100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

NAB NHA Exam 2026 Questions and Answers

Puntuación
-
Vendido
-
Páginas
122
Grado
A+
Subido en
28-08-2025
Escrito en
2025/2026

NAB NHA Exam 2026 Questions and Answers

Institución
NAB NHA
Grado
NAB NHA











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
NAB NHA
Grado
NAB NHA

Información del documento

Subido en
28 de agosto de 2025
Número de páginas
122
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

NAB NHA Exam 2026 Questions and
Answers

the physical plant - Correct Answer -all designed, constructed, equipped, and

maintained to protect health and safety of residents, personnel, public

Life Safety Code (LSC) - Correct Answer -Entire construction plan and materials

meet LSC standards|||CMS requires unless have waiver or exception. CMS grants

waivers on SNFs; states on NFs

(NFPA) - Correct Answer -National Fire Protection Association ||established LSC

Purpose of LSC - Correct Answer -to provide reasonable degree of safety from

fire.

Waivers for Life Safety Code - Correct Answer -If CMS finds a state fire and

safety code adequately protects residents and personnel thenLSC does not apply.

OLder facilities may obtain a waiver if they are and have been in compliance with

an older addition of LSC as specified by CMS.||Before a nursing home may be

built it must present architectural plant to State Medicaid or designated agency that

approves construction. All major renovations, such as additional beds, change in


©COPYRIGHT 2025 ALL RIGHTS RESERVED 1

,utilization of space, and so on must receive approval. The state provides guidelines

on what must be a approved. Upkeep and repairs do not require prior approaval.

Blue Prints - Correct Answer -keep as-built plans available for surveyors who do

LSC inspection as well as for repair persons who may need prints for big jobs.

LSC and other standards - Correct Answer -Building and contact standards are set

by LSC, CMS, ANSI/ADAAG - (dependent on which the state chooses) and state

and local codes. ||- for handicapped|-follow which on specific state requires

(ANSI/ADAAG)

LSC and ANSI/ADAAG - Correct Answer -LSC accepts both standards so they are

essentially all LSC standards. Administrator does not need to know EVERY

standard, but must keep a copy of the "LSC Handbook" as reference. The architect

who designs the facility must know and incorporate all LSC and other standards,

but it is advisable for the NHA to check his building to ensure compliance.

LSC, ANSI/ADAAG, and CMS - Correct Answer -**- building materials - fire-rate

according to number of stories. 2 hour and 1 hour rating|**- sprinklers - new

buildings have automatically activated by smoke/heat|- exits - no room more than

100 feet from exit. Lighted exit signs of specific size. |- walls extend continuously

to roof deck of next floor. wall finish must meet flame-spread requirements ( have

certificate of this)|- furnishings - curtains and carpet must meet fire rating|- rooms -

©COPYRIGHT 2025 ALL RIGHTS RESERVED 2

,CMS requirements - 4 residents to room MAX. 80 sq ft/resident (multi-resident

room), 100 sq ft for single occupancy.

requirement for rooms| - Correct Answer -- direct access to corridor|- outside

window (CMS) or door (LSC)|- privacy|- furnishing| separate bed, proper size and

height| bedding appropriate to climate| individual closet space| bedside table|

comfortable chair| enough overbid tables to meet needs of rsidents|- toilets (CMS,

ANSI, ADA)|- bathing facilities (CMS)|- resident call system (CMS, LSC) 24/7 -

back up system available|- temperature range (71-81 degree F) (three feet above

floor), states set actual, A/C not required

Doors - Correct Answer -All 44" or more in new construction (41.5

opening)|outside doors open egress.|no locks on resident door except staff has key

(LSC)||Bathroom door 32" (ANSI/ADAAG)||Fire Doors with automatic hold-open

devices required in corridors||(over bed tables not required for patient)

corridors - Correct Answer -no dead-ends (LSC)||8 feet wide (CMS)

Floors - Correct Answer -at or above ground level. (LSC) |Fire rating if carpeted.

(LSC)|Non-slip bath/toilet (ANSI, LSC)|Asphalt tile best

Fire alarms - Correct Answer -flashing and audible. |connect with local fire dept, if

possible|must have NFPA 71 certification of fire alarm service|



©COPYRIGHT 2025 ALL RIGHTS RESERVED 3

, smoke detectors - Correct Answer -approved detectors requried

smoking - Correct Answer -written regulations, enforced. |smoking ares with non-

combustible ashtrays, metal containers with self-closing lids.|Prohibited areas

include resident rooms and beds, oxygen, flammable liquid storage.|proper signs

posted.|supervise non-responsible.

ANSI/ADAAG(Americans with Disabilties Act Accessibility Guidelines) - Correct

Answer -Make building available to and usable by physically handicapped, no

mental (blind, deaf, non-ambulatory, semi-ambulatory, uncoordinated). ADAAG =

MAKE BUILDINGS AVAILABLE TO ADA'S. |State decides whether to apply

ANSI or ADAAG standards to nursing homes

accessible route - Correct Answer -no incline more than 10%

Wheelchair passage - Correct Answer -32" bathroom doors||36" elsewhere

parking - Correct Answer -13 FEET||cannot block sidewalk; alley for 2 cars.|The

number of handicap parking places is determined from a grid issued by ANSI. It

MUST BE NOTED THAT FOR EVERY EIGHT (8) HANDICAP PARKING

SLOTS, ONE MUST BE VAN ACCESSIBLE.||If the facility only has one

handicapped place, it must be van accessible.

ramps - Correct Answer -maximum rise 30". Slope not more than 1:10


©COPYRIGHT 2025 ALL RIGHTS RESERVED 4
$13.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
EmillyCharlotte Howard Community College
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
98
Miembro desde
1 año
Número de seguidores
5
Documentos
12005
Última venta
2 semanas hace
ALL-MAJOR.

On this page, you find all documents, package deals, and flashcards offered by seller Emilly Charlotte.

3.5

21 reseñas

5
7
4
6
3
2
2
3
1
3

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes