To prevent freezing of downstream equipment in a coil handling a large amount of outdoor air,
which of the

following is required?



a) A long coil length



b) A vacuum breaker



c) A preheat coil



d) An oversized coil



e) Two-position damper motor - correct answer ✔✔ c



It is good practice to select steam coils which require at

least 40% of coil capacity when air temperature is 1 degree C for which of the following
reasons?



a) Steam flow is high enough at high temperature and

prevents build-up and freezing of condensate

,b) The load on the circulating fan is kept from overheating



c) The mixing valve will never cut out if capacity stays

above 40%



d) To avoid hot condensate splashing



e) None of the above - correct answer ✔✔ a



Steam coils with a short tube length of 1.1 m or less



a) are more likely to freeze, even if the steam trap is

properly chosen



b) are not recommended because they are more likely to freeze



c) are more likely to freeze, even if the coil is properly

piped and sloped



d) are less likely to freeze if the steam trap is properly

chosen and the coil is properly piped



e) are less likely to freeze regardless of steam trap choice and coil piping - correct answer ✔✔ d



Steam coils with long tube lengths

, a) have the greatest freezing problems at extremely low

temperatures such as -35 degrees C



b) have the greatest freezing problems at temperatures of

about -2 to -1 degrees C



c) have freezing problems at any temperature



d) are not likely to freeze at any temperature



e) are less likely to freeze than steam coils with short

tube lengths - correct answer ✔✔ b



Freezing problems in steam coils with long tube lengths,

handling a large amount of low temperature outside air



a) are minimized by using preheat coils controlled by an

outdoor temperature controller



b) are minimized by using modulating control valves to

control the steam heating coil output



c) are best minimized by using a two-position control valve

to control coil output



d) are minimized by using an oversized coil

Información del documento

Subido en
1 de noviembre de 2025
Número de páginas
16
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$22.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
BravelRadon
3.5
(163)
Vendido
949
Seguidores
540
Artículos
52145
Última venta
1 semana hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes