1. One of the significant causes of leaks in underground liquid storage systems is ____________ ________________ - ANSWER -Improper Installation 2. Written Plans are required to - ANSWER -obtain permits, solicit bids, and provide precise guidance for installers. 3. The plans should - ANSWER -Describe the property, identify the size and location of the tanks, indicate the liquids to be stored and provide the location of the dispensers and piping. 4. Storage systems discussed in this recommended practice are usually regulated by - ANSWER -Federal, state or local agencies. 5. All owners should ensure that the equipment to be installed meets - ANSWER - applicable regulatory requirements before being installed 6. Consult the local authorities who have jurisdiction

Mostrar más Leer menos
Institución
U1 UST Installation/Retrofitting
Grado
U1 UST Installation/Retrofitting









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
U1 UST Installation/Retrofitting
Grado
U1 UST Installation/Retrofitting

Información del documento

Subido en
18 de septiembre de 2025
Número de páginas
12
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

U1 UST Installation/Retrofitting Questions And Answers
1. One of the significant causes of leaks in 9. Tanks must not be dropped, dragged, or
underground liquid storage systems is handled with sharp objects to avoid -
____________ ________________ - ANSWER -Damage to the tank
ANSWER -Improper Installation

10. The only time tanks really should be moved is
2. Written Plans are required to - when - ANSWER -for inspections and
ANSWER -obtain permits, solicit bids, and testing.
provide precise guidance for installers.

11. If a tanks is damaged at all throughout the
3. The plans should - ANSWER -Describe moving process it must be - ANSWER -
the property, identify the size and location of the Repaired in accordance with the manufacture's
tanks, indicate the liquids to be stored and instructions.
provide the location of the dispensers and piping.

12. The proper way to move a tank is by lifting it,
4. Storage systems discussed in this using the - ANSWER -Lift lugs that are
recommended practice are usually regulated by - installed by the manufacturer.
ANSWER -Federal, state or local agencies.

13. Tanks should be carefully lifted and lowered
5. All owners should ensure that the equipment using - ANSWER -Cables or chains of
to be installed meets - ANSWER - adequate length.
applicable regulatory requirements before being
installed
14. When two lifting lugs are being used, the
angle between the lifting cable and vertical
6. Consult the local authorities who have should be no more than - ANSWER -30
jurisdiction in the area before storage-system degrees.
plans are - ANSWER -finalized or
construction is initiated.
15. Stockpile piping materials and equipment in a
_____________ _________ on the job site -
7. All owners should ensure that the equipment ANSWER -Secure area
to be installed meets all applicable regulatory
requirements before - ANSWER -Being
installed. 16. Confirm adherence to specifications by
reporting to the owner about any -
ANSWER -detected damage that could
8. To avoid damage tanks must not be - result in leakage or premature corrosion.
ANSWER -dropped, dragged, or handled
with sharp objects.
17. Pressure test single-walled tanks with _____
to _______ psig air pressure, soaping all


, U1 UST Installation/Retrofitting Questions And Answers
surfaces, seams and fittings while inspecting for 26. Since the best accuracy of gauges is at mid-
bubbles. - ANSWER -3 to 5 range, and test pressures must not exeed 5 psig,
use a gauge with a maximum limit of ____ or
______ - ANSWER -10 or 15 psig
18. Air testing with over ___ psig (3 Psig for 12-
Ft. Diameter FRP tanks) is hazardous and may
damage the tank - ANSWER -5 psig 27. Check the gauges __________ and
_________ before use - ANSWER -
operation and accuracy
19. Do not air test a tank that has previously
contained - ANSWER -flammable or
combustible liquids 28. Underground storage systems may include
vapor-recovery - ANSWER -Piping and
equipment
20. Place ______ barricades at the ends of tanks
being tested. - ANSWER -Warning
29. What can cause premature storage-system
failures _________ - ANSWER -Debris and
21. Avoid tank ends, man-ways, and fittings while other foreign materials
the tank is under - ANSWER -Pressure

30. Tank installers should have gone through
22. Release pressure in the tank before training programs to improve their skills and
disconnecting any - ANSWER -gauges or insure the install is __________ -
test fittings. ANSWER -Successful


23. Be aware some manufactures do not tighten 31. __________ kinds of plans are required to
fittings to allow for _____________ obtain permits, solicit bids, and provide precise
_____________ during shipping and storage. - guidance for installers - ANSWER -written
ANSWER -Temperature changes

32. ___________________ should insure that
24. True or False: Air tests are inconclusive the equipment to be installed meets all applicable
without soaping and careful inspection for regulatory requirements before beginning an
bubbles? - ANSWER -True installation - ANSWER -Owners


25. Tanks gauges must have a scale that will 33. Tanks should be ___________ inspected
permit detection of small changes in __________ before installation - ANSWER -Visually
that might go undetected on gauges with a
___________ _________. - ANSWER -
Pressure, broader range. 34. 2 Gauges should be used to reduce
___________ ____________ - ANSWER -
gauge failure
$13.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
MERCYTRISHIA Howard Community College
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
180
Miembro desde
1 año
Número de seguidores
35
Documentos
10792
Última venta
22 horas hace
MercyTrishia

On this page, you find all documents, package deals offered by seller MercyTrishia

3.8

37 reseñas

5
16
4
7
3
10
2
0
1
4

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes