100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

Wastewater Collection with correct answers

Puntuación
-
Vendido
-
Páginas
7
Grado
A+
Subido en
18-07-2025
Escrito en
2024/2025

Wastewater Collection with correct answers

Institución
Wastewater Collection Grade 3
Grado
Wastewater collection grade 3









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Wastewater collection grade 3
Grado
Wastewater collection grade 3

Información del documento

Subido en
18 de julio de 2025
Número de páginas
7
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Wastewater Collection with correct
answers




60 gallons per hour is equal to - CORRECT ANSWER-1 gallon per minute.

The slope of a sewer is measured by the difference in - CORRECT ANSWER-Invert
elevations over a length of pipe

An air gap can be used to prevent.... - CORRECT ANSWER-backflow of waste water
into a drinking water supply.

A cross connection is a potable water pipe connected to a supply of... - CORRECT
ANSWER-questionable origin.

Wastewater carried in to a collection system may come from - CORRECT ANSWER-
Inflow

When using any hydraulic sewer cleaning method care must be taken by the operator
not to - CORRECT ANSWER-Cause flooding in home and businesses.

Disease producing bacteria are - CORRECT ANSWER-Called Pathogenic.

A man hole with the center great is normally used for - CORRECT ANSWER-Storm
sewer.

A Polly Pig would be used as a - CORRECT ANSWER-Reamer.

A minimum scouring velocity of 2ft/sec in sewers is necessary so that solids.... -
CORRECT ANSWER-won't build up in a sewer and reduce flow.

A cross-connection is best defined as? - CORRECT ANSWER-A potable water supply
connected to a potential source of pollution.

When dealing with collection systems, I&I refers to - CORRECT ANSWER-Infiltration
and Inflow

, Corrosion of sewer pipes maybe caused by - CORRECT ANSWER-Acids in water

In a collection system, waste water that contains NO "FREE" or dissolved oxygen is
referred to as - CORRECT ANSWER-Anaerobic .

The primary reason why it is important not to have cross connections of sewer with
water supply systems is? - CORRECT ANSWER-Possible water contamination .

A Polly Pig would most likely be used in the cleaning of a - CORRECT ANSWER-Force
main.

Flow rates can be expressed in - CORRECT ANSWER-Units of MGD [L/S] = Million
gallons per day 1.547 cu ft/s

A sewer man hole is an.... - CORRECT ANSWER-opening in a sewer provided for the
purpose of access.

The crown of a sewer pipe is called - CORRECT ANSWER-The top.

The primary purpose of wastewater disinfection is prevention.... - CORRECT ANSWER-
of receiving water contamination.

What should be considered as the scouring velocity of sanitary sewer - CORRECT
ANSWER-2 ft/second

A manhole barrel is referred to as - CORRECT ANSWER-The cylindrical section
between the cone and shelf.

What does not lead to roots entering a collection system manhole - CORRECT
ANSWER-Walls properly sealed.

Sewer lines can move after years in place due to - CORRECT ANSWER-Settlement,
frost action, nearby activities.

The end of the sewer pipe that is formed to fit into the bell of the next pipe is called -
CORRECT ANSWER-Spigot.

The components of a manhole are - CORRECT ANSWER-Cone, barrel, shelf.

When the velocity of flow in a collection system is 2 ft./sec or greater - CORRECT
ANSWER-A scouring action will develop.

Inflow can best be defined as? - CORRECT ANSWER-Direct discharge of stormwater
to a sewer.
$10.39
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
constantinelyketsos

Documento también disponible en un lote

Conoce al vendedor

Seller avatar
constantinelyketsos Chamberlain College Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
6
Miembro desde
5 meses
Número de seguidores
9
Documentos
1238
Última venta
4 días hace
Nursing study hub

welcome to my store high quality study notes ,summeries ,and guides to hep student understand faster and achieave better grades.

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes