Med Gas Exam Questions With Reviewed 100% Correct Detailed Answers Guaranteed Pass!!Current Update In a Category 1 Dental and Gas Vacuum Piping system, which of the following is an NFPA 99 requirement for the labeling of pipes? - Answer- Color coding & non-standard pressure Which of the following treatments shall be performed before brazing cut ends of a tube to be installed in a medical gas piping system? - Answer- Cut ends shall be rolled smooth or deburred Manifolds for gas cylinders shall actuate a(an) _______ signal and shall activate an indicator at all _______ alarm panels to indicate when or just before changeover from one header to the other. - Answer- Local, master When is the initial pressure test conducted, by a medical gas installer, on a nitrous oxide system? - Answer- After blowdown of a distribution piping In those portions of systems intended to handle oxygen at pressures greater than 350 psi the interconnecting hose shall NOT contain ________ materials? - Answer- Polymeric In a non-anesthetizing area, on which side of a zone valve shall the pressure/vacuum sensor be located? - Answer- Station outlet/inlet What is the purpose of using an oxygen analyzer during the piping purge prior to brazing? - Answer- Assure that all ambient air has been removed from the pipeline A medical gas master or area alarm panel shall be set to actuate a(an) _____ indicator when the communication with an alarm-initiating device is disconnected. - Answer- Audible and visual When an EOSC becomes the temporary supply source, a facility will monitor the system by use of which of the following? - Answer- Providing four connection points to both master alarms Which of the following conditions must be met where medical gas and vacuum systems are installed by non-certified personnel? - Answer- installation by anyone other than 6010 certified personnel is NOT permitted Which of the following systems shall NOT be permitted to be located in an outdoor enclosure? - Answer- Medical air compressor supply sources Metallic flexible joints are being used in the pipeline for vibration control. Which of the following is NOT required of such joints? - Answer- suitable for service at 150 psig or above who shall witness the installer-performed standing vacuum test? - Answer- the authority having jurisdiction, or its designee the medical air compressor intake shall be located a minimum of how many feet from any exhaust or plumbing vents? - Answer- 25 feet the gas produced by evaporation from the secondary header in a cryogenic liquid cylinder system shall enter the supply system ________ of the final line regulator. - Answer- upstream with the approval of the Authority Having Jurisdiction, in which areas shall the zone valves be permitted to be secured to prevent inappropriate access? - Answer- pediatric factory installed inlet tubes on station outlets shall be NOT less than __________with 0.3 inch minimum inside diameter. - Answer- NPS 1/4, 3/8 in. O.D. which of these operations would not breach the vacuum system? - Answer- testing a system component with a leak detector solution except for valves in zone valve boxes, all valves shall be located in secured areas such as locked pipe chases, or be __________. - Answer- latched or locked in operation position medical gas Central Supply systems are NOT permitted to be located where? - Answer- in an unlocked location fittings, valves, and other components for field-installed positive pressure distribution systems shall be ________ until prepared for installation. - Answer- delivered sealed, labeled, and kept sealed vacuum piping for __________ shall be connected separately from the medical surgical system directly to the receiver tank through its own isolation valve and fluid trap located at the receiver. - Answer- a teaching laboratory NFPA 99 specifies that the medical gas piping system shall be protected against all EXCEPT which of the following? - Answer- exposure to liquids category 1 support gasses carry which of these additional hazards? - Answer- higher pressures manufactured assemblies for medical gas systems employing flexible hose shall use flexible connectors with a minimum burst gauge pressure of how many psi? - Answer- 1000 an assembly of equipment that holds a capacity of oxygen greater than ____________ is defined as a Bulk Oxygen System - Answer- 20,000 ft^3 what does it mean when equipment, material or services are shows as "listed"? - Answer- they are identified and published by an organization that is acceptable to the authority having jurisdiction under which of these conditions shall instrument air reserve header cylinders be permitted to be stored with the instrument air compressor? - Answer- the only motor-driven machinery in the rooms is for the instrument air equipment. which type of copper tube hangers shall be used in a potentially damp location? - Answer- plastic coated stainless tubes may be joined by any methods EXCEPT which of the following? - Answer- Braze gas storage for Central Supply Systems required specialized knowledge and consideration of information in the NFPA 55 for locating, installing and inspection of which of the following? - Answer- Bulk Gas all pressure relief valves shall be made of ______ brass, or bronze. - Answer- stainless steel the reserve header in a cryogenic liquid cylinder manifold system shall have sufficient cylinder connections for one average day's supply, but NOT fewer than how many connections? - Answer- 3 all fittings for medical gas work shall be kept separate from other tools and kept free of grease or oil. If cleaned, only a degreaser such as __________ is permitted. - Answer- trisodium phosphate or sodium carbonate with potable water station outlets/inlets shall be identified as to the ________ for the specific gas or vacuum provided. - Answer- name or chemical symbol when brazing, joints shall be continuously purges with oil-free, dry nitrogen NF to prevent the formation of __________ on the inside surfaces of the joint. - Answer- copper oxide a bulk cryogenic supply contains parallel-piped duplex line regulators. Which of the following is a requirement for controls for line pressure? - Answer- a balanced design

Mostrar más Leer menos
Institución
Med Gas
Grado
Med Gas

Vista previa del contenido

Med Gas Exam Questions With
Reviewed 100% Correct Detailed
Answers Guaranteed Pass!!Current
Update
In a Category 1 Dental and Gas Vacuum Piping system, which of the following is an
NFPA 99 requirement for the labeling of pipes? - Answer- Color coding & non-standard
pressure

Which of the following treatments shall be performed before brazing cut ends of a tube
to be installed in a medical gas piping system? - Answer- Cut ends shall be rolled
smooth or deburred

Manifolds for gas cylinders shall actuate a(an) _______ signal and shall activate an
indicator at all _______ alarm panels to indicate when or just before changeover from
one header to the other. - Answer- Local, master

When is the initial pressure test conducted, by a medical gas installer, on a nitrous
oxide system? - Answer- After blowdown of a distribution piping

In those portions of systems intended to handle oxygen at pressures greater than 350
psi the interconnecting hose shall NOT contain ________ materials? - Answer-
Polymeric

In a non-anesthetizing area, on which side of a zone valve shall the pressure/vacuum
sensor be located? - Answer- Station outlet/inlet

What is the purpose of using an oxygen analyzer during the piping purge prior to
brazing? - Answer- Assure that all ambient air has been removed from the pipeline

A medical gas master or area alarm panel shall be set to actuate a(an) _____ indicator
when the communication with an alarm-initiating device is disconnected. - Answer-
Audible and visual

When an EOSC becomes the temporary supply source, a facility will monitor the system
by use of which of the following? - Answer- Providing four connection points to both
master alarms

Which of the following conditions must be met where medical gas and vacuum systems
are installed by non-certified personnel? - Answer- installation by anyone other than
6010 certified personnel is NOT permitted

,Which of the following systems shall NOT be permitted to be located in an outdoor
enclosure? - Answer- Medical air compressor supply sources

Metallic flexible joints are being used in the pipeline for vibration control. Which of the
following is NOT required of such joints? - Answer- suitable for service at 150 psig or
above

who shall witness the installer-performed standing vacuum test? - Answer- the authority
having jurisdiction, or its designee

the medical air compressor intake shall be located a minimum of how many feet from
any exhaust or plumbing vents? - Answer- 25 feet

the gas produced by evaporation from the secondary header in a cryogenic liquid
cylinder system shall enter the supply system ________ of the final line regulator. -
Answer- upstream

with the approval of the Authority Having Jurisdiction, in which areas shall the zone
valves be permitted to be secured to prevent inappropriate access? - Answer- pediatric

factory installed inlet tubes on station outlets shall be NOT less than __________with
0.3 inch minimum inside diameter. - Answer- NPS 1/4, 3/8 in. O.D.

which of these operations would not breach the vacuum system? - Answer- testing a
system component with a leak detector solution

except for valves in zone valve boxes, all valves shall be located in secured areas such
as locked pipe chases, or be __________. - Answer- latched or locked in operation
position

medical gas Central Supply systems are NOT permitted to be located where? - Answer-
in an unlocked location

fittings, valves, and other components for field-installed positive pressure distribution
systems shall be ________ until prepared for installation. - Answer- delivered sealed,
labeled, and kept sealed

vacuum piping for __________ shall be connected separately from the medical surgical
system directly to the receiver tank through its own isolation valve and fluid trap located
at the receiver. - Answer- a teaching laboratory

NFPA 99 specifies that the medical gas piping system shall be protected against all
EXCEPT which of the following? - Answer- exposure to liquids

category 1 support gasses carry which of these additional hazards? - Answer- higher
pressures

, manufactured assemblies for medical gas systems employing flexible hose shall use
flexible connectors with a minimum burst gauge pressure of how many psi? - Answer-
1000

an assembly of equipment that holds a capacity of oxygen greater than ____________
is defined as a Bulk Oxygen System - Answer- 20,000 ft^3

what does it mean when equipment, material or services are shows as "listed"? -
Answer- they are identified and published by an organization that is acceptable to the
authority having jurisdiction

under which of these conditions shall instrument air reserve header cylinders be
permitted to be stored with the instrument air compressor? - Answer- the only motor-
driven machinery in the rooms is for the instrument air equipment.

which type of copper tube hangers shall be used in a potentially damp location? -
Answer- plastic coated

stainless tubes may be joined by any methods EXCEPT which of the following? -
Answer- Braze

gas storage for Central Supply Systems required specialized knowledge and
consideration of information in the NFPA 55 for locating, installing and inspection of
which of the following? - Answer- Bulk Gas

all pressure relief valves shall be made of ______ brass, or bronze. - Answer- stainless
steel

the reserve header in a cryogenic liquid cylinder manifold system shall have sufficient
cylinder connections for one average day's supply, but NOT fewer than how many
connections? - Answer- 3

all fittings for medical gas work shall be kept separate from other tools and kept free of
grease or oil. If cleaned, only a degreaser such as __________ is permitted. - Answer-
trisodium phosphate or sodium carbonate with potable water

station outlets/inlets shall be identified as to the ________ for the specific gas or
vacuum provided. - Answer- name or chemical symbol

when brazing, joints shall be continuously purges with oil-free, dry nitrogen NF to
prevent the formation of __________ on the inside surfaces of the joint. - Answer-
copper oxide

a bulk cryogenic supply contains parallel-piped duplex line regulators. Which of the
following is a requirement for controls for line pressure? - Answer- a balanced design

Escuela, estudio y materia

Institución
Med Gas
Grado
Med Gas

Información del documento

Subido en
25 de septiembre de 2025
Número de páginas
20
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$22.29
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Stuviaascorers University of Washington
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
375
Miembro desde
3 año
Número de seguidores
185
Documentos
11059
Última venta
1 día hace
StuviaAscorers | Top Study Notes & Exam Solutions

Stuviaascorers – Your #1 Source for Top-Quality Study Materials! Struggling with exams? Stuviaascorers has got you covered! I provide expertly crafted study notes, summaries, past papers, and exam-ready answers to help you pass with flying colors. My materials are designed for clarity, accuracy, and success—so you can study smarter, not harder! Why Choose My Study Materials? Well-structured & easy to understand – No fluff, just what you need! Exam-focused & high-scoring content – Get straight to the point! Accurate answers & clear explanations – Learn with confidence! Save time & boost your grades – Study efficiently! Don’t leave your success to chance! Browse my documents and start acing your exams today!

Lee mas Leer menos
3.7

67 reseñas

5
31
4
11
3
12
2
2
1
11

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes