Backflow Prevention Assembly Tester — Full Practice Exam + Study Guide 2026 | Verified Questions & Answers | Guaranteed Pass

Institución
Backflow Prevention Assembly Tester
Grado
Backflow Prevention Assembly Tester










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Backflow Prevention Assembly Tester
Grado
Backflow Prevention Assembly Tester

Información del documento

Subido en
6 de octubre de 2025
Número de páginas
20
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Backflow Prevention Assembly Tester — Full Practice
Exam + Study Guide 2026 | Verified Questions & Answers
| Guaranteed Pass


What’s Included:

 100+ multiple-choice questions covering all device types (RP, DC, PVB, SVB) and
failure scenarios
 Verified answers with detailed explanations so you understand why answers are correct
 Comprehensive Study Guide, reviewing hydraulics, cross-connection control principles,
regulatory codes, test procedures, diagnostics, maintenance
 Updated 2024 content aligned with the latest standards (USC Manual, AWWA / ABPA
references)
 Tips, shortcuts & exam strategies to maximize your score
 Downloadable PDF + printable formats

Why choose this package?

 Contains realistic, exam-style questions (not just superficial ones)
 Designed by certified backflow testers and instructors
 Helps you identify weak areas and reinforce understanding
 Good for initial certification and recertification
 Supports multiple jurisdictions (with core theory that applies widely)




BACKFLOW PREVENTION ASSEMBLY TESTER PRACTICE EXAM

A mixture of air and gas is considered hazardous when the mixture exceeds what percentage of gthe
lower explosive limit

(A) 0%
(B) 3%
(C) 7%
(D) 10%

10%

To exert a pressure of 1.0 psi at base of a water column the column would have to be

(A) 4.34 high

,(B) 14.7 high
(C) 27.75 high
(D) 33.89 high

27.75 high

A DC must be tested

(A) Upon installation
(B) Every 6 month
(C) Annually on a health hazard
(D) none of the above

Upon installation

In responding to a backflow incident the water purveyor should

(A) Call the mayor
(B) Implement the emergency response plan
(C) Install a vacuum breaker
(D) Develop a good excuse

Implement the emergency response plan



An absolute perssure of 25 psiaa (at sea level) is equal to approximately

(A) 5 psi
(B) 10 psi
(C) 20 psi
(D) 25 psi

10 psi

Dueing a field test the air inlet on PVB must open at

(A) Above 2.0 psid
(B) Below 1.0 psid
(C) Above 1.0 psid
(D) Below 2.0 psid

Above 1.0 psid

A differential pressuer gauge is used to field test

(A) PVB's
(B) Dual Checks

, (C) AVB's
(D) All the above

PVB's

Backflow in a water supply can be caused by

(A) Backpressure only
(B) A Barometric Loop
(C) Backsiphonage only
(D) Backpressure and Backsiphonage

Backpressure and Backsiphonage

A BPAT tester is required to report test information on the proper forms to the

(A) Administrative authority
(B) Manufacturer's Rep
(C) EPA
(D) None of the above

Administrative authority

The relief valve opens when closing #2 shut off valve on a RP What is the most probable cause

(A) #1 Shut off valve is open
(B) #2 Shut off valve is open
(C) #1 check is fouled open
(D) Shut off is leaking

#1 check is fouled open

When field testing the #1 Check of a RP the differential pressurw shouid be

(A) Greter than or equal to 5.0 psid
(B) 3.0 psid greater than the relief valve opening point
(C) 1.0 psid in the directiom of flow
(D) Less than 5.0 psid

Greter than or equal to 5.0 psid

When testing a SVB what is the firsrt test being performed

(A) The air inlet opening point
(B) The static pressure across the check valve
(C) To verify the #2shut off hold tight
(D) To check if the SVB hold water

The static pressure across the check valve
$22.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
studyguidepro NURSING
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
33
Miembro desde
3 meses
Número de seguidores
2
Documentos
1146
Última venta
1 día hace
verified exams

Updated exams .Actual tests 100% verified.ATI,NURSING,PMHNP,TNCC,USMLE,ACLS,WGU AND ALL EXAMS guaranteed success.Here, you will find everything you need in NURSING EXAMS AND TESTBANKS.Contact us, to fetch it for you in minutes if we do not have it in this shop.BUY WITHOUT DOUBT!!!!Always leave a review after purchasing any document so as to make sure our customers are 100% satisfied. **Ace Your Exams with Confidence!**

2.3

3 reseñas

5
1
4
0
3
0
2
0
1
2

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes