IICL Container Inspector's Exam 2025
|Real Questions With Verified Answers
Envelope Damage Criteria - correct -answer-Envelope damage criteria
are commonly used for out-of-ISO and into-cube damages.
Envelope damage criteria are based on allowing a component to deflect
any amount provided the component stays within a reference plane or
between a set of reference planes. The reference planes are usually planes
that form an envelope on one or both sides of the component. The
reference planes are often not physical surfaces on the container. Instead,
they are virtual planes positioned in space a specified distance from
physical surfaces on the container. When a component is permanently
deflected beyond the reference plane, repair is required.
All rails, including side rails, headers and sills // Repair if.... - correct -
answer-Holed, cut torn or cracked; broken component and/or weld //
Missing or loose parts or fasterners
Top side rails // Repair if - correct -answer-Any deformation such as bend,
bow, dent, etc..
Front and rear headers // Repair if - correct -answer-Any deformation such
as bend, bow, dent, etc (IF more than 35 mm (1-3/8 in) deep, EXCEPT on
a header extension plate or corner protection plate
Bottom side rails, front and door sills (Any deformation such as bend, bow,
dent, etc. ON A WEB) // Repair if - correct -answer-More than 50 mm (2
in) deep
,2|Page
Bottom side rails, front and door sills (Any deformation such as bend, bow,
dent, etc. ON A FLANGE) // Repair if - correct -answer-torn, cracked or
cut
Door headers and sills // Repair if - correct -answer-Interference with door
closure, securement and/or not light-tight
All corner posts, including j-bars // Repair if - correct -answer-Holed, cut,
torn or cracked; broken component and/or weld
All corner posts, front and rear (Any single deformation such as bend, bow,
dent, etc.) // Repair if - correct -answer-more than 20 mm (13/16 in),
regardless of length or location
All corner posts, front and rear (OUTWARD deformation.) // Repair if -
correct -answer-more than 5 mm (3/16 in) beyond plane of end surfaces
or 10 mm (3/8 in) beyond plane of side surfaces of corner fittings
Rear corner posts // Repair if - correct -answer-Any deformation causing
interference with door operation, securement or light-tightness
J-bars // Repair if - correct -answer-Any deformation such as bend, bow,
dent, etc. // Door must be able to open fully (270 degrees)
All side/front panels // Repair if - correct -answer-Holed, cut, torn or
cracked; broken component and/or weld
Missing or loose parts or fasteners
INWARD deformation such as bend, dent, etc. (if more than 35 mm (1-3/8
in), measured on an exterior recessed corrugation)
,3|Page
Side panels // Repair if - correct -answer-OUTWARD deformation, such
as bend, bow, dent, etc. (If more than 30 mm (1-3/16 in) measured on an
inside recessed corrugation)
Front panels // Repair if - correct -answer-OUTWARD deformation, such
as bend, bow, dent, etc. (If more than 15 mm (9/16 in) measured on an
inside recessed corrugation)
Ventilator covers // Repair if - correct -answer-Broken, missing, etc. (If
cracked or broken in the enclosed, baffled area of the ventilator)
Door assembly, including hardware // Repair if - correct -answer-Holed,
cut, torn or cracked; browken component and/or weld
Missing or loose parts or fasteners
Any deformation such as bend, bow, dent, etc (If door operation or
securement is impaired)
Seized, frozen or stiff (If door operation or securement is impaired)
Not light-tight
Door panels // Repair if - correct -answer-Any deformation such as bend,
dent, etc (If internal cube intrusion is greater than 35 mm (1-3/8 in))
Door gaskets // Repair if - correct -answer-Loose or missing
Cut, torn, cracked or burned (If not light-tight or if the outer lips of the top
horizontal gaskets are not fully in place and seated against the header)
, 4|Page
Roof panels, header extension plates, and corner protection plates //
Repair if - correct -answer-Holed, cut, torn or cracked; broken component
and/or weld
Corner protection plates and header extension plates // Repair if - correct -
answer-Any deformation such as bend, bow, dent, etc. (IF more than 40
mm (1-9/16 in) below top surfaces of top side rails)
All roof panels (DOWNWARD) deformation such as bend, dent, etc. //
Repair if - correct -answer-IF more than 40 mm (1-9/16 in ) below top
surfaces of top side rails
All roof panels (UPWARD) deformation such as bend, dent, etc. // Repair if
- correct -answer-IF more than 40 mm (1-9/16 in ) above top surfaces of
top side rails
Floor and center rail // Repair if - correct -answer-If light leaks, regardless
of diameter or hole
Broken component and/or weld; missing, loose or protruding fasteners
Light leakage gaps between boards
Wooden flooring // Repair if - correct -answer-Delamination or splinters
DOWNWARD deformation such as a bend or bow (IF more than 15 mm
measured transversely at the floor screw center line)
Wooden flooring (Gouges) // Repair if - correct -answer-IF more than 15
mm (9/16 in) deep OR more than 5 mm (3/16 in) deep throughtout a width
of more than 150 mm (6 in) of the gouge