Refrigeration Excellence Exam Questions and Answers Graded A+

Puntuación
-
Vendido
-
Páginas
40
Grado
A+
Subido en
02-12-2025
Escrito en
2025/2026

Refrigeration Excellence Exam Questions and Answers Graded A+

Institución
AHA CPR
Grado
AHA CPR











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
AHA CPR
Grado
AHA CPR

Información del documento

Subido en
2 de diciembre de 2025
Número de páginas
40
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Refrigeration Excellence Exam Questions
and Answers Graded A+

1. In a dry type (direct expansion) evaporator, liquid refrigerant must boil away as

close to the end of the coil as possible in order to:

A. Operate at high-efficiency

B. Ensure that Frost is not accumulate

C. Subcool the compressor

D. Ensure proper oil return - Correct answer-A. Operate at high-efficiency

2. The difference between the temperature of the refrigerant boiling in the

evaporator and the temperature at the evaporator outlet is known as

A. Evaporator superheat

B. Latent heat

C. Evaporator sub-cooling

D. Sublimation - Correct answer-A. Evaporator superheat

3. An expansion device that is stuck open will cause
©COPYRIGHT 2025, ALL RIGHTS RESERVED 1

,A. Low suction pressure

B. A starved evaporator

C. Excessive superheat

D. A flooded evaporator - Correct answer-D. A flooded evaporator

4. When measuring evaporator superheat on a commercial system that has a long

suction line, the pressure reading should be taken at the

A. Compressor inlet

B. Evaporator outlet

C. Condenser outlet

D. Receiver Inlet - Correct answer-A. Compressor inlet

5. Superheat measurements are best taken

A. During a hot pulldown

B. At 8°F two 12°F

C. During defrost

D. With the system operating at design conditions - Correct answer-D. With the

system operating at design conditions



©COPYRIGHT 2025, ALL RIGHTS RESERVED 2

,6. A technician is checking the superheat on a multi circuit evaporator and finds

one of the circuits has a superheat that is higher than the others. This could be

caused by

A. A dirty coil

B. A refrigerant overcharge

C. Uneven air distribution

D. A blocked distributor - Correct answer-D. A blocked distributor

7. A TXV with an external equalizer is used on

A. Evaporators with a high pressure drop

B. Evaporators with a low pressure drop

C. High temperature application is only

D. All evaporators - Correct answer-A. Evaporators with a high pressure drop

8. Dry type evaporators operate most efficiently with the superheat setting of

approximately

A. 8°F to 12°F

B. 13°F to 19°F

C. 20°F to 30°F
©COPYRIGHT 2025, ALL RIGHTS RESERVED 3

, D. 31°F to 40°F - Correct answer-A. 8°F to 12°F

9. An evaporator used to chill liquids is operating within normal superheat setting.

But the system is not cooling the product properly. Which of the following is most

likely the cause?

A. Overcharge of refrigerant

B. Undercharge of refrigerant

C. The circulator

D. The TXV - Correct answer-A. Overcharge of refrigerant

10. What time interval is required between each superheat adjustment?

A. Not less than one hour

B. About 10 to 15 minutes

C. At least a half hour

D. No time delay - Correct answer-B. About 10 to 15 minutes

11. A low temperature evaporator used for cooling space or product refrigeration

A. Is the same as one used for medium or high temperatures

B. Must have fins space closer together



©COPYRIGHT 2025, ALL RIGHTS RESERVED 4
$12.79
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
EmmaGrants

Conoce al vendedor

Seller avatar
EmmaGrants Howard Community College
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
Nuevo en Stuvia
Miembro desde
4 semanas
Número de seguidores
0
Documentos
964
Última venta
-
Howard Community College Study Hub.

Welcome to HCC Study Hub, your go-to place for top-quality study materials from Howard Community College. Whether you're prepping for exams or just consolidating your notes, you'll find: -Lecture notes from past courses -Practice exams with detailed answers -Comprehensive study guides -Package deals for full semester bundles All documents are carefully reviewed, accurate, and designed to help you succeed. Uploads are updated regularly based on the latest course syllabi. Happy studying — and good luck!

Lee mas Leer menos
0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes