100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

Massachusetts Oil Burner License Exam 2025 – Complete Study Guide, Practice Test, and DFS Licensing Requirements

Puntuación
-
Vendido
-
Páginas
26
Grado
A+
Subido en
03-11-2025
Escrito en
2025/2026

Massachusetts Oil Burner License Exam 2025 – Complete Study Guide, Practice Test, and DFS Licensing Requirements

Institución
Massachusetts Oil Burner License
Grado
Massachusetts oil burner license










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Massachusetts oil burner license
Grado
Massachusetts oil burner license

Información del documento

Subido en
3 de noviembre de 2025
Número de páginas
26
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

1|Page


Massachusetts Oil Burner License Exam 2025 – Complete Study
Guide, Practice Test, and DFS Licensing Requirements




Prepare for the Massachusetts Oil Burner License Exam 2025 with this official study guide
and practice test. Learn about Massachusetts fire codes, fuel oil regulations, burner installation
standards, and safety procedures to pass the DFS exam and become a licensed oil burner
technician.




Massachusetts oil burner license exam 2025
Massachusetts oil burner technician license
MA oil burner license requirements
Massachusetts fire services oil burner exam



What is a low limit used for on a steam boiler or hot water boiler - ANSWER-It maintains the water temp
in the boiler



How are primary controls wired - ANSWER-L Black L2 white Terminal 3 goes to the burner motor
Terminal 4 goes to interrupted ignition all must be flexible



What is a reverse acting aquastat used for on a hot water boiler - ANSWER-Normal open switch that
close on temperature rise to operate circulators



What two problems will a vacuum test reveal - ANSWER-1 an air leak 2 restriction in the pipe



What causes a whining sound in a pump - ANSWER-High vacuum pressure. (it must be air bound, too
much air in the line.) line needs to be bled out.



What should the smoke test before a properly tuned Appliance - ANSWER-Zero two a Trace

,2|Page




What is a sword - ANSWER-A clean device that is a three to four foot long with a handle it also has a saw
blade looking thing on the other end is used in tight spaces or brushes can't reach



What is the purpose of a reverse acting control - ANSWER-To prevent cold water from being circulated
on cold start



Explain how a burner should be piped when the supply tank is located below the burner - ANSWER-2.
Pipe dual stage with a bypass plug



How should a stack switch be installed according to 527 CMR 4.00 - ANSWER-With a flexible conduit



Why should a stack switch not be rigidly mounted - ANSWER-So you can pull it out and check it



What are the purposes of a hot and cold contacts in stack switches - ANSWER-Hot: as they heat up hot
contacts close .Cold: normally closed switches open when heat heats them up.



What is delayed ignition - ANSWER-Fuel introduced to the combustion chamber before ignition



What are two causes of delayed ignition - ANSWER-The igniter electrodes or weak Transformer



how is a cad cell primary control relay put in step - ANSWER-The reset button



On domestic oil tanks when is it necessary to install a vent alarm - ANSWER-On tanks greater than 10
gallons



Must every fuel tank have a gauge - ANSWER-No .only on tanks greater than 10 gallons.



What is the Pensky Martens test - ANSWER-It's a Flashpoint test

, 3|Page


List all requirements for the fill and vent pipes - ANSWER-Swing joints on the fill pipe minimum of one
and one-quarter inch and the vent has to be as large or larger than the fill. vent must be two feet away
from any opening in the house and it must be three feet off grade



List all the devices necessary for safe operation of a forced hot water system with domestic start from
the fuse box - ANSWER-Fuse box emergency switch thermal cut-out service which limit switch primary
control




How is a safety lockout determined on a stack switch without removing it from its holder - ANSWER-
Remove the third terminal



Is CO2 test determines - ANSWER-The percentage of carbon dioxide in the flue gas



When Shall steam heating boiler and a hot water boiler require inspection by the commissioner of mass
Dept of Public Safety before it is put into service - ANSWER-Any time a permit is pulled to install or alter
a burner



Where is the check valve installed on a two pipe system when there is a lift situation - ANSWER-As close
to the tank as possible supply-side



How many seconds must have primary safety control shut off the burner - ANSWER-Firing Less Than 3
gallons per hour 45 seconds firing 3 - 7 gallons per hour 15 seconds



What is normal pump pressure - ANSWER-100 PSI



What would be the advantages of a pump pressure higher than 100 PSI - ANSWER-A cleaner burn



What determines the size of a nozzle gallons per hour - ANSWER-The maximum firing rate



What is the purpose of a draft regulator - ANSWER-To get the proper amount of air flow through the
burner
$22.89
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
lectmorgann

Documento también disponible en un lote

Conoce al vendedor

Seller avatar
lectmorgann Chamberlian School of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
0
Miembro desde
4 meses
Número de seguidores
0
Documentos
145
Última venta
-

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes