100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

ASSE 6005 Certification Questions with Answers Verified 100% Correct

Puntuación
-
Vendido
-
Páginas
5
Grado
A+
Subido en
19-11-2025
Escrito en
2025/2026

ASSE 6005 Certification Questions with Answers Verified 100% Correct Source Valve - ANSWER -Shutoff valve at immediate connection of each source to piped distribution system Cryogenic Fluid - ANSWER -A fluid with a boiling point lower than -130 deg F at an absolute pressure of 14.7 psi Main Line Valve - ANSWER -Shutoff valve in main supply line inside of the building 200 psi - ANSWER -Instrument air design pressure Riser Valve - ANSWER -Shutoff valve in each riser adjacent to main line Service Valve - ANSWER -Shutoff valve in each lateral branch from main or riser Zone Valve - ANSWER -Shutoff valves for station outlets and inlets In-line Valve - ANSWER -Shutoff valves for servicing individual rooms or areas Diameter Index Safety System - ANSWER -D.I.S.S. Pin Index - ANSWER -Medaes/Ohmeda/Ohio Latch Type - ANSWER -Chemetron Geometric Type - ANSWER -Puritan Bennett Quick Connect - ANSWER -Schrader Primary Valve - ANSWER -Allows user to disconnect equipment without causing leakage Secondary Valve - ANSWER -Allows for removal of front assembly for maintenance and repair without leakage by automatically closing to stop flow of gas 24 hours - ANSWER -Standing pressure test length National Institute of Standards and Technology - ANSWER -NIST 23.5% - ANSWER -Oxygen concentration by volume for an oxygen enriched atmosphere CGA E-10 - ANSWER -CGA Standard to establish a maintenance program at a facility 72 in^2 - ANSWER -Minimum free area for louvered openings for natural ventilation Demand Check Fitting - ANSWER -Used to facilitate service, testing, or replacement of all pressure switches and mainline gauges downstream of the source valve 21 CFR 210 and 21 CFR 211 - ANSWER -FDA Current Good Manufacturing Practices for bulk liquid oxygen 20 ft - ANSWER -Height above ground for medical air intakes 36 in - ANSWER -Minimum backfilled cover for buried piping 18 in - ANSWER -Minimum backfilled cover for buried piping where physical damage is otherwise prevented ASME Section IX - ANSWER -Brazing procedures and brazer performance shall be qualified in accordance with ______ 1000 - ANSWER -Melting temperature for brazing alloys BCuP series - ANSWER -Filler metal for copper-to-copper joints 80 psi - ANSWER -Pressure where outlets need to be either D.I.S.S. Or designed to relief pressure before removal of adapter 20 ft - ANSWER -Maximal interval for pipe labels 1000 psi - ANSWER -Minimum burst pressure for flex hose and connectors ASTM B88, ASTM B819, ASTM B280, Stainless Steel - ANSWER -Pipe types for medical-surgical vacuum systems Oxygen Analyzer - ANSWER -Used to assure all ambient air has been removed from the pipeline prior to brazing Specific Name - ANSWER -Indicated on continuous tape or marker to identify buried pipeline 150 psi - ANSWER -Minimum test pressure for initial pressure test Schedule 40 - ANSWER -Minimum wall thickness for Category 3 vacuum system with plastic piping ASTM B819 - ANSWER -Hard-drawn, seamless copper tube for Category 3 positive pressure gases Brass, Bronze, Stainless Steel - ANSWER -Allowable pressure relief valve materials

Mostrar más Leer menos
Institución
ASSE 6005 Certification
Grado
ASSE 6005 Certification









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
ASSE 6005 Certification
Grado
ASSE 6005 Certification

Información del documento

Subido en
19 de noviembre de 2025
Número de páginas
5
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

ASSE 6005 Certification Questions with Answers
Verified 100% Correct
Source Valve - ANSWER -Shutoff valve at immediate connection of each source
to piped distribution system

Cryogenic Fluid - ANSWER -A fluid with a boiling point lower than -130 deg F
at an absolute pressure of 14.7 psi

Main Line Valve - ANSWER -Shutoff valve in main supply line inside of the
building

200 psi - ANSWER -Instrument air design pressure

Riser Valve - ANSWER -Shutoff valve in each riser adjacent to main line

Service Valve - ANSWER -Shutoff valve in each lateral branch from main or
riser

Zone Valve - ANSWER -Shutoff valves for station outlets and inlets

In-line Valve - ANSWER -Shutoff valves for servicing individual rooms or areas

Diameter Index Safety System - ANSWER -D.I.S.S.

Pin Index - ANSWER -Medaes/Ohmeda/Ohio

Latch Type - ANSWER -Chemetron

Geometric Type - ANSWER -Puritan Bennett

Quick Connect - ANSWER -Schrader

, Primary Valve - ANSWER -Allows user to disconnect equipment without causing
leakage

Secondary Valve - ANSWER -Allows for removal of front assembly for
maintenance and repair without leakage by automatically closing to stop flow of
gas

24 hours - ANSWER -Standing pressure test length

National Institute of Standards and Technology - ANSWER -NIST

23.5% - ANSWER -Oxygen concentration by volume for an oxygen enriched
atmosphere

CGA E-10 - ANSWER -CGA Standard to establish a maintenance program at a
facility

72 in^2 - ANSWER -Minimum free area for louvered openings for natural
ventilation

Demand Check Fitting - ANSWER -Used to facilitate service, testing, or
replacement of all pressure switches and mainline gauges downstream of the
source valve

21 CFR 210 and 21 CFR 211 - ANSWER -FDA Current Good Manufacturing
Practices for bulk liquid oxygen

20 ft - ANSWER -Height above ground for medical air intakes

36 in - ANSWER -Minimum backfilled cover for buried piping

18 in - ANSWER -Minimum backfilled cover for buried piping where physical
damage is otherwise prevented
$10.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TheExamMaestro Teachme2-tutor
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
121
Miembro desde
1 año
Número de seguidores
5
Documentos
3167
Última venta
1 semana hace
Exam Vault

Exam Vault is your trusted destination for high-quality exam materials and study resources. We provide a wide rage of tests and prep guides to help you succeed, whether you're preparing for academic exams, certifications, or professional assessments

3.8

13 reseñas

5
7
4
2
3
1
2
0
1
3

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes