100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

NFPA 54 Exam Questions and Answers 2025/2026 A+ Graded 100% Verified

Puntuación
-
Vendido
-
Páginas
8
Grado
A+
Subido en
29-08-2025
Escrito en
2025/2026

NFPA 54 Exam Questions and Answers 2025/2026 A+ Graded 100% Verified

Institución
NFPA 54
Grado
NFPA 54









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
NFPA 54
Grado
NFPA 54

Información del documento

Subido en
29 de agosto de 2025
Número de páginas
8
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

NFPA 54 Exam Questions and Answers
2025/2026 A+ Graded 100% Verified
NFPA 54 - ANS -National fuel gas code

Color use to identify natural - ANS -yellow

Specific gravity of gas - ANS -0.60 lighter then air

Elevated pressure of gas into a building - ANS -1/2 or 14 water column or greater

Ways to join gas pipe together - ANS -Weld, Threaded, Flared, Cast

Minimum gas piping size concealed - ANS -1/2

Minimum gas size buried - ANS -3/4

Gas pressure test for new pipe - ANS -3psi for 10 min

Gas pressure test for existing pipe - ANS -1 1/2 psi for 10 min

Never test Gas pipe - ANS -oxygen

test gauges calibrated - ANS -1/2 pound increments maximum 5 psi

Depth of a trench for gas - ANS -12 inch depth min, if hazards are found, 18 inches max

1 inch of mercury= - ANS -1/2 pound=

Components of natural gas - ANS -Methan 90%, Propane 5%, ethan 5%

Btu or British Thermal Unit - ANS -Amount of heat required to raise the temp of 1 pound
of water one degree Fahrenheit.

Ratio of air to natural gas for combustion - ANS -10 parts air to 1 part natural gas

In one cubic foot of gas there is - ANS -1,000 Btu's

Wire used under ground for gas - ANS -14 gauge tracer wire

, Distance between gas regulator and point of ignition - ANS -3 ft min

Pitch of gas pipe - ANS -1/4 per 15 ft

Plastic pipe for gas can only be used - ANS -Outside under ground and cannot penetrate
foundation or go under foundation.

Drip T's in gas lines must be placed - ANS -First change of direction after meter and at
any change of direction from horizontal to vertical.

Penetration of gas pipe through floors, patio or slab - ANS -No less then 2 inch of
unthreaded pipe.

All drip Tee's must have at least - ANS -3" between cap and tee.

Changing a chimerical gas stove with an exhaust hood is what must be done. - ANS -A
solenoid valve must be installed and wired to exhaust. If other units are present,
solenoids must be placed upstream of all fixtures.

Gas equipment shall not utilize any combustion air or ventilation air from - ANS
-Bedroom or bath room

Type 1 clothes dryers can be installed in closets in bed rooms or baths only when - ANS
-Combustion and ventilation air is introduced to the space with an air intake equal to or
greater then the size of the exhaust. The combustion and ventilation air must come from
a space that is sized correctly for combustion.

Gas flex hoses installled in industrial appliance - ANS -Shall not exceed 6ft

Direct gas fired Industrial Air Heaters may not be utilized unless manufacturer states that
there is no more then - ANS -50 ppm of carbon monoxide in total volume discharged
from unit

Room heaters shall not be installed - ANS -bathrooms or bed rooms unless they are
direct vented

unvented room heaters permits can not be given until - ANS -A permit is obtained from
fire department

Gas piping systems in excess of one million btu input shall be tested for a maximum of -
ANS -Not more than 24 hours

AWS - ANS -American Welding Society
$15.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
AVERYSELLER Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
265
Miembro desde
2 año
Número de seguidores
122
Documentos
3112
Última venta
2 semanas hace

3.8

40 reseñas

5
18
4
6
3
8
2
4
1
4

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes