CORRECT Answers
What must you have signed by a. Form 13671 (Consumer consent form from owner or agent)
the customer before entering
into a contact on a property that
3 multiple choice options
is currently under an active
WDO warranty?
The eastern subterranean b. Rhinotermitidae 3 multiple choice options
termite belongs to the family ___?
Drywood and dampwood a. Kalotermitidae 3 multiple choice options
termites belong to the family ___?
According to the revised c. Blattodae 3 multiple choice options
taxonomy of termites, these
insects belong in the order ___
along with cockroaches?
The old house borer is an d. Longhornedwood-borer 3 multiple choice options
example of a ___?
Which is required to be c. Evidence, Damage, and Live Organisms 3 multiple choice options
reported on the Form 13645
Inspection report?
When must you use the Form d. Both a and b 3 multiple choice options
13645 Inspection Report?
Which is the minimum amount of a. Not less than $500,000 in the aggregate and $250,000 per
Errors and Omissions Liability occurence
Insurance required for a licensee
to conduct Form 13645, WDO 3 multiple choice options
inspections?
Which are two documents that b. The Industry Baseline practices and the Guidelines for the use
can give you guidance on and completion of the 13645 form
completing a Form 13645
3 multiple choice options
Inspection Report?
, Under the definitions as they a. Powderpost beetle frass streaming out of holes
pertain to WDO inspections,
Live or Living would include all 3 multiple choice options
of the following EXCEPT ___?
Under the definitions as they d. Detached privacy fences 3 multiple choice options
pertain to WDO inspections,
structure would include all of
the following but not ___ ?
Which of these items could be b. Stored items and debris stacked against the structure
stated as areas on to exclude an
exterior area of a structure from
3 multiple choice options
the Form 13645 Inspection
Report?
Which of the following is NOT d. Wood roof shingles 3 multiple choice options
an example of a conductive
condition that may lead to the
presence of wood-destroying
organisms?
Which would not be a valid b. Insulation covers truss tails 3 multiple choice options
reason for excluding the
inspection of the entire attic of a
structure?
Conductive conditions for b. Oak trees located on the property 3 multiple choice options
termite or wood-decaying fungi
infestations would include all of
the following but not?
If you do not properly check a. The area was inspected and considered accessible
any boxes in section 3
(obstructions and inaccessible
3 multiple choice options
areas) on Form 13645, then you
have indicated that?
As part of Form 13645; c. Ambrosia beetle stains 3 multiple choice options
inspection, evidence of a wood-
destroying organism would NOT
include?
The purpose of Form 13645 d. none of the above 3 multiple choice options
inspection report is to
communicate information about
the presence or absence of
wood-destroying organisms at
the time of the inspection,
therefore, it is considered to be
warrantied for?
According to the industry b. 20 inches x 20 inches 3 multiple choice options
baseline practices. what is the
minimum opening size for an
attic entrance?
According to industry baseline a. 22 x 48 3 multiple choice options
practices, what is the minimum
opening size through the truss
webbing in the attic?