100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

Florida Building Code – Building 2025 Practice Test with 250 Recently Tested Questions and Correct Answers / FL Building Code Exam Prep Qs and Correct As

Puntuación
-
Vendido
-
Páginas
62
Grado
A+
Subido en
11-10-2025
Escrito en
2025/2026

Florida Building Code – Building 2025 Practice Test with 250 Recently Tested Questions and Correct Answers / FL Building Code Exam Prep Qs and Correct As

Institución
Florida Building Code – Building
Grado
Florida Building Code – Building











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Florida Building Code – Building
Grado
Florida Building Code – Building

Información del documento

Subido en
11 de octubre de 2025
Número de páginas
62
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Florida Building Code – Building 2025 Practice Test with
250 Recently Tested Questions and Correct Answers / FL
Building Code 2025-2026 Exam Prep Qs and Correct As

According to the Florida Building Code, the distance in feet measured from the
building face to the closest interior lot line, to an alley or public way, to the
centerline of a street, or to an imaginary line between two buildings on the same
property is defined as:
A. Property line
B. Building line
C. Fire separation distance
D. Street line - ANSWER-C. Fire separation distance


According to the Florida Building Code, a car wash should be classified under
which Occupancy Group?
A. Group A
B. Group B
C. Group E
D. Group F - ANSWER-B. Group B


Construction or work for which a permit is required shall be subject to inspection
by the:
A. Building official
B. Owner
C. Architect
D. Engineer - ANSWER-A. Building Official




pg. 1

,The ________ shall determine the timing and sequencing of when inspections
occur and what elements are inspected at each inspection:
A. Owner
B. Architect
C. Contractor
D. Building Official - ANSWER-D. Building Official


The building foundation inspection is performed:
A. After trenches are excavated and forms erected and shall at a minimum include
the stem-wall and monolithic slab-on-grade.
B. After trenches are excavated and forms erected and shall at a minimum include
the stem-wall, monolithic slab-on-grade and piling/pile caps.
C. After trenches are excavated and forms erected and shall at a minimum include
the stem-wall, monolithic slab-on-grade, piling/pile caps, footers/grade beams
D. After trenches are excavated and forms erected and shall at a minimum include
the stem-wall, monolithic slab-on-grade, piling/pile caps, footers/grade beams, and
soil termite treatment - ANSWER-C. After trenches are excavated and forms
erected and shall at a minimum include the stem-wall monolithic slab-on-grade,
piling/pile caps, footers/grade beams


According to Florida Building Code, what are the minimum inspections required
for a building (exclusive of electrical, plumbing, mechanical and gas) made by the
Building Official)?
A. Excavation, framing, final and swimming pool
B. Foundation, framing, sheathing, roofing and final
C. Foundation, forms, insulation and final
D. Structural, foundation, framing and dry-in inspection - ANSWER-B.
Foundation, framing, sheathing, roofing and final




pg. 2

,For a typical building under construction, which building inspection usually
precedes the final inspection on the building?
A. Sheathing inspection
B. Framing inspection
C. Roofing inspection
D. Drywall inspection - ANSWER-C. Roofing inspection


According to the Florida Building Code, what is the proper order of the electrical
inspection?
A. Underground inspection, rough-in inspection, final inspection
B. Rough-in inspection, underground inspection, final inspection
C. Underground inspection, final inspection, rough-in inspection
D. Rough-in inspection, final inspection, underground inspection - ANSWER-A.
Underground inspection, rough-in inspection, final inspection


According to Florida Building Code, to prevent the entry of birds, squirrels,
rodents, etc., openings into attic spaces of habitable buildings shall be covered with
screening, hardware cloth or equivalent with openings not exceeding:
A. 1/16"
B. 1/8"
C. 1/4"
D. 1/2" - ANSWER-C. 1/4"
Page 413


According to the Florida Building Code, the minimum corridor width used as a
means of egress for Group 1 - 2, Unrestrained occupancies, requiring the
movement of beds, shall be:
A. 44"

pg. 3

, B. 56"
C. 72"
D. 96" - ANSWER-D. 96"
Page 395


Which of the following is NOT true?
A. A Certificate of Completion allows the tenant to begin occupying spaces in a
shell building
B. A temporary Certificate of Occupancy allows tenants to occupy safe portions of
an incomplete building
C. New buildings may not be occupied until the Building Official issues a
Certificate of Occupancy
D. A Certificate of Completion allows utilities to be hooked up - ANSWER-A. A
Certificate of Completion allows the tenant to begin occupying spaces in a shell
building


What building material is installed to resist the free passage of flame to other areas
of the building through concealed spaces?
A. Fire wall
B. Fire partition
C. Fire damper
D. Fire blocking - ANSWER-D. Fire blocking


A masonry unit in which the net concrete cross-sectional area parallel to the
bearing surface is 75% or more is classified as a:
A. Semi-solid masonry unit
B. Solid masonry unit
C. Hollow core masonry unit

pg. 4
$27.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
muriithikelvin Chamberlain College Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1412
Miembro desde
2 año
Número de seguidores
552
Documentos
2842
Última venta
2 días hace
GOLD-RATED TOP SELLER ON STUVIA – YOUR TRUSTED HUB FOR EXCEPTIONAL STUDY RESOURCES! ACHIEVE MORE WITH EXPERTLY CRAFTED MATERIALS THAT GUARANTEE RESULTS!

Feeling overwhelmed by exams? We’re here to help. Our study materials help you focus, build confidence, and walk into your exams ready. Compiled using real past exams, these resources give you valuable insight into the kinds of questions to expect and how to approach them — helping you maximize your scores and study smarter. Why Choose Us? Gold-rated seller. 1,250+ happy students. Trusted resources for healthcare and certification success. Friendly support whenever you need it.

Lee mas Leer menos
3.9

278 reseñas

5
139
4
55
3
41
2
14
1
29

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes