PJM Generation Dispatcher Exam Questions and Answers||A+ Solution guide(Verified) Real time transmission constraints may be alleviated with generators operating - Answer- Off Cost (out of merit) What is the minimum size for a solar park to be required to have a real and reactive power telemetry? - Answer- 3MW PJM calls for which of the following to recover ACE so that tie line schedules are maintained? - Answer- Synchronized Reserves The minimum generation alert expires when? - Answer- It's cancelled by PJM When PJM declares a hot weather alert, the generation dispatcher should. - Answer- Determine if maintenance can be deferred During system restoration, the two categories of reserves are - Answer- Dynamic and Synchronous During system restoration, frequency should be maintained between - Answer- 59.75 and 61.00Hz PJM issues a heavy load voltage schedule. Member companies who own generation should: - Answer- Ensure voltage regulators on generating units are in service on automatic A unit being dispatched economically be PJM should set its MW output based on the - Answer- Unit's dispatch rate or desired MW level What hourly revenue data is required if a generator by PJM? - Answer- Compensated MWh delivered by each unit During system restoration prior to synchronization of a unit, the dispatcher should ensure sufficient load is available to - Answer- Stabilize unit operation A non-Zero ACE indicates: - Answer- An imbalance of generation and load During certain emergency conditions, a Capacity Performance generation resource that fails to generate the required amount of energy may be charged: - Answer- A non-performance assessment charge Control center facilities must have a minimum of how many days of fuel for the backup generator? - Answer- 3 days Which of the following one-way communication system is used to disseminate information to market operation centers? - Answer- All call Real time bus prices may be monitored using A. Data Viewer. B. eDART. C. InSchedule. D. Markets Gateway. - Answer- Data Viewer Which action is a violation of PJM two settlement market rules? - Answer- Not offering an available PJM capacity resource into the day ahead market A unit fails to start when scheduled, would be classified as which of the following types of outage? - Answer- Unplanned A forecasted planned outage starts a minimum of how many days into the future? - Answer- 31 days Maintenance outages are permitted when - Answer- A unit can be held online until the following Monday, and system reliability is not affected If PJM ACE shows overgeneration, actual imports are - Answer- Less than scheduled Who should a generator contact at PJM to clear an outage ticket? - Answer- Master Coordinator Which page in Markets Gateway is used to reflect real-time changes to unit status and output? - Answer- Unit Hourly Updates The loss of a large generation unit on the PJM system can be detected by monitoring what: - Answer- Frequency and PJM area control error. A 1000MW unit has tripped in the PJM control area and the the PJM ACE now indicates undergeneration of 1050MW. What immediate action should be taken by PJM to recover the ACE? - Answer- Request 100% synchronized reserves be loaded Which of the following emergency procedures are issued in advance of a scheduled load period to allow sufficient time for the generation dispatcher to prepare for the anticipated capacity shortages? - Answer- Alerts The amount of synchronized reserves must be large enough to cover the loss of - Answer- The largest single contingency PJM responds to capacity shortages by issuing alerts - Answer- In advance of a scheduled load period to allow sufficient time for members to prepare for anticipated initial capacity shortages.

Mostrar más Leer menos
Institución
PJM Generation Dispatcher
Grado
PJM Generation Dispatcher









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
PJM Generation Dispatcher
Grado
PJM Generation Dispatcher

Información del documento

Subido en
3 de septiembre de 2025
Número de páginas
5
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

PJM Generation Dispatcher Exam
Questions and Answers||A+ Solution
guide(Verified)
Real time transmission constraints may be alleviated with generators operating -
Answer- Off Cost (out of merit)

What is the minimum size for a solar park to be required to have a real and reactive
power telemetry? - Answer- 3MW

PJM calls for which of the following to recover ACE so that tie line schedules are
maintained? - Answer- Synchronized Reserves

The minimum generation alert expires when? - Answer- It's cancelled by PJM

When PJM declares a hot weather alert, the generation dispatcher should. - Answer-
Determine if maintenance can be deferred

During system restoration, the two categories of reserves are - Answer- Dynamic and
Synchronous

During system restoration, frequency should be maintained between - Answer- 59.75
and 61.00Hz

PJM issues a heavy load voltage schedule. Member companies who own generation
should: - Answer- Ensure voltage regulators on generating units are in service on
automatic

A unit being dispatched economically be PJM should set its MW output based on the -
Answer- Unit's dispatch rate or desired MW level

What hourly revenue data is required if a generator by PJM? - Answer- Compensated
MWh delivered by each unit

During system restoration prior to synchronization of a unit, the dispatcher should
ensure sufficient load is available to - Answer- Stabilize unit operation

A non-Zero ACE indicates: - Answer- An imbalance of generation and load

During certain emergency conditions, a Capacity Performance generation resource that
fails to generate the required amount of energy may be charged: - Answer- A non-
performance assessment charge

, Control center facilities must have a minimum of how many days of fuel for the backup
generator? - Answer- 3 days

Which of the following one-way communication system is used to disseminate
information to market operation centers? - Answer- All call

Real time bus prices may be monitored using A. Data Viewer. B. eDART. C.
InSchedule. D. Markets Gateway. - Answer- Data Viewer

Which action is a violation of PJM two settlement market rules? - Answer- Not offering
an available PJM capacity resource into the day ahead market

A unit fails to start when scheduled, would be classified as which of the following types
of outage? - Answer- Unplanned

A forecasted planned outage starts a minimum of how many days into the future? -
Answer- 31 days

Maintenance outages are permitted when - Answer- A unit can be held online until the
following Monday, and system reliability is not affected

If PJM ACE shows overgeneration, actual imports are - Answer- Less than scheduled

Who should a generator contact at PJM to clear an outage ticket? - Answer- Master
Coordinator

Which page in Markets Gateway is used to reflect real-time changes to unit status and
output? - Answer- Unit Hourly Updates

The loss of a large generation unit on the PJM system can be detected by monitoring
what: - Answer- Frequency and PJM area control error.

A 1000MW unit has tripped in the PJM control area and the the PJM ACE now indicates
undergeneration of 1050MW. What immediate action should be taken by PJM to
recover the ACE? - Answer- Request 100% synchronized reserves be loaded

Which of the following emergency procedures are issued in advance of a scheduled
load period to allow sufficient time for the generation dispatcher to prepare for the
anticipated capacity shortages? - Answer- Alerts

The amount of synchronized reserves must be large enough to cover the loss of -
Answer- The largest single contingency

PJM responds to capacity shortages by issuing alerts - Answer- In advance of a
scheduled load period to allow sufficient time for members to prepare for anticipated
initial capacity shortages.
$12.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Stuviaascorers University of Washington
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
346
Miembro desde
2 año
Número de seguidores
185
Documentos
10128
Última venta
4 días hace
StuviaAscorers | Top Study Notes & Exam Solutions

Stuviaascorers – Your #1 Source for Top-Quality Study Materials! Struggling with exams? Stuviaascorers has got you covered! I provide expertly crafted study notes, summaries, past papers, and exam-ready answers to help you pass with flying colors. My materials are designed for clarity, accuracy, and success—so you can study smarter, not harder! Why Choose My Study Materials? Well-structured & easy to understand – No fluff, just what you need! Exam-focused & high-scoring content – Get straight to the point! Accurate answers & clear explanations – Learn with confidence! Save time & boost your grades – Study efficiently! Don’t leave your success to chance! Browse my documents and start acing your exams today!

Lee mas Leer menos
3.8

64 reseñas

5
30
4
11
3
11
2
2
1
10

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes