A chimney top should be at least _____ above the roof and _____ higher than anything within _____ feet. A. 10..... 3..... 2 B. 2..... 10..... 3 C. 3..... 2..... 10 D. 3..... 10..... 2 3..... 2..... 10 OSB Siding is a. Fiber Cement b. A type of plywood. c. A type of waferboard. d. A type of hardboard. C. A type of wafer board

Mostrar más Leer menos
Institución
Home Inspection
Grado
Home inspection










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Home inspection
Grado
Home inspection

Información del documento

Subido en
24 de octubre de 2025
Número de páginas
19
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

National Home Inspector Exam Prep
questions and answers
Which of the following defects can result in a serious safety problem in the bathroom
✔✔Water damage on the floor around the toilet that's what

Which of the following elements is not a common characteristics of a railing system?
✔✔Balcony

What is delaminating and where is it likely to occur ✔✔It is the deterioration of wood
trim or wood surfaces on windows and doors.Noncontact moisture meter ✔✔if water is
filtration is suspected behind a finish surface. What would be the best choice to verify
dampness

Gas, fire, furnaces, heat exchanges most often fail from ✔✔Rust and fatigue

Relative humidity is expressed as ✔✔percentage

Connections of dissimilar metal in a plumbing system, such as galvanized steel pipe
and copper pipe, will usually cause ✔✔Electrolysis

An undergrounded receptacle may be replaced by a ground, fault circuit interrupter
installed ✔✔Upstream from the receptacle

Circuit breakers ✔✔protect the wire from an electrical overload

In a force air heating system, containing a split system air condition and
humidifier,humidity is reduced by ✔✔Condensation of the evaporator coil

Waterhammer can occur as a result of ✔✔A lack of air chambers

If a system designed for use with natural gas is supplied with propane gas ✔✔The
flame will be too high, unless a smaller orifice is installed

When looking at the exterior wall of a 60 year old brick masonry house with a gable
roof, you notice a horizontal crack in the mortar and outward brick displacement along
the gutter edge of the roof. The displacement is greatest at the center of the top 3
courses of brick This condition is MOST likely caused by. ✔✔Improper ceiling joist
installation

,You inspect a wood framed cantilevered balcony off of a 2nd story bedroom you find a
significant wood deterioration, of all cantilever Joists at the bearing point of the house
you should ✔✔Notify the occupants of the significant hazard advise immediate repair to
both the occupant and the client in the report

When a cooling unit is located in an attic where damage may result from condensate
overflow ✔✔An auxiliary condensate drain system is required

If poured concrete foundation has an unusually large amount of vertical cracks, each,
no wider than 1/32 inch cause likely to be ✔✔Shrinkage of the concrete from access
water at the time of pouring

Where should squash blocks web blocking, be found in the wood joist floor system
✔✔At bearing ends and low bearing walls above, with support girders below

Columns typically support ✔✔Girders

In new construction the minimum overhead electrical service clearances are
✔✔walkway: 10 feet, roadway: 18 feet, deck: 10 feet

During a summertime inspection, we could indicate chronic condensation problems in a
attic ✔✔There are no vapor retarder on the insulation

Ice damming at the eaves may be caused by ✔✔In adequate attic insulation

The purpose of flashing on a roof is to ✔✔Shed water onto roofing materials

While inspecting a heat pump is the cooling mode you measure a 28°F temperature
differential between the interior supply and return air you should suspect: ✔✔A dirty
filter

What is the minimum electric service drop clearance from a residential driveway? ✔✔12
feet

Roof truss uplift can cause cracks to form ✔✔At interior wall/ceiling intersections

When measuring the temperature drop across the evaporator in a central air
conditioning system a properly running unit on a humid summer day should read
between ✔✔15 and 25 degrees Fahrenheit

Knob and tube wiring may be acceptable if ✔✔Not covered by Installation

The maximum acceptable variation in a riser height within a flight of stairs is ✔✔3/8 inch

, While conducting an inspection, your ladder falls over and breaks the homeowners
priceless vase. What type of insurance is needed to cover the replacement?
✔✔General liability

The minimum reliable, separation between a masonry chimney and combustible
materials ✔✔2 inches

Bonding of appliances can be confirmed by using in ✔✔Ohm meter

Service panel enclosure doors is required to open at least ✔✔90°

What is a required element of a contract? ✔✔consideration

Buckling in a horizontal vinyl siding is generally caused by? ✔✔Improper fastening

At what level would water pressure with a single-family dwelling began to be considered
excessive in require correction ✔✔80 psi

A new home with electric heating is being inspected. It has a below grade finish
basement containing a bedroom the inspector should look for a smoke alarm, and.
✔✔An escape and rescue opening

A swimming pool fence must prevent passage of a sphere that is larger than ✔✔4
inches

A ground fault circuit interrupter is a safety device that ✔✔Disconnects the power when
sensing current leakage to the ground

An electric system, with a fuse on the neutral conductor, and on the energized (hot)
conductors ✔✔Is hazardous and should be corrected

To operate a central air condition, electric clothes dryer, and electric range the
amperage of the service to the house should be at least. ✔✔100 amps at 240 volts

brick chimneys on older properties with oil heat sometimes curve above the roofline with
no visible cracks. Which is the possible cause of curving? ✔✔Expansion of motar

Low pressure boiling pipes. Do not carry steam pressure above. ✔✔15 Psi

Roof Truss ✔✔Are usually designed for two point bearing

On a hillside house with foundation drain systems, ✔✔The foundation drain system
collect water, passing laterally through the slope
$14.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
Gnurse

Conoce al vendedor

Seller avatar
Gnurse NEWCASTLE UNIVERSITY
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
0
Miembro desde
1 año
Número de seguidores
0
Documentos
213
Última venta
-

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes