100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

Backflow Assembly Tester Cert. Workshop Exam 2026 Questions and Answers

Puntuación
-
Vendido
-
Páginas
46
Grado
A+
Subido en
10-11-2025
Escrito en
2025/2026

Backflow Assembly Tester Cert. Workshop Exam 2026 Questions and Answers

Institución
Virginia Commercial Pesticide Applicators CORE
Grado
Virginia Commercial Pesticide Applicators CORE











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Virginia Commercial Pesticide Applicators CORE
Grado
Virginia Commercial Pesticide Applicators CORE

Información del documento

Subido en
10 de noviembre de 2025
Número de páginas
46
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Backflow Assembly Tester Cert.
Workshop Exam 2026 Questions and
Answers

1. Backflow is the undesirable reversal of flow of water or other substances

through a cross

connection into the public water system or consumer's:

a. non potable water system.

b. used water system or consumer's potable water system.

c. public water system or consumer's potable water system.

d. public water system or consumer's non potable system. - Correct answer-c.

public water system or consumer's potable water system.

2. An approved air gap (AG) is a physical separation between the free-flowing

end of a:

a. non potable water supply pipeline and the overflow rim of an open or


©COPYRIGHT 2025, ALL RIGHTS RESERVED 1

,non-pressurized

receiving vessel.

b. potable water supply pipeline and the overflow drain of an open or

non-pressurized receiving

vessel.

c. potable water supply pipeline and the overflow rim of an open or

pressurized receiving

vessel.

d. potable water supply pipeline and the overflow rim of an open or

non-pressurized receiving

vessel. - Correct answer-d. potable water supply pipeline and the overflow rim of

an open or

non-pressurized receiving

vessel.

3. An indirect cross-connection is one that is subject to what type of backflow?

a. only backsiphonage


©COPYRIGHT 2025, ALL RIGHTS RESERVED 2

,b. only backpressure

c. only low hazard, backsiphonage or backpressure

d. high or low hazard, backsiphonage or backpressure - Correct answer-a. only

backsiphonage

4. Cross-connections between the potable water piping and any piping or

containers

containing substances not approved as potable water must be either

eliminated or

controlled by the installation of an:

a. air gap or a backflow prevention device.

b. approved air break or an backflow prevention device.

c. approved air gap or an approved backflow prevention device.

d. approved air gap or an approved backflow prevention assembly. - Correct

answer-d. approved air gap or an approved backflow prevention assembly.

5. While testing CV#2 of a DCVA, if CV #2 leaks, the BAT would observe that the

water flow:



©COPYRIGHT 2025, ALL RIGHTS RESERVED 3

, a. stops from the sight tube at TC #3 and no differential shows on the gauge.

b. stops from the sight tube at TC #4 and at least 1.0 psid shows on the gauge.

c. continues from the sight tube at TC #4 and at least 1.0 psid shows on gauge

d. stops from the sight tube at TC #4 and no differential shows on the gauge. -

Correct answer-d. stops from the sight tube at TC #4 and no differential shows on

the gauge.

6. Service protection is a way to protect a public water system from contamination

due to backflow from the customer's water system by the installing an approved

backflow preventer at the:

a. service connection which is considered to be at or near the water meter.

b. service connection which is considered to be the end of the customer's potable

water system furthest from the meter

c. point of use which is considered to be the start of the customer's potable

water system where the pipe goes through the outside wall of the building.

d. point of use which is normally considered to be inside the building. - Correct

answer-a. service connection which is considered to be at or near the water meter.

7. A Washington state certified Backflow Assembly Tester is certified to:


©COPYRIGHT 2025, ALL RIGHTS RESERVED 4
$13.29
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
EmillyCharlotte Howard Community College
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
98
Miembro desde
1 año
Número de seguidores
5
Documentos
12005
Última venta
3 semanas hace
ALL-MAJOR.

On this page, you find all documents, package deals, and flashcards offered by seller Emilly Charlotte.

3.5

21 reseñas

5
7
4
6
3
2
2
3
1
3

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes