Lighting system covered by Article 411 shall have a power supply rated
not more than ——amps and not more than 30V. - ANSWERS-25 amps


The demand factor for marina load calculations of 45 shore power
receptacles is ____%. - ANSWERS-50%


Which flexible cable is allowed to be used for a Electric Vehicle
Charging Station? - ANSWERS-EVJ


Communication circuits shall have a minimum grounding conductors of
____AWG. - ANSWERS-#12 AWG


Lighting system operating at 30V or less shall not be installed within
____ feet of pools, spas, fountains, or similar locations. - ANSWERS-
10'ft


The working space in front of the electric equipment shall not be less
than ____ inches wide, or the width of the equipment, whichever is
greater. - ANSWERS-30" inches


END OF
PAGE
1

, NYC MASTER LATEST
ELECTRICIAN EXAM
(ELECTRICAL EXAM)
The minimum clearance for overhead feeder conductors not exceeding
600V that pass over commercial areas subject to truck traffic is ____
feet. - ANSWERS-18" feet


A limited care facility is an area used on a ____hour basis for the
housing of four or more persons who are incapable of self-preservation
because of age, physical limitation due to accident or illness, or mental
limitations, mental illness, or chemical dependency. - ANSWERS-24hr


For equipment rated 1200A or more and over 6ft wide that contains
over-current devices, switching devices, or control devices, there shall
be one entrance to and egress from the required working space not less
than 24inches. Wide and ____ nches high at each end of the working
space. - ANSWERS-6'foot 6"inches (78" inches)


Rigid metal conduit that is directly buried outdoors shall have at least
____inches of cover. - ANSWERS-6" inches


Type ____ is multiconductor cable identified for use as underground
service entrance cable. - ANSWERS-Type USE cable

END OF
PAGE
2

, NYC MASTER LATEST
ELECTRICIAN EXAM
(ELECTRICAL EXAM)

Knife switch rated for more than 1200 Amps at 250Volts or less -
ANSWERS-Can be used only as isolating switch, shall not be opened
under load


Track lighting with outlets in a bathroom is not allowed because ? -
ANSWERS-Track lighting has receptacle


Where internal combustion engines are used as the prime motor, an on
site fuel supply shall be provided with an on premise fuel supply
sufficient for not less than ____ hours full demand operation of the
system - ANSWERS-6 hours


Fixed in place X-ray equipment properly supplied by a branch circuit
rated at not over ____ amperes shall be permitted to be supplied through
a suitable attachment plug cap and hard service cable cord. -
ANSWERS-30 Amps


Where skin effect exist the ferromagnetic envelope shall be bonded at
____. - ANSWERS-Both ends

END OF
PAGE
3

, NYC MASTER LATEST
ELECTRICIAN EXAM
(ELECTRICAL EXAM)

GFCI protection at a carnival is not required for equipment at circuit if
the receptacle is of the ____type. - ANSWERS-Locking


The maximum voltage drop from service point to the last over-current
device in a dwelling unit? - ANSWERS-4%


Which of the following statements best describe the grounding
requirement for central vacuum outlet - ANSWERS-Accessible non
current carrying metal parts are required to be connected to an
equipment grounding conductor.


In healthcare facilities, patient bed receptacles located in general care
areas shall be supplied by at least two branch circuits, which
____permitted to originate from two separate transfer switches on the
emergency system - ANSWERS-Are permitted


Patient care areas of healthcare facilities ____ areas such as business
offices, corridors, lounges ,day rooms, or similar areas - ANSWERS-Do
not include

END OF
PAGE
4

Información del documento

Subido en
21 de noviembre de 2025
Número de páginas
48
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$18.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Teacher101
4.6
(276)
Vendido
506
Seguidores
74
Artículos
11179
Última venta
7 horas hace


Reseñas de compradores verificados



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes