QUESTIONS AND ANSWERS
Clean Agent. ANSWER -Electrically non-conducting, volatile, or gaseous fire
extinguishant that does not leave a residue upon evaporation.


High-Pressure Cylinder. ANSWER -containing nitrogen, compressed air, carbon dioxide,
or other gases at a pressure higher than 500 psi (3447 kPa) at 70°F (21°C).


Low-Pressure Cylinder. ANSWER -containing fire- extinguishing agent (medium),
nitrogen, compressed air, or other compressed gases at a service pressure of 500 psi (3447
kPa) or lower at 70°F (21°C).


Dry Powder. ANSWER -Solid materials in powder or granular form designed to extinguish
CLASS D combustible metal fires by crusting, smothering, or heat-transferring means.


Flammable Liquids of Appreciable Depth are those with a depth greater than. ANSWER -
1/4 in

, What are halogenated agents. ANSWER -clean agents


acceptable halons?. ANSWER -1211, 1301


Each fire extinguisher shall be marked with the following:. ANSWER -(1) Identification of
the listing and labeling organization
(2) Product category indicating the type of extinguisher
(3) Extinguisher classification as indicated in Section 5.3
(4) Performance and fire test standards that the extinguisher meets or exceeds


Class D extinguishing agents hall comply with:. ANSWER -ANSI/UL 711,


CAN/ULC-S508.


ExtinguisherslistedfortheClassC rating shall not contain an agent that is a. ANSWER -
conductor of electricity


Obsolete extinguishers. ANSWER -(1) Soda acid
(2) Chemical foam (excluding film-forming agents)
(3) Vaporizing liquid (e.g., carbon tetrachloride)
(4) Cartridge-operated water
(5) Cartridge-operated loaded stream
(6) Copper or brass shell (excluding pump tanks) joined by
soft solder or rivets
(7) Carbon dioxide extinguishers with metal horns


Dry chemical stored-pressure extinguishers manufac- tured prior to October _________
shall be removed from service at the next 6-year maintenance interval or the next hydrotest,
whichever comes first.. ANSWER -1984


Class A Fires. ANSWER -Class A fires are fires in ordinary combustible materials, such as
wood, cloth, paper, rubber, and many plastics.

Información del documento

Subido en
13 de noviembre de 2025
Número de páginas
15
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$13.39

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
8
Seguidores
0
Artículos
1088
Última venta
1 mes hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes