100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

NACE CIP Level 1 Practical Exam Questions & Answers Solved 100% Correct!!

Puntuación
-
Vendido
-
Páginas
2
Grado
A+
Subido en
14-11-2025
Escrito en
2025/2026

High Voltage Holiday Detector Pannel - CORRECT ANSWER--When determining the Voltage used, if not shown on dial use Voltage immediately below what's needed -Remember the selection must be either High or Low and the corresponding number next to the Voltage. SSPC-PA2 - CORRECT ANSWER-Dry Film Thickness Gauge SSPC-PA2 Type 1 - CORRECT ANSWER-Magnetic Pull-Off DFT Gauge -Dial-Type Magnetic Pull-Off DFT Gauge (Banana Gauge) -Pencil Type Magnetic Pull-Off DFT Gauge Dial TypeMagnetic Pull-Off DFT Gauge - CORRECT ANSWER--Known as "Banana Gauge" -Intrinsically Safe -Some Models Can Be Used Underwater ASTM D 7091 - CORRECT ANSWER--Calibration: Gauge Shall be Calibrated by manufacturer or third party lab. -BMR: In order to compensate for any effects from the blast profile must calculate the Base Metal Reading. -Verify Accuracy: Use certified metal plates and Gauge must be within 5% of expected range. NACE SP0188 - CORRECT ANSWER-High and Low Voltage Holiday Testing Low-Voltage Holiday Detector - CORRECT ANSWER--Ground is attached directly to substrate. -Sponge saturated with a solution of tap water/wetting agent -Proper mix ratio 1oz/USgal -Proper of speed is 1ft/sec Double Stroke -Used on Coatings up to 20mils -may be used on concrete Low Voltage Holiday Detectors Common Errors - CORRECT ANSWER--Failure to Keep probe in contact with surface -Moving the electrode too fast or slow -Over or under saturating the sponge -Low battery or bad lead/ground connection Telegraphing - CORRECT ANSWER-Can occur when surface is saturated with water and the Detector reads a different area.High Voltage Holiday Detectors - CORRECT ANSWER--Can have an Output range from 800-60,000v -In General Voltage ratio 100v/1mil -Electrode Rate of 1ft/sec with a single pass -Ground connection must be made direct to metal substrate(preferred) or indirectly for pipeline in soil. Type 1 DFT Gauge Adjustment - CORRECT ANSWER--Take 10 reading on the blasted steel surface and average the results. -Take DFT measurements - Subtract BMR from DFT Averages

Mostrar más Leer menos
Institución
NACE CIP Level 1 Practical
Grado
NACE CIP Level 1 Practical








Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
NACE CIP Level 1 Practical
Grado
NACE CIP Level 1 Practical

Información del documento

Subido en
14 de noviembre de 2025
Número de páginas
2
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

NACE CIP Level 1 Practical Exam
High Voltage Holiday Detector Pannel - CORRECT ANSWER--When determining the
Voltage used, if not shown on dial use Voltage immediately below what's needed
-Remember the selection must be either High or Low and the corresponding number
next to the Voltage.

SSPC-PA2 - CORRECT ANSWER-Dry Film Thickness Gauge

SSPC-PA2 Type 1 - CORRECT ANSWER-Magnetic Pull-Off DFT Gauge
-Dial-Type Magnetic Pull-Off DFT Gauge (Banana Gauge)
-Pencil Type Magnetic Pull-Off DFT Gauge

Dial TypeMagnetic Pull-Off DFT Gauge - CORRECT ANSWER--Known as "Banana
Gauge"
-Intrinsically Safe
-Some Models Can Be Used Underwater

ASTM D 7091 - CORRECT ANSWER--Calibration: Gauge Shall be Calibrated by
manufacturer or third party lab.
-BMR: In order to compensate for any effects from the blast profile must calculate the
Base Metal Reading.
-Verify Accuracy: Use certified metal plates and Gauge must be within 5% of expected
range.

NACE SP0188 - CORRECT ANSWER-High and Low Voltage Holiday Testing

Low-Voltage Holiday Detector - CORRECT ANSWER--Ground is attached directly to
substrate.
-Sponge saturated with a solution of tap water/wetting agent
-Proper mix ratio 1oz/USgal
-Proper of speed is 1ft/sec Double Stroke
-Used on Coatings up to 20mils
-may be used on concrete

Low Voltage Holiday Detectors Common Errors - CORRECT ANSWER--Failure to Keep
probe in contact with surface
-Moving the electrode too fast or slow
-Over or under saturating the sponge
-Low battery or bad lead/ground connection

Telegraphing - CORRECT ANSWER-Can occur when surface is saturated with water
and the Detector reads a different area.
$7.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
ACADEMICMATERIALS City University New York
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
562
Miembro desde
2 año
Número de seguidores
186
Documentos
10590
Última venta
3 días hace

4.1

95 reseñas

5
53
4
11
3
21
2
3
1
7

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes