PTAP 1240 - Ultrasound Test Questions with Correct Answers Latest Update ultrasound - Answers -sound waves with a frequency greater than 20,000 hertz -has a thermal/nonthermal effects when applied to the body sound waves enter the body and are attenuated by? - Answers -absorption -reflection -refraction attenuation - Answers gradual decrease in intensity as ultrasound travels through tissue absorption - Answers -some tissues are capable of greater absorption of ultrasound than others -tissue and frequency specific -higher absorption occurs in tissue with a high collagen rate and with higher us frequencies ultrasound energy absorption - Answers best in tendon, ligament, fascia joint capsule and scar tissue reflection of a sound wave - Answers occurs when the wave passes between two tissues and a fraction of the wave "bounces" back refraction - Answers occurs when the US signal is deflected from a straight path and the angle of deflection is away from the transducer coupling agents - Answers gel and water US parameters - Answers -effective radiating area (ERA) -cm2 -beam nonuniformity ratio (BNR)- ratio -intensity- 2 -frequency- MHZ -duty cycle-% effective radiating area (ERA) - Answers -area of the crystal that actually produces sound waves -energy is concentrated near the center -era is always smaller than the total size of the transducer head beam profile - Answers -multiple ways to emerge from the head -energy diverges as it moves away from the source -energy is uniform close to the head (fresnel zone) -becomes less consistent farther away from the head (spatial peak intensity) beam nonuniformity ration (BNR) - Answers -describes amount of variation in the beam -perfect beam would have a BNR of 1:1 ration is between the spatial peak intensity and spatial averaged intensity -high the quality of the crystal, the lower the BMR -lower BNR is more favorable since patients will be less likely to experience hot spots and discomfort during treatment frequency - Answers -selected according to the depth of the tissue to be treated -US delivered at a higher frequency is absorbed more rapidly than US delivered at a lower frequency 3 MHZ - Answers reaches soft tissues 1-2 cm deep 1 MHZ - Answers reaches soft tissues up to 5 cm deep intensity - Answers -measures the quantity of energy delivered per unit area -spatial average intensity: the average intensity of the US input over the area of the transducer; expressed in w/cm2 -selected according to treatment goal -3 MHZ increases tissue temp ~3x faster than 1 MHZ when same duty cycle - Answers portion of treatment time that US is generated during the entire treatment continuous - Answers uninterrupted flow of sound waves; intensity remains constant; 100% used when the goal is to increase tissue temp pulsed - Answers produced by intermittently interrupting the supply of electrical energy to the US head, which causes the sound waves to be discontinuous; 20% most recommended pulsed cycle; used when nonthermal effects desired thermal effects - Answers -increase extensibility of collagen structures -decrease joint stiffness and inflammation -pain relief -increase blood flow -decrease muscle spasms -increased metabolic rate -enhanced immune system response -decreased viscosity of tissue fluids continuous US - Answers -sound waves consist of compression and rarefaction which oscillates particles of material; increases in molecular vibration in the tissue can result in the heat generation -extent of thermal effects is dependent on the intensity, duration and frequency selected

Mostrar más Leer menos
Institución
PTAP 1240
Grado
PTAP 1240









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
PTAP 1240
Grado
PTAP 1240

Información del documento

Subido en
8 de octubre de 2025
Número de páginas
6
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

PTAP 1240 - Ultrasound Test Questions with Correct Answers Latest Update 2025-2026

ultrasound - Answers -sound waves with a frequency greater than 20,000 hertz

-has a thermal/nonthermal effects when applied to the body

sound waves enter the body and are attenuated by? - Answers -absorption

-reflection

-refraction

attenuation - Answers gradual decrease in intensity as ultrasound travels through tissue

absorption - Answers -some tissues are capable of greater absorption of ultrasound than others

-tissue and frequency specific

-higher absorption occurs in tissue with a high collagen rate and with higher us frequencies

ultrasound energy absorption - Answers best in tendon, ligament, fascia joint capsule and scar
tissue

reflection of a sound wave - Answers occurs when the wave passes between two tissues and a
fraction of the wave "bounces" back

refraction - Answers occurs when the US signal is deflected from a straight path and the angle
of deflection is away from the transducer

coupling agents - Answers gel and water

US parameters - Answers -effective radiating area (ERA) -cm2

-beam nonuniformity ratio (BNR)- ratio

-intensity- w.cm2

-frequency- MHZ

-duty cycle-%

effective radiating area (ERA) - Answers -area of the crystal that actually produces sound waves

-energy is concentrated near the center

-era is always smaller than the total size of the transducer head

beam profile - Answers -multiple ways to emerge from the head

-energy diverges as it moves away from the source

, -energy is uniform close to the head (fresnel zone)

-becomes less consistent farther away from the head (spatial peak intensity)

beam nonuniformity ration (BNR) - Answers -describes amount of variation in the beam

-perfect beam would have a BNR of 1:1

ration is between the spatial peak intensity and spatial averaged intensity

-high the quality of the crystal, the lower the BMR

-lower BNR is more favorable since patients will be less likely to experience hot spots and
discomfort during treatment

frequency - Answers -selected according to the depth of the tissue to be treated

-US delivered at a higher frequency is absorbed more rapidly than US delivered at a lower
frequency

3 MHZ - Answers reaches soft tissues 1-2 cm deep

1 MHZ - Answers reaches soft tissues up to 5 cm deep

intensity - Answers -measures the quantity of energy delivered per unit area

-spatial average intensity: the average intensity of the US input over the area of the transducer;
expressed in w/cm2

-selected according to treatment goal

-3 MHZ increases tissue temp ~3x faster than 1 MHZ when same

duty cycle - Answers portion of treatment time that US is generated during the entire treatment

continuous - Answers uninterrupted flow of sound waves; intensity remains constant; 100%
used when the goal is to increase tissue temp

pulsed - Answers produced by intermittently interrupting the supply of electrical energy to the
US head, which causes the sound waves to be discontinuous; 20% most recommended pulsed
cycle; used when nonthermal effects desired

thermal effects - Answers -increase extensibility of collagen structures

-decrease joint stiffness and inflammation

-pain relief

-increase blood flow
$10.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
joshuawesonga22 Liberty University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
36
Miembro desde
8 meses
Número de seguidores
1
Documentos
11111
Última venta
1 día hace
Tutor Wes

Hi there! I'm Tutor Wes, a dedicated tutor with a passion for sharing knowledge and helping others succeed academically. All my notes are carefully organized, detailed, and easy to understand. Whether you're preparing for exams, catching up on lectures, or looking for clear summaries, you'll find useful study materials here. Let’s succeed together!

3.3

3 reseñas

5
1
4
0
3
1
2
1
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes