100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

Massachusetts Oil burner Practice Questions and Answers (100% Correct Answers) Already Graded A+

Puntuación
-
Vendido
-
Páginas
5
Grado
A+
Subido en
21-10-2025
Escrito en
2025/2026

Massachusetts Oil burner Practice Questions and Answers (100% Correct Answers) Already Graded A+

Institución
Massachusetts Oil Burner
Grado
Massachusetts Oil burner









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Massachusetts Oil burner
Grado
Massachusetts Oil burner

Información del documento

Subido en
21 de octubre de 2025
Número de páginas
5
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

1
For Expert help and assignment solutions, +254707240657


Massachusetts Oil burner Practice
Questions and Answers (100% Correct
Answers) Already Graded A+


The cross connection between two supply tanks shall not
exceed?— Ans: 660 gallons
When is an automatic draft control not required?— Ans: When
the equipment is designed to control the draft.
© 2025 Assignment Expert




Combustion performance testing can indicate:— Ans: Improper
air oil mixture, too much combustion air, and low pump pressure.
If a second oil-burning appliance is installed in a single chimney,
Guru01 - Stuvia




you must insure:— Ans: Sufficient draft is available for safe
operation of all connected equipment.
Delayed ignition can be caused by:— Ans: Weak ignition
transformer
You should replace the oil burner nozzle with:— Ans: The
manufacturers recommended nozzle spray pattern and spray
angle.
Viscosity problems can be corrected by:— Ans: Decreasing the
nozzle size and increasing the pump pressure accordingly
The minimum operating pressure of an oil pump is:— Ans: 100 PSI
If a stack relay fails you, must?— Ans: Replace it with an
approved type controller
Aquastats are normally found on what type of heating systems?—
Ans: Hydronic
Airstats are found on what type of heating systems?— Ans:
Forced warm air systems
Under sized returns on a warm air system can result in what?—
Ans: Short cycling of the oil burner

, 2
For Expert help and assignment solutions, +254707240657
Incorrect nozzle selection in regards to gallon per hour, can result
in what problems in a steam system?— Ans: Some radiators not
heating quickly enough
Low boiler water temperature in a hydronic hot water system may
be caused by?— Ans: Undersized oil burner nozzles
Delayed opening oil valves are used to?— Ans: Allow oil pump to
come up to speed
If a steam boiler is to be installed with an automatic feeder it must
also have:— Ans: A backflow prevention device
How can a damaged heat exchanger be detected on a forced
warm air system?— Ans: With a smoke trace candle
© 2025 Assignment Expert




If a high limit is installed to prevent high boiler water temperature,
what is the function of the low limit?— Ans: To maintain
temperature for domestic hot water
Guru01 - Stuvia




On a steam system, a plugged siphon loop can have what affect
on the heating system?— Ans: Insufficient heat in the living space
On a triple acting aquastat a minimum of 20 degrees is
recommend between the high and low limit, this will prevent?—
Ans: The boiler going off on high limit before reaching the
minimum circulator temperature
An advantage of flame retention burner is— Ans: Their high static
pressure enables boilers and furnaces with tighter more efficient
heat exchange passages
The key final adjustment for most oil burners is— Ans: Combustion
air
Dirt or lint buildup in the bevel of the burner fan blades will— Ans:
Reduce the amount of combustion air
To change the air ratio for different firing rates with an adjustable
head burner you— Ans: Adjust the position of the drawer
assembly in the Air tube
All petroleum products are chemical compounds of— Ans:
Hydrogen and carbon
$11.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Guru01 Chamberlain College Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
215
Miembro desde
1 año
Número de seguidores
32
Documentos
20686
Última venta
1 día hace

3.8

36 reseñas

5
15
4
8
3
7
2
1
1
5

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes