Steve Med Gas Test Study Guide Exam
with Verified solution
Authority Having Jurisdiction (AHJ) - CORRECT
ANSWERS ✔✔An existing system that is not in strict
compliance with the provisions of this code shall be
permitted to be continued in use as long as the _____has
determined that such use does not constitute a distinct
hazard to life.
Designated Storage Area - CORRECT ANSWERS
✔✔Indoor locations for oxygen, nitrous oxide, and
mixtures of these gases shall not communicate with any
of the following EXCEPT
Visual Pressure Indicator - CORRECT ANSWERS ✔✔An
auxiliary source connection shall consist of all of the
following EXCEPT
Each Building Served - CORRECT ANSWERS ✔✔When
multiple buildings are served from a single cryogenic
liquid oxygen source, it is required to place the
emergency oxygen supply connection in...__________
3Ft - CORRECT ANSWERS ✔✔The minimum
clearance around the EOSC for a temporary source of
supply is ____ft.
,Steve Med Gas Test Study Guide Exam
with Verified solution
Be filtered to .01 microns - CORRECT ANSWERS
✔✔The quality medical air shall comply with all of the
following standards EXCEPT
Human Respiratory Applications - CORRECT ANSWERS
✔✔Medical air sources shall only be used for ____
1 micron or greater - CORRECT ANSWERS ✔✔Medical
air filters shall be sized for 100% of the system peak
calculated demand and be rated for a minimum of 98%
efficiency at _____micron or greater.
At least duplexed - CORRECT ANSWERS ✔✔In a
medical air supply system dryers, filters, and regulators
shall be_________.
25 feet - CORRECT ANSWERS ✔✔The medical air
intake shall be located a minimum of ___ft from all
exhausts or other noxious fumes.
20 Ft. - CORRECT ANSWERS ✔✔The medical air
intake shall be located outdoors a minimum of ___ft above
ground level.
, Steve Med Gas Test Study Guide Exam
with Verified solution
10 ft. - CORRECT ANSWERS ✔✔The medical air
intake shall be minimum of ___Ft from all doors, windows,
or other openings in a building.
30 in. of HgV - CORRECT ANSWERS ✔✔Vacuum
receivers shall be capable of withstanding a guage
vacuum of ____in. of HgV
Any method to ensure continual service - CORRECT
ANSWERS ✔✔A medical-surgical vacuum receiver
shall be made serviceable by ___.
Any non-corroding - CORRECT ANSWERS ✔✔A
medical-surgical vacuum exhaust shall be turned down
and screened. The screening shall be fabricated using
_________material.
grooved joint - CORRECT ANSWERS ✔✔Vacuum
exhaust from multiple pumps joined together to one
common exhaust shall be permitted provided each pump
can be isolated. The pumps can be isolated by all of the
following except a _______________.
psychiatric or pediatric - CORRECT ANSWERS
✔✔With the approval of the authority having jurisdiction,
with Verified solution
Authority Having Jurisdiction (AHJ) - CORRECT
ANSWERS ✔✔An existing system that is not in strict
compliance with the provisions of this code shall be
permitted to be continued in use as long as the _____has
determined that such use does not constitute a distinct
hazard to life.
Designated Storage Area - CORRECT ANSWERS
✔✔Indoor locations for oxygen, nitrous oxide, and
mixtures of these gases shall not communicate with any
of the following EXCEPT
Visual Pressure Indicator - CORRECT ANSWERS ✔✔An
auxiliary source connection shall consist of all of the
following EXCEPT
Each Building Served - CORRECT ANSWERS ✔✔When
multiple buildings are served from a single cryogenic
liquid oxygen source, it is required to place the
emergency oxygen supply connection in...__________
3Ft - CORRECT ANSWERS ✔✔The minimum
clearance around the EOSC for a temporary source of
supply is ____ft.
,Steve Med Gas Test Study Guide Exam
with Verified solution
Be filtered to .01 microns - CORRECT ANSWERS
✔✔The quality medical air shall comply with all of the
following standards EXCEPT
Human Respiratory Applications - CORRECT ANSWERS
✔✔Medical air sources shall only be used for ____
1 micron or greater - CORRECT ANSWERS ✔✔Medical
air filters shall be sized for 100% of the system peak
calculated demand and be rated for a minimum of 98%
efficiency at _____micron or greater.
At least duplexed - CORRECT ANSWERS ✔✔In a
medical air supply system dryers, filters, and regulators
shall be_________.
25 feet - CORRECT ANSWERS ✔✔The medical air
intake shall be located a minimum of ___ft from all
exhausts or other noxious fumes.
20 Ft. - CORRECT ANSWERS ✔✔The medical air
intake shall be located outdoors a minimum of ___ft above
ground level.
, Steve Med Gas Test Study Guide Exam
with Verified solution
10 ft. - CORRECT ANSWERS ✔✔The medical air
intake shall be minimum of ___Ft from all doors, windows,
or other openings in a building.
30 in. of HgV - CORRECT ANSWERS ✔✔Vacuum
receivers shall be capable of withstanding a guage
vacuum of ____in. of HgV
Any method to ensure continual service - CORRECT
ANSWERS ✔✔A medical-surgical vacuum receiver
shall be made serviceable by ___.
Any non-corroding - CORRECT ANSWERS ✔✔A
medical-surgical vacuum exhaust shall be turned down
and screened. The screening shall be fabricated using
_________material.
grooved joint - CORRECT ANSWERS ✔✔Vacuum
exhaust from multiple pumps joined together to one
common exhaust shall be permitted provided each pump
can be isolated. The pumps can be isolated by all of the
following except a _______________.
psychiatric or pediatric - CORRECT ANSWERS
✔✔With the approval of the authority having jurisdiction,