IMSA Traffic Signal Technician 2 UPDATED ACTUAL Exam Questions and CORRECT Answers In a TS2 cabinet, how many times can the MMU experience a "Port 1 Fail" in a 24 hour period before the fault is latched? - CORRECT ANSWER - 1 On a 2070 MMU monitor unit, how does the field tech program allowable phases? - CORRECT ANSWER - Remove diode on program card for allowable phases

Mostrar más Leer menos
Institución
Imsa
Grado
Imsa









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Imsa
Grado
Imsa

Información del documento

Subido en
6 de septiembre de 2025
Número de páginas
13
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

IMSA Traffic Signal Technician 2
UPDATED ACTUAL Exam Questions and
CORRECT Answers
In a TS2 cabinet, how many times can the MMU experience a "Port 1 Fail" in a 24 hour period
before

the fault is latched? - CORRECT ANSWER -1


On a 2070 MMU monitor unit, how does the field tech program allowable phases? - CORRECT
ANSWER - Remove diode on program card for allowable phases


On an MMU, is it possible to tape the reset button to prevent the traffic signal from going into
flash? - CORRECT ANSWER - Yes, it by-passes the conflict feature and will not flash


On a NEMA CMU program card, how does the signal tech program allowable phases? -
CORRECT ANSWER - Install copper jumpers and soldering them on the program card


According to best maintenance practices, how often should CMU/MMU be tested? - CORRECT
ANSWER - Annually



The MMU indicates a RED-FAIL fault on phase 6. Why? - CORRECT ANSWER - The
load switch/switch pack produces no outputs.


The purpose of the controller CVM (Controller Voltage Monitor) output is to allow the
CMU/MMU to

monitor the - CORRECT ANSWER - Controller health


When a Technician is recertifying the CMU/MMU at an intersection, what should the technician
do to have the intersection exit flash? - CORRECT ANSWER - Replace the CMU/MMU
with a newly tested unit

, Absence of all colors on a load switch will be indicated by what fault on an MMU or MMU2? -
CORRECT ANSWER - Red Fail


Which of the following can be programmed on an MMU to latch after a fault occurs? -
CORRECT ANSWER - Field check



How often is an MMU's clock updated from the controller? - CORRECT ANSWER -
Once a second


In a signal cabinet, on the signal monitor, what does a field check indicate? - CORRECT
ANSWER - The signal indications don't match the controller output for a phase


A NEMA CMU/MMU uses a program card to tell the monitor which phases are permitted to run
together. Which answer is CORRECT? - CORRECT ANSWER - NEMA monitors have
wire jumpers missing in all positions, the tech solders the ones in that allow phases to run
together.


When the controller timings DO NOT match the timing sheet, who should be contacted for
correct

times? - CORRECT ANSWER - Traffic Engineer


An older TS1 cabinet experiences a flash condition but the signal heads are also showing active
green, yellow, and red indications. What is the MOST COMMON issue? - CORRECT
ANSWER - The mercury contactor is stuck in the normal position.


In a Dual-Ring, 8-phase traffic signal controller, how many phases can run in each ring at the
same

time? - CORRECT ANSWER -1


Observations indicate that vehicles are being detected in one lane and that this is shown on the
detection interface unit. However, the controller does not show any detection for that phase. This
$12.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
MGRADES Stanford University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1071
Miembro desde
1 año
Número de seguidores
102
Documentos
68976
Última venta
2 horas hace
MGRADES (Stanford Top Brains)

Welcome to MGRADES Exams, practices and Study materials Just think of me as the plug you will refer to your friends Me and my team will always make sure you get the best value from the exams markets. I offer the best study and exam materials for a wide range of courses and units. Make your study sessions more efficient and effective. Dive in and discover all you need to excel in your academic journey!

3.8

170 reseñas

5
73
4
30
3
45
2
8
1
14

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes