100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

BICSI CONNECT RCDD V01 QUESTIONS WITH 100% ACCURATE ANSWERS

Puntuación
-
Vendido
-
Páginas
10
Grado
A+
Subido en
16-09-2025
Escrito en
2025/2026

BICSI CONNECT RCDD V01 QUESTIONS WITH 100% ACCURATE ANSWERS

Institución
BISCI
Grado
BISCI









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
BISCI
Grado
BISCI

Información del documento

Subido en
16 de septiembre de 2025
Número de páginas
10
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

BICSI CONNECT RCDD V01 QUESTIONS WITH
100% ACCURATE ANSWERS
What type of fluctuation is caused by a decrease in the nominal voltage or current for more than 3600
cycles (one minute)? - Accurate answers Undervoltage

What is the maximum recommended length for a telecommunications bonding conductor (TBC)? -
Accurate answers 9 m (30ft)

You have been hired as a consultant for a property management firm that would like to implement a
telecommunications administration system in one of its properties. The property in question is a twelve-
story office building with multiple tenants. Which class of administration is best suited for this type of
infrastructure? - Accurate answers Class 2

Which device is used to manage resources that are shared by users and administrators on a network? -
Accurate answers Server

How much space must be allocated for an equipment room in a building that has 9300 m2 (100,000 ft2)
of usable floor space and a total floor area of 13,935 m2 (150,000 ft2)? - Accurate answers 83.8 m2
(900 ft2)

You do not have much space. As a result, which type of fiber termination connectors should you use to
design a horizontal crossconnect/floor distributor (HC/FD) where you will be terminating OM4 optical
fiber cable? - Accurate answers LC

Which of the following telecommunications infrastructure elements requires an identifier in a Class 1
system? - Accurate answers Horizontal link

What is the minimum separation distance that must be maintained between transformers and a 5 kVA
transformer? - Accurate answers 1220 mm (48 in)

Which of the following gigabit passive optical networks (GPONs) has a maximum supported distance of
60 km (37 mi)? - Accurate answers ITU G.984 GPON (C+ Optics)

A customer has a backbone application for balanced twisted-pair cable that will require data to be
transmitted at 300 MHz. Which category/class of cable would meet these requirements? - Accurate
answers Category 6A/class EA

You are a designer at a telephone company. A new business in town wants to add a 6 Mb/s channel.
They are 11,729 feet from the central office. Which of the following is the best installation option for
these requirements? - Accurate answers Asymmetric digital subscriber line (ADSL)

What type of disturbance is created when inductive and capacitive circuits are switched on and off over
an operation cycle? - Accurate answers Electrical fast transient

, What type of energy has a frequency higher than the visible light? - Accurate answers Ultraviolet

An installation team is running a 600-pair category 3 cable from the first floor to the top floor of a
twenty-story building. The cable will be attached to a supporting strand that has been anchored in a
vertical shaft that runs the entire pathway. What is the minimum number of steel cable ties that should
be used to attach the category 3 cable to the support strand? - Accurate answers 60

A customer has 72 workstations that will be connected by multiuser telecommunications outlet
assemblies (MUTOAs). What is the minimum number of MUTOAs that will be needed to serve these
work areas? - Accurate answers 6

Which telecommunications administration class addresses the needs of a campus, including its buildings
and OSP elements? - Accurate answers Class 3

A trading floor has a HC (FD) 80 meters (262 ft) away from a MUTOA. What is the maximum length of
the work area cord? The work area cords are 24 AWG [0.51 mm (0.020 in)]. - Accurate answers 13
m (43 ft)

What is the center wavelength of a vertical cavity surface emitting laser (VCSEL)? - Accurate answers
850 nm and 1300 nm

Which of the following is an optional record for a Class 3 telecommunications system per the ANSI/TIA-
606-C standard? - Accurate answers Campus or site

You have been asked to review specifications for the conductors and protection devices for a project.
Upon calculating the information you notice that the feeder and branch circuits have been sized
correctly to support the non-continuous load plus: - Accurate answers 125% of the continuous load

Each DART automatically initiates and completes a test signal transmission sequence to its associated
DARR at least once every __ hours. - Accurate answers 24

What should be the minimum separation between the telecommunications cable and gas pipes when
they are running in parallel in a joint trench? - Accurate answers 305 mm (12 in)

The telephone company said they installed the new local telephone number on the 2nd pair of a T568A
jack labeled 235 V2 in office Room 285. What pins on the jack would you find the dial tone? - Accurate
answers Pins 3 and 6

What are the minimum dimensions for an entrance facility (EF) in a hospital? - Accurate answers
3.7 m by 4.3m (12ft by 14ft)

What type of coaxial connector should be used with an 11 GHz radio applications? - Accurate answers
N connector

Which of the following is the typical operating range for most audio equipment? - Accurate answers
10 Hz to 30 kHz
$23.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Studyglobal Yale University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
15
Miembro desde
1 año
Número de seguidores
0
Documentos
2532
Última venta
3 días hace
\"Study Smart, Anywhere, Anytime.\"

Welcome to StudyGlobal, where learning knows no borders. Whether you’re preparing for exams, mastering new subjects, or looking for efficient study strategies, StudyGlobal is here to help you succeed, no matter where you are in the world. At StudyGlobal, I am dedicated to providing students with the highest quality study materials that cater to diverse learning needs and academic goals. From in-depth notes and guides to concise summaries and exam prep resources, every piece of content is designed to help you study smarter and achieve your academic dreams. No matter where you’re from or what your educational background is, I want to make sure you have access to the best resources. That’s why I’ve made it my mission to curate study materials that are as global as the students who need them. Thank you for choosing StudyGlobal as your academic partner. I look forward to helping you reach your full potential and succeed on your academic journey.

Lee mas Leer menos
4.3

8 reseñas

5
6
4
0
3
1
2
0
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes