100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

HVAC EXCELLENCE NEWEST 2025/2026 ACTUAL EXAM COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+||BRAND NEW!!

Puntuación
-
Vendido
-
Páginas
7
Grado
A+
Subido en
06-09-2025
Escrito en
2025/2026

HVAC EXCELLENCE NEWEST 2025/2026 ACTUAL EXAM COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+||BRAND NEW!!

Institución
HVAC EXCELLENCE
Grado
HVAC EXCELLENCE

Vista previa del contenido

HVAC EXCELLENCE

- ANS-

____ may be used for leak detection with ALL high stress refrigerants - ANS-Soap Bubbles

10 lbs of refrigerant passing through a water cooled condenser will lose 20 BTU of heat/ pound.
If 10#'s of water passes thru the condenser with an entering temp of eighty levels, the temp of
the water leaving the condenser is - ANS-a hundred stages faranheit

A Compound stress gauge measures - ANS-Pressure and Vacuum

A compressor that has a broken reed valve will cause these symptoms - ANS-high suction
stress and coffee discharge pressure

A customer complains that their AC system is going for walks constantly, however no longer
cooling sufficient. The suction line could be very colde and the compressor is sweating.
Mostlikely reason is - ANS-a limit of the return air or grimy evaporator

A lower in superheat reasons the thermostatic growth valve to - ANS-Close

a grimy evaporator in an AC device will purpose those symptoms - ANS-low suction pressure
and occasional discharge pressure.

A drain lure must be set up on a cut up device while the - ANS-Air handler drain is at the bad
aspect

a faulty condenser fan motor on an AC gadget will reason these signs - ANS-excessive suction
stress and excessive discharge strain

A Liquid line filter drier should be located among the - ANS-Condenser and metering device

A liquid reciever is used to - ANS-Store liquid refrigerant

A liquid-to-suction warmness exchanger is often used to - ANS-Increase liquid subcooling

A low pressure reduce-off transfer is used to - ANS-Establish a minimum working stress inside
the evaporator

A low refrigerant charge in an AC gadget will reason these signs - ANS-low suction stress and
low discharge pressure

, A Mechanical shaft seal is necesssary on a - ANS-Open force compressor

a partially clogged capillary tube metering tool can cause - ANS-a starved evaporator

A partly iced over evaporator can be caused by - ANS-an undercharge

A refrigerant gives up heat whilst it; - ANS-it condenses

A refrigerant overcharge in a capillary tube aircon gadget will cause - ANS-High suction
pressure and excessive Discharge pressure

A rise in evaporator strain causes the automatic growth valve to start to - ANS-near

A scroll compressor moves refrigerant by means of; - ANS-involute spirals

A sight glass could generally be placed - ANS-inside the liquied line, earlier than the metering
device

A TEV sensing bulb which will become detached from the suction line will motive those signs
and symptoms - ANS-high suction pressure and higher than normal dischage strain

a thermal-electric powered ( strong country) growth valveis controlled via - ANS-NTC Thermistor

A thermostatic growth valve is designed to preserve - ANS-Constant evaporator superheat

After a device has been opened and the compressor modified, the carrier technician ought to: -
ANS-update the filter drier, leak test, evacuate and price

air or different non-condensable gasses in a capillary tube AC device will motive - ANS-High
suction stress and excessive discharge stress

an AC gadget this is oversized can motive - ANS-inefficient dehumidification of the conditioned
space

An accumulator is used to - ANS-Prevent liquid refrigerant from attaining the compressor

An automated enlargement valve is fine proper: - ANS-When the machine load stays pretty
consistent

An power restoration ventilator is - ANS-an air to air warmness exhanger to get better heat

an increase in head pressure reasons __ refrigerant to drift thru a capillary tube - ANS-More

Escuela, estudio y materia

Institución
HVAC EXCELLENCE
Grado
HVAC EXCELLENCE

Información del documento

Subido en
6 de septiembre de 2025
Número de páginas
7
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$15.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Legitexams Teachme2-tutor
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
60
Miembro desde
1 año
Número de seguidores
1
Documentos
1201
Última venta
1 día hace

Welcome To my Store My Goal is to help you achieve your desired grades by providing credible study materials I'm happy to help you with quality documents On this page you will find quality study guides, Exams assignments, Research papers and Test Banks all verified correct . you'll find past and recent revised and verified study materials . Stay here and You'll find everything you need to pass !!! . I always ensure my documents are of high standards Be assured to get good grades and always leave a review after a purchase Refer a friend SUCCESS!!!!

Lee mas Leer menos
3.2

25 reseñas

5
12
4
1
3
2
2
0
1
10

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes