seguidores
0
Artículos
963
Última venta
-


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes