What class is a style D initiating device circuit? Class A A placard must be installed within ___ ft of the main fire alarm system controls. 3 ft When installing Class A circuits, the outgoing and return conductors are never allowed to be run in the same raceway, or enclosure. False Where circuit conductors enter a standard single-gang device box, the minimum length a free conductor measured from the face of the box or plastering shall not be less than____. 6 inches

Mostrar más Leer menos
Institución
FLSD
Grado
FLSD









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
FLSD
Grado
FLSD

Información del documento

Subido en
23 de octubre de 2025
Número de páginas
8
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Fire Life Safety questions and
answers
What class is a style D initiating device circuit? ✔✔Class A

A placard must be installed within ___ ft of the main fire alarm system controls. ✔✔3 ft

When installing Class A circuits, the outgoing and return conductors are never allowed
to be run in the same raceway, or enclosure. ✔✔False

Where circuit conductors enter a standard single-gang device box, the minimum length
a free conductor measured from the face of the box or plastering shall not be less
than____. ✔✔6 inches

Alarm notification appliances must be tested? ✔✔annually

The National Fire Protection Association (NFPA) code that covers the application,
performance, and maintenance of fire alarm systems and their components is
_________. ✔✔NFPA 72Manual fire alarm boxes shall be located within _______of the
exit doorway. ✔✔5 feet

A ceiling shall be treated as a smooth ceiling if the beams project no more than ______
below the ceiling. ✔✔4 inches

The maximum travel distance to the nearest manual fire alarm box shall not exceed
________, measured horizontally on the same floor. ✔✔200 feet

After batteries have discharged one full cycle, how many hours do you to recharge?
✔✔48 hours

What date do batteries have to have on a booster panel? ✔✔Month/year/manufacturer

Wall mounted telephone appliance or related fireman's phone jack shall be mounted no
higher than? ✔✔66 inches

Activation time of alarm notification appliances shall be within how many seconds after
activation of an initiating device? ✔✔10 seconds

Additional manual fire boxes shall be so the travel distance to the nearest fire box will
not be farther than? ✔✔200 feet

, What can be determined by observing the direction of current flow through a circuit?
✔✔Voltage polarity

If a ceiling is smooth, all points on the ceiling shall have a detector located within how
many times the selected spacing? ✔✔0.7 times

Radiant energy detectors shall be categorized as spark/ember and _____ ? ✔✔flame
detectors

Visible notification appliances shall be located not more than ____ from the end of a
corridor. ✔✔15 feet

The total sound pressure level produced by combining the ambient sound pressure
level with all audible notification appliances operating shall not exceed what dBa at the
minimum hearing distance? ✔✔110 dBa

If a defect or malfunctioning is not corrected at the conclusion of system inspection,
testing, or maintenance, the system owner or owners representative shall be informed
in writing within how many hours? ✔✔24 hours

For series circuit involving 240v load and 5 ohms resistor, find current? ✔✔48 Amps

Fire alarm systems shall be provided with at least how many independent & reliable
power sources? ✔✔2

Rule for current in a parallel circuit ✔✔Total current is equal to the sum of the current
through all branches

Th signaling line circuit is a circuit over which multiple input & output signals are carried
out? ✔✔True

The purpose of notification appliance device for fire alarm? ✔✔Get building occupants
attention

The location of the circuit disconnecting means shall be permanently identified at the ?
✔✔Fire Alarm center unit

Circuit integrity cable is estimated by a minimum fire resistance rating of how many
hours? ✔✔2 hours

How long should a water pipe be buried to be used as a grounding pipe? ✔✔10 ft

What is the delay time for ground fault trouble at the main panel? ✔✔200 seconds
$11.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
Gnurse

Conoce al vendedor

Seller avatar
Gnurse NEWCASTLE UNIVERSITY
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
0
Miembro desde
1 año
Número de seguidores
0
Documentos
213
Última venta
-

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes