100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

Audiology Exam 3 ACTUAL UPDATED Exam Questions and CORRECT Answers

Puntuación
-
Vendido
-
Páginas
6
Grado
A+
Subido en
26-07-2025
Escrito en
2024/2025

Audiology Exam 3 ACTUAL UPDATED Exam Questions and CORRECT Answers SDT: Speech Detection Threshold - CORRECT ANSWER - Definition: the lowest level in dB that a person can just detect the presence of speech and identify it as speech 50% of the time -helpful when working with infants and uncooperative children (reduced cognitive function) -usually 2 syllable words as stimulus -not popular due to lack of relevant info (really just a screening for further testing) *aka Speech Awareness Threshold (SAT) SRT Method - CORRECT ANSWER - Bracketing technique: bracket until 3 correct responses have been obtained at a given level -most use because requires no knowledge of other results, involves use of up 5/down10 ste

Mostrar más Leer menos
Institución
Audiology
Grado
Audiology

Vista previa del contenido

Audiology Exam 3 ACTUAL UPDATED
Exam Questions and CORRECT Answers
SDT: Speech Detection Threshold - CORRECT ANSWER - Definition: the lowest level in
dB that a person can just detect the presence of speech and identify it as speech 50% of the time
-helpful when working with infants and uncooperative children (reduced cognitive function)
-usually 2 syllable words as stimulus
-not popular due to lack of relevant info (really just a screening for further testing)
*aka Speech Awareness Threshold (SAT)


SRT Method - CORRECT ANSWER - Bracketing technique: bracket until 3 correct
responses have been obtained at a given level
-most use because requires no knowledge of other results, involves use of up 5/down10 steps
(same as pure tone)


SRT Purpose - CORRECT ANSWER - -basis for Word Recognitions testing
-check on pure tone results (can be predicted form PTA; This = PTA + or - 6 dB)
-categorize hearing loss
-help with judgements as needed for amplification
-used in hearing aid evaluation to determine correct amount of gain


SRT: Speech Recognition Threshold - CORRECT ANSWER - -defined as lowest level in
dB that a person can correctly identify the speech stimuli 50% of the time
-Hudgins et. al (words should satisfy-familiarity, phonetic dissimilarity, normal sampling of
English language, and homogeneity (audibility)
-36 two syllable words (spondaic words/spondees-airplane, toothbrush, sidewalk, hotdog, etc.)
*aka Speech Reception Threshold


MCL: Most Comfortable Loudness Level - CORRECT ANSWER - -intensity level that a
person perceives as comfortable to listen to

, -Stimulus is cold running speech (informative but non-emotional recorded at constant level)
-usually 40-50dB sensation level
-can be slightly hard for patient to identify, so results can vary 5-10dB on the high or low side, so
bracketing method used to find
-found monaurally, binaurally, or in sound field


MCL Purpose - CORRECT ANSWER - to determine the best level for the patient to hear
and understand speech (or, intensity level that a person perceives as comfortable to listen to (not
too soft or loud)
-most often used in evaluation of hearing aids


MCL Method - CORRECT ANSWER - -bracketing method used to find (can be hard for
patient to identify, so results can vary 5-10dB on the high or low side) (bracket until 3 correct
responses have been obtained at a given level)
-after instructions, start bracketing level by starting with stimulus below comfortable listening
level (too soft-usually 40 dB SL or 40 dB above SRT)-instruct patient to raise thumb when needs
to be increased
-continue cold running speech and quickly increase in 5dB steps until speech presented is above
threshold but just below uncomfortable level
-thumb down for softer, decrease speech in 10 dB until comfotable (forced choice method)
-OR, loudness chart use (1-7)


Loudness Discomfort Level (LDL) - CORRECT ANSWER - -the point where the speech
becomes uncomfortably loud
-usually 100-110 dB HL in normal hearing patients
-stimulus is cold running speech
-hearing losses don't necessarily extend this
*aka UCL (uncomfortable loudness level), ULCL (upper level of comfortable listening), ULC
(upper level comfort), HCL (highest comfort level)


LDL Purpose - CORRECT ANSWER - to determine the point where no further loudness
will be accepted by the patient

Escuela, estudio y materia

Institución
Audiology
Grado
Audiology

Información del documento

Subido en
26 de julio de 2025
Número de páginas
6
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$11.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
MGRADES Stanford University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1141
Miembro desde
2 año
Número de seguidores
104
Documentos
69677
Última venta
9 horas hace
MGRADES (Stanford Top Brains)

Welcome to MGRADES Exams, practices and Study materials Just think of me as the plug you will refer to your friends Me and my team will always make sure you get the best value from the exams markets. I offer the best study and exam materials for a wide range of courses and units. Make your study sessions more efficient and effective. Dive in and discover all you need to excel in your academic journey!

3.8

180 reseñas

5
78
4
31
3
47
2
9
1
15

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes