100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

CT REGISTRY- (excluding anatomy) Exam Correctly Solved Questions And Answers {100% Correct} 2025|2026

Puntuación
-
Vendido
-
Páginas
57
Grado
A+
Subido en
08-11-2025
Escrito en
2025/2026

CT REGISTRY- (excluding anatomy) Exam Correctly Solved Questions And Answers {100% Correct} 2025|2026

Institución
CT REGISTRY
Grado
CT REGISTRY











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
CT REGISTRY
Grado
CT REGISTRY

Información del documento

Subido en
8 de noviembre de 2025
Número de páginas
57
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

CT REGISTRY- (excluding anatomy)
Exam Correctly Solved Questions And
Answers {100% Correct} 2025|2026
how do you reduce beam hardening CORRECT ANSWERS 1. Increase dose
2. Reduce collimation--Reduce slice thickness
3. Increase window width

At what level does the abdominal aortal bifurcate? CORRECT ANSWERS L4

What is the typical scan delay after injection of contrast media for studies of the liver?
CORRECT ANSWERS 30-45 seconds

What window settings provide the best tissue differentiation within the liver? CORRECT
ANSWERS window width= 140, level= 60

What is the window settings that provide the best bone window for the pelvis?
CORRECT ANSWERS window width=2000, window level=350

What mAs is typically used in routine CT exams of the abdomen? CORRECT
ANSWERS 200-300 mAs

What is the result of the bifurcation of the abdominal aorta? CORRECT ANSWERS The
right and left common iliac arteries

What is the anode target angle? CORRECT ANSWERS 12 degrees

At what level do the common carotids bifurcate into the internal and external carotid
arteries? CORRECT ANSWERS C3-C4

The floor of the orbit is formed by the __________ bones. CORRECT ANSWERS
maxillary and zygomatic

The lateral wall of the orbit is formed by the ___________ bones. CORRECT
ANSWERS zygomatic and sphenoid

The medial wall of the orbit is formed by the _________ bones. CORRECT ANSWERS
ethmoid and lacrimal bones

how do you calculate effective mAs? CORRECT ANSWERS mAs/pitch

define window level and window width CORRECT ANSWERS LEVEL: a chosen
midpoint in the grayscale

,WIDTH: number of grayscale values above and below the level.
- The width is DIVIDED in HALF and distributed above and below the level.
- Anything above the window is white
- Anything below the window is black

The wider the window the more grayscale values, the lower the contrast!

example:
Level 100, Width 300
White = >+250
Black = <-50

Level 100, Width 200
White = >+200
Black = <0

Level 100, Width 150
White = >+175
Black = <25

factors that affect spatial and contrast resolution CORRECT ANSWERS Spatial
resolution:
1) focal spot
2) detector width (aperture)
3) reconstruction algorithm - bone>soft tissue
4) slice thickness - thinner is better
5) pixel/FOV/matrix
6) pitch - decreased pitch means no gaps
7) nyquist limitations

Contrast resolution: CNR
1) energy of X-rays - kVp - ↑ kVp ↓ contrast
2) number of X-rays - mA - ↑ mA ↓ mottle
3) slice thickness - thicker is better
4) reconstruction method - iterative > filtered
5) reconstruction algorthith - soft tissue>bone

Give window levels for brain, lung, abdomen, bone CORRECT ANSWERS Brain:
W80,L+40
Lung: W1500, L-400
Abdomen: W400, L+50
Bone: W1600, L+500

What is beam hardening?
what are the two types of beam hardening artifact?

,how do you compensate for it? CORRECT ANSWERS 1) as the X-ray beam passes
through an object, lower energy photons are removed (like filtration!) leaving a "harder
beam" of high energy photons. This causes two artifacts:

2) Cupping: the center of a round object is darker than the periphery due to hardening of
the beam 360 degrees around the object. happens in the head

3) Streak: these are dark bands that occur in between two dense objects - nearly all the
photons are removed in a line between the two objects

4) fixes:
A) Filtration: pre-hardening the beam to remove low energy photons
B) Calibration: using a phantom to set a compensated mA/kVp
C) Correct software: iterative reconstruction may help
D) Avoidance: tilting the gantry of positioning the patient to avoid areas that may cause
hardening.

ring artifact CORRECT ANSWERS Calibration error or defective detector cause
consistently erroneous reading at each angular position, resulting in a circular artifact

is the focal spot large or small? CORRECT ANSWERS large 0.6-1.2 - so as not to
overheat the anode from such a high mA

Which of the following will result in an increased voxel size: B increased slice thickness
CORRECT ANSWERS A)decreased reconstruction FOV B) increased slice thickness
C) increased matrix D) none of these

If a tissue with a CT number of +300 appears white on the image, which of the following
are the window width and window level selected: A)window level =0, window width =500
B)window level= +300, window width= 500 C)window level =+100, window width =1000
D)none of these CORRECT ANSWERS A) window level =0, window width =500

What is the volume of a voxel if a slice thickness of 3 mm, a 512x512 matrix & a
reconstruction field of view of 25.6cm are used A) 0.75mm³ B)1.5mm³ C) 6.0mm³
D)none of these CORRECT ANSWERS A. Solve this by finding the pixel size first
FOV/matrix size ... that is 0.5 ... now square that 0.25 .... multiply that by slice thickness
and you get 0.75

Which of the following parameters is responsible for partial volume averaging: A) matrix
size B) kVp C)slice thickness D) patient dose CORRECT ANSWERS C

Voxel equation CORRECT ANSWERS pixel area x section thickness

What is interpolation? CORRECT ANSWERS Mathematical method for taking SPIRAL
data and viewing it as AXIAL images

, Bone windows CORRECT ANSWERS 2000-4000 WW
200-400 WL

Lung windows CORRECT ANSWERS 1400-1600 WW
(-)400-600 WL

Modular Transfer Function? CORRECT ANSWERS graphical representation of
SPATIAL RESOLUTION measured in lp/cm, tells how small you can scan without
blurring

Decrease partial volume averaging? CORRECT ANSWERS Reduce slice thickness

Which portion of the pancreas is the most common site for tumors?; and where located?
CORRECT ANSWERS The head of the pancreas. It is located approximately at T12

LUNG WINDOW
(-) IS AIR CORRECT ANSWERS 2000 WW and -200 WL =

The Hounsfield unit that is -1000 most likely represents which of the following?
CORRECT ANSWERS Air

Relative to CT topography, slice thickness is best represented by which of the following
axes? CORRECT ANSWERS Z axis

What unit is the basis for exposure based on ionization in air? CORRECT ANSWERS
mR or C/kg

What radiation unit considers the biological effectiveness of radiation exposure?
CORRECT ANSWERS mrem or mSv

"Fan" beam technology first historically came on the scene with which acquisition
geometries? CORRECT ANSWERS Second

"Rotate-rotate" applies to which of the following geometries? CORRECT ANSWERS
Third

In CT what imaging plane is the pituitary best visualized? CORRECT ANSWERS
coronal

The third ventricle of the brain communicates with the fourth ventricle through the
CORRECT ANSWERS Cerebral aqueduct

refers to an excessive Amount of nitrogenous materials in the blood and is a symptom
of renal failure. CORRECT ANSWERS Azotemia
$24.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
ElevatedExcellence Exam
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
897
Miembro desde
3 año
Número de seguidores
504
Documentos
18038
Última venta
2 días hace
GETSOCIO EDUCATION

We have launched our assignments at a very reasonable price so that every student can enjoy its features. Our new method is gathering quite a positive feedback from the students, and many of our alumnus are fully satisfied with it. We would be glad if you purchase from us. THANK YOU!!

3.8

171 reseñas

5
77
4
36
3
27
2
10
1
21

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes