100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

NEC Challenge Exam 3 Questions With Correct Answers

Puntuación
-
Vendido
-
Páginas
7
Grado
A+
Subido en
13-11-2025
Escrito en
2025/2026

NEC Challenge Exam 3 Questions With Correct Answers

Institución
NEC
Grado
NEC









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
NEC
Grado
NEC

Información del documento

Subido en
13 de noviembre de 2025
Número de páginas
7
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

NEC Challenge Exam 3 Questions With
Correct Answers

1. |Barriers |shall |be |placed |in |all |service |panelboards, |switchboards, |and |switchgear |such |that |
no |uninsulated, |ungrounded |service |_____ |or |service |terminal |is |exposed |to |inadvertent |
contact |by |persons |or |maintenance |equipment |while |servicing |load |terminations. |- |CORRECT |
ANSWER✔✔-408.3(A)(2) |busbar



2. |Where |equipment |grounding |is |required |for |an |installation |of |HDPE, |a |separate |equipment |
grounding |conductor |shall |be |_____. |- |CORRECT |ANSWER✔✔-353.6 |installed |within |the |
conduit



3. |Floor-mounted |flat |conductor |cable |and |fittings |shall |be |covered |with |carpet |squares |no |
larger |than |______. |- |CORRECT |ANSWER✔✔-324.41 |39.37 |in. |square



4. |Cable |bus |framework |that |is |_____ |shall |be |permitted |was |the |equipment |grounding |
conductor |for |branch |circuits |and |feeders. |- |CORRECT |ANSWER✔✔-370.60(1) |bonded



5. |The |metallic |sheath |of |metal-clad |cable |shall |be |continuous |and |________. |- |CORRECT |
ANSWER✔✔-330.116 |close |fitting



6. |The |voltage |drop |on |technical |power |systems |for |sensitive |electronic |equipment |shall |not |
exceed |_______ |percent |for |branch |circuits. |- |CORRECT |ANSWER✔✔-647.4(D) |1.5



7. |A |recessed |luminaire |not |identified |for |contact |with |insulation |shall |have |all |recessed |parts |
spaced |not |less |than |_____ |in. |from |combustible |materials, |except |for |points |of |support. |- |
CORRECT |ANSWER✔✔-410.166(A)(1) |1/2

, 8. |Receptacles |or |their |cover |plates, |supplied |from |the |life |safety |or |equipment |branches |in |
nursing |homes |shall |have |a |distinctive |color |or |marking |so |as |to |be |readily |identifiable. |- |
CORRECT |ANSWER✔✔-517.42(E) |TRUE



9. |a |nonmetallic |surface |raceway |is |a |nonmetallic |raceway |that |is |intended |to |be |mounted |to |
the |surface |of |a |structure, |with |associated |couplings, |connectors, |boxes, |and |fittings |for |the |
installation |of |electrical |conductors. |- |CORRECT |ANSWER✔✔-388.2 |Surface |Nonmetallic |
Raceway |TRUE



10. |An |insulated |grounded |conductor |_____ |AWG |or |smaller |shall |be |identified |by |a |
continuous |white |or |gray |outer |finish, |or |by |three |continuous |white |or |gray |outer |finish, |or |by |
three |continuous |white |or |gray |stripes |along |its |entire |length |on |other |than |green |insulation. |-
|CORRECT |ANSWER✔✔-200.6(A)(1), |(2), |and |(3) |6




11. |Where |single-conductor |Type |MI |cables |are |used |, |all |phase |conductors |and, |when |used, |
the |______ |conductor, |shall |be |grouped |together |to |minimize |induced |voltage |on |the |sheath. |-
|CORRECT |ANSWER✔✔-332.31 |neutral




12. |Where |ventilation |marking |is |not |required, |the |electric |vehicle |supply |equipment |shall |be |
clearly |field |marked, |that |"ventilation |is |not |required." |- |CORRECT |ANSWER✔✔-625.15(B) |
FALSE



13. |The |connection |between |the |grounded |circuit |conductor |and |the |supply-side |bonding |
jumper |or |equipment |grounding |conductor, |or |both, |at |a |_____ |is |called |a |"system |bonding |
jumper." |- |CORRECT |ANSWER✔✔-100 |Bonding |Jumper, |System |separately |derived |system



14. |Article |647 |covers |the |installation |and |wiring |of |separately |derived |systems |that |operate |at
|_____ |volts-to-ground |and |______ |volts |line-to-line |for |sensitive |electronic |equipment. |- |


CORRECT |ANSWER✔✔-647.1 |60, |120
$14.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Lectphilip West Virginia University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
177
Miembro desde
1 año
Número de seguidores
6
Documentos
19137
Última venta
2 horas hace
WELCOME TO LECTPHILIP, A PLACE WHERE WE UNLOCK YOUR ACADEMIC OPPORTUNITIES

On this page, you find all documents, package deals and flashcards offered by seller lectphilip

4.1

28 reseñas

5
14
4
6
3
5
2
2
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes