100- SOLVED Newest 2025
According to "The Act, What is the mission of OSHA? - ✔✔✔(Protect American Workers) -
To assure safe and healthful working conditions for working men and women by setting and enforcing
standards and by providing training, outreach, education and assistance.
Citations and Penalties - ✔✔✔Willfull
Serious
Other-than Serious
Repeated
Construction Fatal Four - ✔✔✔Falls
Struck By Objects
Electrocutions
Caught-in-between
Define "Type B" soil. - ✔✔✔(i) Cohesive soil with an unconfined compressive strength greater than (0.5
tsf but less than 1.5 tsf).
Define Assured Equipment Grounding Conductor program - ✔✔✔1926.404(b)(1)(iii)
Conductor program on construction sites covering all cord sets, receptacles which are (not a part of the
permanent wiring of the building or structure), and equipment connected by cord and plug.
Define Bonding? - ✔✔✔1926.449
The permanent (joining of metallic parts to form an electrically conductive path) which will assure
electrical continuity and the capacity to conduct safely any current likely to be imposed.
, Define Creating Employer - ✔✔✔The employer that caused a hazardous condition that violates an OSHA
standard.
Employer must report to OSHA - ✔✔✔All work-related fatalities within 8hrs
and all inpatient hospitalization, amputations and losses of an eye within 24hrs.
How do you protect employee and other employees vision in the vicinity during Arc Welding
operations? - ✔✔✔1926.351(e)
("Shielding"). Whenever practicable, all arc welding and cutting operations shall be shielded by
noncombustible or flameproof screens which will protect employees and other persons working in the
vicinity from the direct rays of the arc.
How far can a Class (A) fire extinguishers be away from the employees? - ✔✔✔1926.150(c)(1)(i)
A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected
building area, or major fraction thereof. Travel distance from any point of the protected area to the
nearest fire extinguisher shall not exceed (100 feet).
How should drinking water be dispensed from portable containers? - ✔✔✔1926.51(a)(2)
Portable containers used to dispense drinking water shall be capable of being (tightly closed, and
equipped with a tap. Water shall not be dipped from containers).
How should PFAS be rigged? - ✔✔✔1926.502(d)(16)(v)
have sufficient strength to withstand twice the potential impact energy of an employee (free falling a
distance of 6 feet), or the free fall distance permitted by the system, whichever is less.
IAW 1926.1419, during operations when is the operator required to safely stop operations? -
✔✔✔1926.1419(f)
During operations requiring signals, the ability to transmit signals between the operator and signal
person must be maintained. If that ability is interrupted at any time, the operator must safely stop
operations requiring signals until it is reestablished and a proper signal is given and understood.