This document provides practice questions and answers for Underground Storage Tank (UST) compliance and certification exams. It covers key federal and state requirements including release detection, spill and overfill protection, cathodic protection, financial responsibility, secondary containment, tightness testing, site inspections, temporary and permanent closures, and recordkeeping. The material is structured in Q&A format, making it a comprehensive study resource for operator training and regulatory compliance preparation.

Vista previa del contenido

Underground Storage Tanks


A Class A operator shall maintain the records of UST Site Inspections for a minimum
of? - ANS - 3 Years

A leak should be suspected in a 1560-gallon tank if the variation between the beginning
and ending manual tank gauging liquid level measurements exceeds the weekly
standard of X gallons. X Is - ANS - 26 gallons

A Manual tank Guage Stick must be marked to the nearest - ANS - 1/8 Inch

A suspected release must be confirmed to the DEQ/LARA within: - ANS - 7 Days

After a UST is closed, how long must records be kept for? - ANS - at least 3 years.

An Automatic Tank Guage must be able to detect a leak of X Gallons per hour. X is? -
ANS - 0.2 Gallons per hour

API - ANS - American Petroleum Institute

ATG systems are equipt with what kind of alarms? - ANS - high and low product level,
high water level and theft

Automatic Line Leak detector may be used only if the method detects X Gallons per
hour at 10 lbs per square inch line pressure with in one hour. X is: - ANS - 3 Gallons
per hour

Automatic line leak detectors must be able to detect a leak X gallons per hour at a line
pressure of 10 psi within one hour. X is? - ANS - 3 gallons per hour

Automatic Tank Gauging System (ATG) - ANS - method that uses automated
processes to monitor product level and inventory level.

Ball Float valve - ANS - located at the bottom of the vent line, several inches below
the top of the UST...ball will rise with product level during delivery to restrict vapor
flowing out the vent line BEFORE the tank is full.

, Can a owner use pollution liability insurance as a means of financial responsibility? -
ANS - Yes

Check if the following statement is true or false: " A third part evaluation of a statistical
inventory reconciliation is good for any type of tank and product." - ANS - False

Class A and Class B Certification must be renewed every? - ANS - 5 Years

Class B operator shall not be responsible for more of the following facilities? - ANS -
45 facilities

continuous alarm system - ANS - constantly monitors line conditions and immediately
triggers an audible or visual alarm if a leak is suspected.

Even using the SIR system, you still have to do what everyday - ANS - product is
measured with gauge stick or other level monitor, and then reported when required.

Federal Regulation governing UST - ANS - 40 CFR 280

flow restrictor - ANS - if a leak is suspected it keeps the product flow rate well below
the usual flow rate.

Flow restrictors/flow shutoffs - ANS - monitor the pressure within the lines in different
ways. (Pressure up, down, how long it takes, etc.)

flow shutoff valve - ANS - if a leak is suspected it will completly cut off the flow and
shuts down the pump

For the SIR to be equivalent to the tank tightness testing, it must be able to detect to
what? - ANS - 0.1 gallons per hour.

How does the leak detection work with secondary containment method? - ANS - The
barrier holds the leak between the tank and the barrier so that the leak is detected. The
barrier is shaped so that a leak will be directed towards the interstitial monitor.

how long can a UST be temporarly closed for? - ANS - up to 12 months, then it must
be permanently closed

Información del documento

Subido en
9 de septiembre de 2025
Número de páginas
9
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$12.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
janenurse
4.1
(45)
Vendido
260
Seguidores
221
Artículos
2457
Última venta
2 meses hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes