100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

Hemodynamic monitoring Exam Latest Updated Solved 100% Correct

Puntuación
-
Vendido
-
Páginas
2
Grado
A+
Subido en
24-09-2025
Escrito en
2025/2026

Hemodynamic monitoring Exam Latest Updated Solved 100% Correct What does an arterial line measure? - Answer- Continuous systolic, diastolic, and MAP (direct BP measurement) Allen's Test purpose? - Answer- Assess ulnar circulation before radial artery line insertion Phlebostatic axis location? - Answer- 4th ICS, mid-axillary line (level of right atrium) Transducer above phlebostatic axis = ? - Answer- Readings falsely low Transducer below phlebostatic axis = ? - Answer- Readings falsely high Pressure bag setting? - Answer- 300 mmHg Arterial line complication risks? - Answer- Accidental blood loss, infection, impaired circulation Normal CVP? - Answer- 2-6 mmHg ↑ CVP causes? - Answer- Overhydration, HF, pulmonary stenosis, venous congestion, positive pressure ventilation ↓ CVP causes? - Answer- Hypovolemia, hemorrhage, dehydration CVP complications? - Answer- Infection, thrombosis, pneumothorax, air embolism Treatment for air embolism? - Answer- Place on left side, Trendelenburg, withdraw air via syringe, give oxygen What does swan ganz indirectly measure? - Answer- LVEDP (via PCWP) Normal Pulmonary Artery Pressure (PAP)? - Answer- 15-25 systolic / 8-15 diastolic mmHg Normal PCWP (wedge pressure)? - Answer- 6-12 mmHg Normal SVO₂? - Answer- 70-80% Low SVO₂ means? - Answer- Inadequate O₂ delivery → ↓ CO, ↓ Hgb, hypoxemia, ↑ O₂ demand High SVO₂ means? - Answer- ↓ O₂ extraction by tissues (sepsis, sedation, hyperdynamic state) Normal CO? - Answer- 4-8 L/min Normal CI? - Answer- 2-4 L/min High CO/CI seen in? - Answer- Sepsis (peripheral vasodilation)

Mostrar más Leer menos
Institución
Hemodynamic Monitoring
Grado
Hemodynamic monitoring








Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Hemodynamic monitoring
Grado
Hemodynamic monitoring

Información del documento

Subido en
24 de septiembre de 2025
Número de páginas
2
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Hemodynamic monitoring Exam
Latest Updated Solved 100% Correct
What does an arterial line measure? - Answer- Continuous systolic, diastolic, and MAP
(direct BP measurement)

Allen's Test purpose? - Answer- Assess ulnar circulation before radial artery line
insertion

Phlebostatic axis location? - Answer- 4th ICS, mid-axillary line (level of right atrium)

Transducer above phlebostatic axis = ? - Answer- Readings falsely low

Transducer below phlebostatic axis = ? - Answer- Readings falsely high

Pressure bag setting? - Answer- 300 mmHg

Arterial line complication risks? - Answer- Accidental blood loss, infection, impaired
circulation

Normal CVP? - Answer- 2-6 mmHg

↑ CVP causes? - Answer- Overhydration, HF, pulmonary stenosis, venous congestion,
positive pressure ventilation

↓ CVP causes? - Answer- Hypovolemia, hemorrhage, dehydration

CVP complications? - Answer- Infection, thrombosis, pneumothorax, air embolism

Treatment for air embolism? - Answer- Place on left side, Trendelenburg, withdraw air
via syringe, give oxygen

What does swan ganz indirectly measure? - Answer- LVEDP (via PCWP)

Normal Pulmonary Artery Pressure (PAP)? - Answer- 15-25 systolic / 8-15 diastolic
mmHg

Normal PCWP (wedge pressure)? - Answer- 6-12 mmHg

Normal SVO₂? - Answer- 70-80%

Low SVO₂ means? - Answer- Inadequate O₂ delivery → ↓ CO, ↓ Hgb, hypoxemia, ↑ O₂
demand
$8.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Stuviaascorers University of Washington
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
339
Miembro desde
2 año
Número de seguidores
185
Documentos
9994
Última venta
2 semanas hace
StuviaAscorers | Top Study Notes & Exam Solutions

Stuviaascorers – Your #1 Source for Top-Quality Study Materials! Struggling with exams? Stuviaascorers has got you covered! I provide expertly crafted study notes, summaries, past papers, and exam-ready answers to help you pass with flying colors. My materials are designed for clarity, accuracy, and success—so you can study smarter, not harder! Why Choose My Study Materials? Well-structured & easy to understand – No fluff, just what you need! Exam-focused & high-scoring content – Get straight to the point! Accurate answers & clear explanations – Learn with confidence! Save time & boost your grades – Study efficiently! Don’t leave your success to chance! Browse my documents and start acing your exams today!

Lee mas Leer menos
3.8

61 reseñas

5
29
4
11
3
10
2
1
1
10

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes