Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Examen

NFPA 211 - Journeyman Exam Practice Test Solutions

Puntuación
-
Vendido
-
Páginas
5
Grado
A+
Subido en
29-09-2025
Escrito en
2025/2026

NFPA 211 - Journeyman Exam Practice Test Solutions ._______________ is a structure containing one or more vertical or near vertical passageways for conveying flue gases to the outside atmosphere. - Answer-A chimney. NFPA 211 3.3.28.1.1 .A barometric draft regulator if used shall be installed _______? - Answer-In the same room or enclosure as the appliance. NFPA 211 9.11.3 .A barometric draft regulator, if used, shall be installed where? - Answer-In the same room or enclosure as the appliance in such a manner that no difference in pressure between the air in the vicinity of the regulator and the combustion air supply will be permitted. NFPA 211 9.11.3 .A chamber in which heat resulting directly from the combustion of fuel is transferred through the walls of the chamber to air passing through is called a _______? - Answer-Heat exchanger NFPA 211 3.3.87 .A chimney cap is used to ________? - Answer-Provide a protective covering for the top of the chimney to prevent entry of rain, snow, animals and birds and to prevent downdrafts. .A chimney connector shall be? - Answer-As short and straight as practicable. NFPA 211 9.3 .A fixed or removable ring tube or lining usually located in the hole where the chimney connector or vent connector passes through a wall or enters a chimney or vent is called a ? - Answer-Thimble. NFPA 211 3.3.132

Mostrar más Leer menos
Institución
NFPA 211 - Journeyman
Grado
NFPA 211 - Journeyman

Vista previa del contenido

NFPA 211 - Journeyman Exam Practice
Test Solutions

\._______________ is a structure containing one or more vertical or near vertical passageways
for conveying flue gases to the outside atmosphere. - Answer- A chimney. NFPA 211
3.3.28.1.1



\.A barometric draft regulator if used shall be installed _______? - Answer- In the same room
or enclosure as the appliance. NFPA 211 9.11.3



\.A barometric draft regulator, if used, shall be installed where? - Answer- In the same room
or enclosure as the appliance in such a manner that no difference in pressure between the air in
the vicinity of the regulator and the combustion air supply will be permitted. NFPA 211 9.11.3



\.A chamber in which heat resulting directly from the combustion of fuel is transferred through
the walls of the chamber to air passing through is called a _______? - Answer- Heat
exchanger NFPA 211 3.3.87



\.A chimney cap is used to ________? - Answer- Provide a protective covering for the top of
the chimney to prevent entry of rain, snow, animals and birds and to prevent downdrafts.



\.A chimney connector shall be? - Answer- As short and straight as practicable. NFPA 211 9.3



\.A fixed or removable ring tube or lining usually located in the hole where the chimney
connector or vent connector passes through a wall or enters a chimney or vent is called a ? -
Answer- Thimble. NFPA 211 3.3.132

, \.A fuel-burning appliance for heating water to a temperature not more than 200F is known as a
_____________? - Answer- Water heater. NFPA 211 3.3.88.4



\.A self-contained heating appliance that is intended for the heating of a space in which it is
installed is known as a ______? - Answer- Unit heater. NFPA 211 3.3.88.3



\.A vertical or nearly vertical vent composed of factory-built components conveying gases from
oil and gas appliances or their vent connectors to the outside atmosphere. - Answer- Type L
vent. NFPA 211 3.3.142.3



\.Automatically operated dampers shall meet what criteria? - Answer- They shall be listed
and they shall be installed by a qualified installer. NFPA 211 9.9.4



\.Chimney selection is based on tupe of appliance connected, fuel used, and pressure within the
chimney and ______? - Answer- The temperature of the flue gas at the appliance outlet.
NFPA 211 5.2.1



\.Clean out openings must be made from? - Answer- Ferrous metal, stainless steel, precast
cement or other approved non-combustible doors and frames. NFPA 211 7.1.4.2



\.Cleanout doors shall be permanently marked with a message equivalent to the following. -
Answer- Warning: do not obstruct. Keep combustible material at least 18" away from this
door. NFPA 211 7.1.4.6



\.Connectors shall maintain a pitch or rise of? - Answer- At least 1/4 inch per foot of the
horizontal length of pipe from the appliance to the chimney. NFPA 211 9.7.7



\.Constituents resulting from the combustion of a fuel with oxygen of the air including the inert
but excluding excess air. - Answer- Combustion products. NFPA 211 3.3.45

Escuela, estudio y materia

Institución
NFPA 211 - Journeyman
Grado
NFPA 211 - Journeyman

Información del documento

Subido en
29 de septiembre de 2025
Número de páginas
5
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$8.19
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
IszackBd University Of Washington
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
39
Miembro desde
1 año
Número de seguidores
3
Documentos
5564
Última venta
1 semana hace
IszackBd Stuvia

Our store offers a wide selection of materials on various subjects and difficulty levels, created by experienced teachers. We specialize on NURSING,WGU,ACLS USMLE,TNCC,PMHNP,ATI and other major courses, Updated Exam, Study Guides and Test banks. If you don\'t find any document you are looking for in this store contact us and we will fetch it for you in minutes, we love impressing our clients with our quality work and we are very punctual on deadlines. Please go through the sets description appropriately before any purchase and leave a review after purchasing so as to make sure our customers are 100% satisfied. FOR ANY REQUEST FEEL FREE TO REACH US

Lee mas Leer menos
5.0

3 reseñas

5
3
4
0
3
0
2
0
1
0

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes