ICC REINFORCED CONCRETE FINAL
CODE TEST- 60 QUESTIONS EXAM
WITH CORRECT QUESTIONS AND
ANSWERS 2025
An acceptable reinforcing steel support mechanism for a 24-inch deep footing are?
-precast dobie blocks
-large,solid pieces of glass
-masonry CMU pieces
-wooden blocks - CORRECT-ANSWERSPrecast dobie blocks
all of the following are true except ?
---Minimum concrete cover for bundled bars of any size need not be greater than 2 inches,
unless they are in a member that's permanently cast against earth
,---specified concrete cover for headed shear stud reinforcement shall not be less then the cover
requirement for the member in which the stud reinforcement is located
---Concrete cover for the flexural members, walls, and compression members with an effective
depth of 8-inches can vary -3/8 of an inch
---Concrete cover for members in highly corrosive environments will typically remain the same
as cast against earth - CORRECT-ANSWERSConcrete cover for members in highly corrosive
environments will typically remain the same as cast agonist earth
As a general rule, Lap splicing bar larger then NO.11 Is?
-not permitted
-permitted
-permitted if bars will be in tension within the structural member
-permitted only if bars are within a bundle - CORRECT-ANSWERSnot permitted
before new concrete is placed, construction joints must be?
, -blown free of dirt and debris
-wetted ,and standing water removed
-sand blasted
- treated with a bonding agent - CORRECT-ANSWERSwetted, and standing water removed
grade 60 reinforcing steel has an ultimate strength of?
-60,000
-75,000
-90,000
-100,000 - CORRECT-ANSWERS90,000 psi
The__________may waive requirements for the employment of a special inspection agency if
he/she finds that the construction is of minor nature.
-building official
-engineer or architect of record
CODE TEST- 60 QUESTIONS EXAM
WITH CORRECT QUESTIONS AND
ANSWERS 2025
An acceptable reinforcing steel support mechanism for a 24-inch deep footing are?
-precast dobie blocks
-large,solid pieces of glass
-masonry CMU pieces
-wooden blocks - CORRECT-ANSWERSPrecast dobie blocks
all of the following are true except ?
---Minimum concrete cover for bundled bars of any size need not be greater than 2 inches,
unless they are in a member that's permanently cast against earth
,---specified concrete cover for headed shear stud reinforcement shall not be less then the cover
requirement for the member in which the stud reinforcement is located
---Concrete cover for the flexural members, walls, and compression members with an effective
depth of 8-inches can vary -3/8 of an inch
---Concrete cover for members in highly corrosive environments will typically remain the same
as cast against earth - CORRECT-ANSWERSConcrete cover for members in highly corrosive
environments will typically remain the same as cast agonist earth
As a general rule, Lap splicing bar larger then NO.11 Is?
-not permitted
-permitted
-permitted if bars will be in tension within the structural member
-permitted only if bars are within a bundle - CORRECT-ANSWERSnot permitted
before new concrete is placed, construction joints must be?
, -blown free of dirt and debris
-wetted ,and standing water removed
-sand blasted
- treated with a bonding agent - CORRECT-ANSWERSwetted, and standing water removed
grade 60 reinforcing steel has an ultimate strength of?
-60,000
-75,000
-90,000
-100,000 - CORRECT-ANSWERS90,000 psi
The__________may waive requirements for the employment of a special inspection agency if
he/she finds that the construction is of minor nature.
-building official
-engineer or architect of record