100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

APPRENTICE LINEMAN YEAR 3 EXAM 2025/2026 QUESTIONS AND ANSWERS 100% PASS

Puntuación
-
Vendido
-
Páginas
22
Grado
A+
Subido en
07-11-2025
Escrito en
2025/2026

APPRENTICE LINEMAN YEAR 3 EXAM 2025/2026 QUESTIONS AND ANSWERS 100% PASS

Institución
APPRENTICE LINEMAN
Grado
APPRENTICE LINEMAN










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
APPRENTICE LINEMAN
Grado
APPRENTICE LINEMAN

Información del documento

Subido en
7 de noviembre de 2025
Número de páginas
22
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

APPRENTICE LINEMAN YEAR 3 EXAM
2025/2026 QUESTIONS AND ANSWERS
100% PASS




Select the three common types of URD Systems - ANS Double Feed, Radial Feed, and Loop
Feed


True or False: A URD system is usually connected to the overhead primary distribution lines at a
cable or riser pole. - ANS True


True or False: Customers using three-phase equipment on a URD system must be powered by a
set of three-phase conductors separate from the rest of the URD. - ANS False


True or False: A loop feed system can be converted into an open loop system by opening any
switching point of the system. - ANS True


True or False: An open loop system is the same as two radial feed systems that have the
capability to be joined. - ANS True



A _____________ protects a URD system from over-voltages. - ANS Surge Arrestor




1 @COPYRIGHT 2025/2026

,A pad-mounted switch that connects a URD system to an underground feeder cable is called a -
ANS Transclosure



Select the types of equipment often found on cable poles. - ANS Surge protectors, pothead,
disconnect switches, and fuses.


True or False: Dead-front transformers are fully insulated and can be switched by a lineman
using rubber gloves. - ANS False



Select the three types of transformer installations in URD systems. - ANS Direct-buried, pad-
mounted, subsurface.



True or False: Tap holes are used to energize and de-energize transformers - ANS False



True or False: URD cable is often made of softer alloys then overhead cable. - ANS True


One a large customer of three-phase power is associated with a URD system, the system may
be fed directly from a ___________ through an underground feeder. - ANS Substation



What are the functions of a pothead? - ANS Terminate the URD cable insulation, Provide the
connection between overhead cable and URD cable


True or False: URD cable can be installed in the same trench with other types of cable and
utilities. - ANS True


When a URD cable must go under a building, a parking lot, or a street, it is often installed in
_________ to make replacing the cable easier. - ANS Conduit




2 @COPYRIGHT 2025/2026

, Before opening a pad-mounted transformer, a Lineman should perform a __________ to make
sure all equipment appears safe. - ANS Visual Inspection


True or False: during a transformer inspection, a lineman uses a system diagram to tag all
unmarked cables. - ANS False


True or False: at a pad-mounted switch, a lineman checks the position of each switch against
the system diagram and returns each switch to the correct position. - ANS False



__________ allow several different cables to be connected at one point. - ANS Terminal
Strips


Which of the following can be a valuable source of information during troubleshooting? -
ANS The troubleman's experience, customers and eyewitnesses, and a dispatcher


True or False: if only one customer loses power, while other surrounding customers have
normal service, troubleshooting should begin by checking the main feeder. - ANS False



Which of the following is NOT a method of locating a problem? - ANS Documenting



True or False: troubleshooting ends as soon as a problem is located. - ANS False


True or False: patrolling is scheduled only when specific problems have been reported on a line.
- ANS False


A Troubleman should always treat lines and equipment as if they are _____________. -
ANS Energized




3 @COPYRIGHT 2025/2026
$12.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TheStar Florida State University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
611
Miembro desde
2 año
Número de seguidores
179
Documentos
24416
Última venta
3 días hace
Stuvia Prodigy

Tested, Verified and Updated Study Materials with 100% Guaranteed Success.

3.8

122 reseñas

5
58
4
22
3
21
2
4
1
17

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes