The name of the State Agency responsible for enforcing pollution control laws in Texas - CORRECT ANSWER-Texas Commission of Environmental Quality In the activated sludge system, Hydraulic Wash Out can be controlled by - CORRECT ANSWER-flow equalization, Additional clarifier capacity or inflow reduction In the activated sludge system, if the operator observed Boiling action, Violent turbulence throughout the aeration tank surface, Large air bubbles 1/2 inch or greater, the operator would suspect- - CORRECT ANSWER-Over aeration resulting in high DO and or floc shearing therefore the operator should reduce the air SCFM to get DO into the proper range In the activated sludge system if the operator observed uneven surface aeration, dead spots or inadequate mixing in some areas, the operator would suspect - CORRECT ANSWER-Plugged diffusers In the activated sludge system, if the operator observes white thick billowing sudsy foam on the aeration tank, the operator would suspect - CORRECT ANSWER-Overloaded aeration tank and or excessive sludge wasting In the activated sludge system, if the operator observes excessive air being used with no apparent change in organic or hydraulic loading, the operator would suspect - CORRECT ANSWER-Leaks in the system piping, Plugged air diffusers & High organic loading The maximum safe withdrawal rate for a 150 lb chlorine cylinder is - CORRECT ANSWER-40 lbs To determine the approximate number of gallons per day being discharged to the collection system, multiply the population by ____ gallons/person/day. - CORRECT ANSWER-100

Mostrar más Leer menos
Institución
Wastewater Class B Texas
Grado
Wastewater Class B Texas










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Wastewater Class B Texas
Grado
Wastewater Class B Texas

Información del documento

Subido en
21 de octubre de 2025
Número de páginas
21
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Wastewater Class B Texas Exam
Questions With 100% Accurate
Answers Rated A+

The name of the State Agency responsible for enforcing pollution control laws in Texas -
CORRECT ANSWER-Texas Commission of Environmental Quality



In the activated sludge system, Hydraulic Wash Out can be controlled by - CORRECT
ANSWER-flow equalization, Additional clarifier capacity or inflow reduction



In the activated sludge system, if the operator observed Boiling action, Violent
turbulence throughout the aeration tank surface, Large air bubbles 1/2 inch or greater,
the operator would suspect- - CORRECT ANSWER-Over aeration resulting in high DO
and or floc shearing therefore the operator should reduce the air SCFM to get DO into
the proper range



In the activated sludge system if the operator observed uneven surface aeration, dead
spots or inadequate mixing in some areas, the operator would suspect - CORRECT
ANSWER-Plugged diffusers



In the activated sludge system, if the operator observes white thick billowing sudsy foam
on the aeration tank, the operator would suspect - CORRECT ANSWER-Overloaded
aeration tank and or excessive sludge wasting



In the activated sludge system, if the operator observes excessive air being used with
no apparent change in organic or hydraulic loading, the operator would suspect -
CORRECT ANSWER-Leaks in the system piping, Plugged air diffusers & High organic
loading

,The maximum safe withdrawal rate for a 150 lb chlorine cylinder is - CORRECT
ANSWER-40 lbs



To determine the approximate number of gallons per day being discharged to the
collection system, multiply the population by ____ gallons/person/day. - CORRECT
ANSWER-100



The term pathogenic means - CORRECT ANSWER-Capable of causing disease



The minimum separation between sewer lines and potable water lines is - CORRECT
ANSWER-9 feet



A licensed wastewater operator is a professional - CORRECT ANSWER-consistently
does best job possible, practices personal safety, strives to improve job knowledge,
strives to keep the plant and collection system in the best appearance and working
order



An important step in testing a sample for Total Suspended Solids is - CORRECT
ANSWER-Filtering a sample



The Biochemical oxygen Demand (BOD) of a sample is based on - CORRECT
ANSWER-Measuring the dissolved oxygen (DO) used



The results of Biochemical Oxygen Demand (BOD) sample taken at a treatment plant
tells the operator - CORRECT ANSWER-How the plant was operating 5 days ago



Which of the following are dangerous gasses that are likely to be present in lift stations
and manholes? - CORRECT ANSWER-Natural gas, gasoline fumes, hydrogen sulfide
and carbon dioxide

, A preferred hydraulic method of cleaning sewer lines is - CORRECT ANSWER-Hydro
Jet Cleaner



Ways to reduce bad odors coming from a collection system - CORRECT ANSWER-
routinely cleaning slow running or low flow lines, adding chlorine or hydrogen peroxide
to the collection system



Types of pipe that are commonly used in wastewater collection system - CORRECT
ANSWER-ductile iron, Poly Vinyl Chloride (PVC)



Before entering a confined space a worker should - CORRECT ANSWER-Use
approved monitoring device and check for the presence of dangerous gasses, ventilate
the space with a blower, wear a safety harness and attach a life line



A properly designed and operated primary sedimentation tank should remove _____
percent of incoming BOD - CORRECT ANSWER-30-40%



Devices that may be used to determine the level of sewage in a lift station - CORRECT
ANSWER-air bubbler, floats, electrodes, Acoustic (sonic)



What is the most important role of aerobic bacteria in the treatment of wastewater? -
CORRECT ANSWER-decompose organic matter



The hydraulic loading of a trickling filter may be determined by - CORRECT ANSWER-
flow rate and filter area



These can be used to dewater sludge - CORRECT ANSWER-belt press, drying beds,
solid bowl centrifuge, gravity thickener
$11.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
remojudytask Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
81
Miembro desde
2 año
Número de seguidores
30
Documentos
3120
Última venta
6 días hace

3.2

25 reseñas

5
6
4
3
3
11
2
0
1
5

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes