100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

NCTI MT1-MT2 Exam with complete solutions latest version.

Puntuación
-
Vendido
-
Páginas
12
Grado
A+
Subido en
12-09-2025
Escrito en
2025/2026

NCTI MT1-MT2 Exam with complete solutions latest version.

Institución
NCTI MT1-MT2
Grado
NCTI MT1-MT2

Vista previa del contenido

www.stuvia.com/doc

NCTI MT1-MT2 Exam with complete
solutions latest version



According to SCTE- and NCTA- recommended trunk system map symbols, fiber-
optic cable is represented by - CORRECT ANSWER-Double arrows within a small
circle on a solid line.

The forward path signal in a traditional tree-and-branch architecture - CORRECT
ANSWER-originates at the headend and is transmitted downstream through
coaxial trunk cable and trunk amplifier.

In a HFC network, - CORRECT ANSWER-Processing equipment in the headend
converts the forward RF signal to a light signal.

During aerial plant construction, - CORRECT ANSWER-The strand is tensioned so
its sag profile matches that of the overhead utility power lines.

With underground plant construction, - CORRECT ANSWER-The fiber-optic and
coaxial cables are often places underground with other utility lines to jointly
share construction costs.

Standby power supplies - CORRECT ANSWER-continue providing an output
voltage even during a utility power outage by using a back up power source.

Centralized power configurations - CORRECT ANSWER-provide the advantage of
increased reliability through sharing of expensive backup generators and
sophisticated monitoring equipment among different power realms.

When transmitting broadband signals - CORRECT ANSWER-In a two way hybrid
fiber/coax (HFC) network, two or more individual optical fibers are required for
each optical node location.

RF trunk amplifiers - CORRECT ANSWER-Have attenuator pads, equalizers, and
duplex filters that control and route the RF signals.

Verifying plant reliability includes - CORRECT ANSWER-Frequency response
sweeping, which is adjusting RF amplifier circuits to amplify all frequencies in the
bandpass spectrum as equally as possible

, www.stuvia.com/doc
Which of the following is a requirement in the process for measuring leakage
using a dipole antenna, as required by the FCC? - CORRECT ANSWER-The
antenna must be placed 3 meters from the system components and 3 meters from
the ground.

Many cable companies require which type of leaks to be fixed? - CORRECT
ANSWER-All types of leaks must be fixed.

According to the FCC, the leakage log should contain which of the following? -
CORRECT ANSWER-The probable cause of the leakage.

Which of the following FCC required information must a cable system keep on file
for two years? - CORRECT ANSWER-Annual CLI calculations, regular (quarterly)
monitoring programs, and a list of all channels used in the aeronautical bands.

If your leakage detector indicates there is a leak and displays a reading of 14
microvolts per meter (uV/m) when you are 80 feet from a possible leak source,
what is the approximate calculated level of the leak from 10 feet? - CORRECT
ANSWER-112 uV/m.

If a large signal leak is found in the aerial plant, what is a good first step in
locating the leak? - CORRECT ANSWER-Drive around until an absolute peak is
found.

Which of the following best describes demand maintenance procedures with
regard to signal leakage? - CORRECT ANSWER-The demand maintenance
procedures can improve the CLI measurement results by identifying and
correcting the largest leaks first.

When troubleshooting signal leakage in the drop system, what is indicated if all
signs of signal leakage disappear when the ground block is disconnected and
terminated on the side connected to the customer premises? - CORRECT
ANSWER-The backward route from the ground block to the tap can be eliminated
as a source of The backward route from the ground block to the tap can be
eliminated as source of leakage.

Which typical over-the-air signal sources can cause a false alarm with a signal
leakage detector? - CORRECT ANSWER-Typical sources include aircraft
communication signals and ham, mobile, and government radio broadcasts.

When adjusting or selecting the elements of a dipole antenna for measuring
signal leakage, what is the approximate length of each element relative to the
wavelength of the signal being measured? - CORRECT ANSWER-One-quarter
wavelength.

Which of the following problem(s) are caused by egress? - CORRECT ANSWER-
Interference with aeronautieal navigation
and communication, amateur radio public service, and cellular communications.

Escuela, estudio y materia

Institución
NCTI MT1-MT2
Grado
NCTI MT1-MT2

Información del documento

Subido en
12 de septiembre de 2025
Número de páginas
12
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$14.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
BRAINSCAPE1 Chamberlain College Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
126
Miembro desde
1 año
Número de seguidores
14
Documentos
11142
Última venta
1 mes hace
download to pass in your exam

**Profile: Exam and Flashcards Sales**. **Introduction:** Welcome to my profile! I specialize in providing comprehensive exam and flashcard resources tailored to meet your educational needs. With a dedication to quality and effectiveness, I aim to assist students in achieving their academic goals with ease and confide**Services Offered:** 1. **Exam Materials:**- I offer a wide range of exam materials for various subjects and levels, including standardized tests such as SAT, ACT, GRE, GMAT, TOEFL, and more- These materials are meticulously crafted to cover all exam topics comprehensively, ensuring thorough preparation and confidence on test day. 2. **Flashcards:** - My collection of flashcards is designed to facilitate efficient learning and retention of key concepts. - Each set of flashcards is carefully curated to highlight essential information, making studying more manageable and effective. **Why Choose Me:** 1. **Quality Assurance:** - I prioritize quality in all my products, ensuring accuracy, relevance, and reliability. - Every exam material and flashcard set undergoes rigorous review and updating to reflect the latest changes in curriculum and exam formats. 2. **User-Friendly Resources:** - My resources are user-friendly, featuring clear formatting, concise explanations, and intuitive organization to enhance the learning experience. - Whether you're a visual learner or prefer text-based study aids, my materials cater to diverse learning preferences. 3. **Affordability:** - I believe that access to quality educational resources should not be cost-prohibitive. Thus, I offer competitive pricing without compromising on quality.

Lee mas Leer menos
4.4

20 reseñas

5
12
4
5
3
2
2
0
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes