Hydro elevators in low rise applications do not need an _____
_____ room. Ans: — overhead machine
Some advantages of hydros are lower equipment and building
construction costs because the load of a hydro is carried to the
_____ where as the load of a traction car is carried by the _____
_____. Ans: — ground, building structure
When drilling the jack hole, the only proper way to determine if
the hole is plumb is to remove the drill stem and bit and use a
_____ _____. Ans: — Spider Bob
To plumb the hole, a spider bob is attached to a length of piano
wire suspended from as near as possible to the top of the _____ or
from a fixed point on the drill rig. Ans: — Hoistway
When welding a joint, lay _____ inch tack welds _____ degrees
apart, shift it 90 degrees and lay two more 1 inch tack welds 180
degrees apart. Ans: — 1, 180
On power units having the motor beneath the tank, the pump may
be either _____ driven or _____ coupled. Ans: — belt, direct
The purpose of the _____/_____ is to silence the effect of any
pulsations in the pump output and should be as close to the pump
as possible. Ans: — silencer, muffler
On Bolsters/Bolster Assembly, the plunger is fastened to the _____
_____ which is then mounted to the center of the Bolster Assembly.
Ans: — platen plate
With wye-delta, reduced current starting is accomplished without
the need for _____. Ans: — resistors
© 2025 All rights reserved
, 2 | Page
_____ run buttons should run the platform and sling at leveling
speeds only. Ans: — Temporary
A _____ _____ consists of a piston held closed by an adjustable
spring and must open at a certain pressure to prevent any further
increase in pressure. Ans: — relief valve
A _____ lowering valve allows the car to be lowered at a speed not
exceeding 20fpm in case of power failure. Ans: — manual
As the oil temperature changes, the _____ will change as well and
will effect the performance, more specifically, the leveling and
approach of the elevator. Ans: — viscosity
Be sure wellways are properly _____ to avoid accidental injury to
you, your team or anyone working outside of our industry. Ans: —
barricaded
Barricades around the wellway must be _____ inches high and be
capable of withstanding a _____lb force. Ans: — 42, 200
A _____ protects you if you come in contact with a hot wire or
component and then come in contact with ground. It opens the
circuit and diverts the supplied current to ground. Ans: — GFCI
A _____ _____ is useful for horizontal (side-to-side) pulling of the
truss while being lowered into the wellway. Ans: — lever hoist
Code specifies the use of anti-slide devices if the outer edge of the
deck is greater than _____ inches from the center line of the
handrail. Ans: — 12
(True/False) Anti-slide devices must be less than 3/4" in height,
have no sharp corners or edges and fastened to the deck no closer
than 4 inches from the handrail and spaced no greater than 6ft
apart. Ans: — True
Sometimes referred to as sag switches, _____ _____ switches are
located within the step band of both upper and lower truss