FSDNY S98 Questions with Detailed Verified Answers



Qualification for S98 certificate of fitness include all except Ans: ✓ ✓ ✓ Must be 21 years of age

If you fail the written test you will not be permitted to Retest for Ans: ✓ ✓ ✓ 90 days

The following is an example of what type of Ceiling Ans: ✓ ✓ ✓ Stooped

A bean is defined as a structural or non structural solid member which could jacks down into the
rooms base more than _____ and is located more than _____ apart on center Ans: ✓ ✓ ✓ Down
more than4" and 3' apart

The following are examples of line type detection except Ans: ✓ ✓ ✓ ionization smoke detector

He could tonight a circuit to which automatic or manual initiating devices are connected where the
signal received does not identify the device operated is called? Ans: ✓ ✓ ✓ A signaling line circuit

Secondary power supplies are required to have sufficient power to operate the fire alarm system in
a non alarm condition for _______ hours and then be capable of operating all notification devices
for a minimum of ______ minutes Ans: ✓ ✓ ✓ 24 hours and 5 minutes

Secondary power supplies for emergency voice evacuation systems are required to have sufficient
power to operate the system in a non along condition for ______ hours and kin be capable of
operating the system during a fire or other emergency for a minimum of ______ minutes Ans: ✓ ✓
✓ 24 hours and 15 minutes under maximum load

Secondary power supply shall automatically provide power to the protected premises fire alarm
system within _______ seconds when ever primary power fails to provide minimum voltage
required for proper operation? Ans: ✓ ✓ ✓ 10 seconds

Cording to NFPA chapter 4, batteries shall be permanently marked with what information? Ans: ✓
✓ ✓ Month and year of manufacture

NFPA 72 "record of completion" is prepared: Ans: ✓ ✓ ✓ upon completion of installation at just
acceptance test

© Get it right 2025 Getaway - Stuvia US All rights reserved

, Click here for more: Scholars nexus
According to NFPA chapter 4, the control panel charging apparatus shall be taken full of recharging
batteries within _____ _____ after batteries have been fully discharged? Ans: ✓ ✓ ✓ 24 hours

According to the fire code of New York City, smoke detectors may be tested by the following
methods except for: Ans: ✓ ✓ ✓ Measured aerosol smoke introduced into the detector

What type of drawing typically shows correct conductor counts? Ans: ✓ ✓ ✓ Riser diagrams

According to the fire code and fire rules, who is responsible for preventing unnecessary and
unwanted alarms? Ans: ✓ ✓ ✓ Owner of a promise or a part thereof

I'll take you way and which according to NFPA chapter 4, a coded alarm signal shall consist of not
less than ______ complete rounds of the number transmitted. Each round shall consist of not less
than a ______ impulses Ans: ✓ ✓ ✓ 3 rounds and 3 impulses

According to the fire rules, who is responsible for making in trees in the smoke detector
maintenance log? Ans: ✓ ✓ ✓ The fire safety director or a person designated by building owners if
no FSD

According to NFPA chapter 4, installation Conductors shall be monitored for integrity. The
occurrence of a single open or single ground fault condition shall be automatically indicated within
______ seconds Ans: ✓ ✓ ✓ 200 seconds

All of the following are good conductors of electricity except Ans: ✓ ✓ ✓ carbon

Which of the following is an example of an initiating device? Ans: ✓ ✓ ✓ Supervisory air pressure
switch and photo electric smoke detector

Into voice along and initiating device which is destroyed as a result of its operation is what type?
Ans: ✓ ✓ ✓ Non restorable

It's the face of the nobleman equipment you shall be designed so that it is capable of performing its
intended function at ______ of its name plate voltage Ans: ✓ ✓ ✓ 85%

When installing heat detectors on ceilings, a row detector shall be located Ans: ✓ ✓ ✓ Within 3' of
the peak

The minimum distance for mounting of a spot type smoke detector from an air supply diffuser is?
Ans: ✓ ✓ ✓ 3' from diffusers

This is regarding manual fire alarm boxes, NFPA 72 requires that they be conspicuous,
unobstructed, and ________ Ans: ✓ ✓ ✓ accessible
© Get it right 2025 Getaway - Stuvia US All rights reserved
$12.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Shinnie University Of California - Berkeley
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
21
Miembro desde
1 año
Número de seguidores
0
Documentos
4018
Última venta
1 semana hace

Here's why you should trust us: Expertly Curated Content: Access high-quality, course-specific exam guides, notes, and practice questions created by Experts. Time-Saving Solutions: Save hours of study time with concise, easy-to-understand materials tailored to key exam topics. Proven Success: Our resources are designed to help you ace exams, boosting grades and confidence. Affordable Excellence: Get exceptional study materials at prices every student can afford.

Lee mas Leer menos
3.6

7 reseñas

5
2
4
2
3
2
2
0
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes